Range of supply and  device application   

 

Standard range of supply:

 

 
O2 measuring device type 

 OXI

- 1 pc

 

Connecting hoses lenght 1 m- 2 pcs                                                                                            
Rechargeable adapter 24 V DC/200 mA – 1 pc 

 

Optional accesories:  

DVD with SerialWatcher programme  to display the measured data in PC- 1pc 
cable RS485/USB  FTDI USB-RS485-WE-1800-BT for connection to PC - 1 pc 
USB-RS485 ModBus Converter- 1 pc 
Sampler ICAS1 – for glass bottles and adapter  ICAS1- for plastic bottles. 
Sampler ICAS2-for sampling  of hopped wort  from fermenting tank 
Adapter for easi and reliable connection of oximeter to the sampling point on the piping (technology) 
Reduction for hoses with different diameters 
 OXI holder 

 

Note:   accessories is not part of the supply - only on customer’s demand 
 
Measuring device for measurement of O2 content in beverages and gases especially in beer, soft drinks and wine. 
Check the possibility for O2 measurement in other beverages and gases with manfacturer. 
It is portable   device that can be firmly  built-in with  the help of the supplied  holder. 
It is equipped with the internal memory with capacity of 450 measured values. Measured values can be transferred 
into PC with the help of RS485/USB adapter and then exported to Excell for further processing. Measurement period 
can be easily adjusted.  
 

Note: 

Adapted only for industrial application  

 

 

2. Installation - putting the device into operation  

 

2.1 TAKING OF SAMPLES: 

The device is ready for measurement at the moment of delivery. 
Before the measurement connect the device by fixing of inlet hose with the connection (4) on oximeter (see pic.2) to 
the  sampling  point.  In  case  it  is  not  possible  to  connect  the  inlet  hose  to  the  sampling  point  please  use  the 
corresponding reduction – attach the corresponding hose to the reduction to take safely the sample. The inlet hose 
(3) must be secured at the sampling point not to fall out during taking of sample.  
Connect the reduction (1) with the help of the outlet hose (5) and place it to the drain. Hold the device in a horizontal 
position  during  filling  the  measuring  chamber  (see  pic.2)  –  connection  (1)  is  oriented  up.  Measured  liquid  goes 
through  the inlet hoses into the measuring chamber (3) where O2 content is measured with measuring electrode (5). 
Then the measured liquid goes out of the chamber through the outlet hose.  Adjust the flow rate by control valve (2) 
in the way to avoid bubles creation. 
 

2.2 CLEANING OF THE DEVICE: 

Connect the device by fixing of inlet hose with the connection (4) on oximeter (see pic.2) to the water cock.  In case 
it  is  not  possible  to  connect  the  inlet  hose  to  the  water  cock  please  use  the  corresponding  reduction  –  attach  the 
corresponding  hose  to  the  reduction.  The  inlet  hose  on  the  water  cock  (3)  must  be  secured  not  to  fall  out  during 
rinsing. Place the outlet hose into the drain and open the control valve (2). Wash water goes through   inlet hose to 
the  measuring  chamber  (3)  and  then  it  goes  out  of  the  chamber  through  the  outlet  hose  to  the  drain.      Once  the 
cleaning is over switch off  the water cock. Disconnect the device from the water cock and let the water go out from 
the measuring chamber. 
Clean  the  external  surface  with  soft  flannel  moistened  with  water.  After  this  handling  the  device  is  ready  for  next 
measurement. 
 
 
.  
 

Summary of Contents for OXI

Page 1: ...GEN MEASURING DEVICE USER S GUIDE Contents 1 Range of supply and device application 2 Installation putting the device into operation 3 Safety recommendations 4 Technical data 5 Operating instructions 6 Service changing the O2 cap refuse disposal 7 Installation of communication program into PC and measured data transfer ...

Page 2: ... of inlet hose with the connection 4 on oximeter see pic 2 to the sampling point In case it is not possible to connect the inlet hose to the sampling point please use the corresponding reduction attach the corresponding hose to the reduction to take safely the sample The inlet hose 3 must be secured at the sampling point not to fall out during taking of sample Connect the reduction 1 with the help...

Page 3: ...rages and gases with manfacturer Check device before each measurement Do not use visibly damaged device Notice Remove sludge from the sampling point before connecting the device Remove sludge of the sedimented yeast to fill inside the chamber only beer without sedimented yeast Before the measurement connect the device by fixing of inlet hose with the connection 4 on oximeter see pic 2 to the sampl...

Page 4: ... water cock Disconnect the device from the water cock and let the water go out from the measuring chamber Clean the external surface with soft flannel moistened with water After this handling the device is ready for next measurement 5 2 CONTROL OF THE ELECTRONICS The device i e switch on shutdown measurement saving of the measured sample in the memory is controlled with the help of the membrane ke...

Page 5: ... the running period and the accumulator life time will be shortened too Once the charging of the device is over unplug the adaptor and the opposite connector of the adaptor from the connector on the device At the end screw fully the connector cover on the device 5 2 3 O2 CONTENT MEASUREMENT Follow the paragraphs 5 1 1 then further 1 Press the key ON to switch on the device The text 1 CUBE with the...

Page 6: ...mory 1 Press the key ON to switch on the device The text 1 CUBE with the program version appears on the display for a moment Then the following text appears ENT meas view 2 Press the key mínus Then the following text appears memory deleting And all the saved values are overwritten with number 65535 free capacity of the memory 5 2 6 REPLACEMENT OF BATTERIES 1 unscrew as shown below 2 Pull the eleme...

Page 7: ...com At the end of the apparatus life we recommend to follow the Waste Act The electronic parts has to be destroyed separately by a company dealing with electronic waste disposal Take the metallic parts made of iron brass plastic elements and packing material to the separated collection as a secondary raw material You can also order the apparatus liquidation at the above mentioned company ...

Page 8: ...6 1 CHANGING THE O2 SENSOR CAP Loosen the connector 7 and unscrew O2cap 5 from the measuring chamber 3 see pic 2 ...

Page 9: ...6 8 9 Legend 1 Outlet hose reduction 2 Control valve 3 Measuring chamber 4 Intlet hose reduction 5 O2 Electrode 6 Keyboard with display see pic 1 7 O2 Electrode Connector 8 Oximeter body with microcomputer 9 Connector input see pic 4 ...

Page 10: ...Pic 3 Set Oxi hopped wort measurement 1 ICAS 2 4 Legend 1 Outlet hose reduction 4 Intlet hose reduction ...

Page 11: ... 1 CUBE with the program version appears on the display for a moment Then the following text appears memory view 4 Press the key plus There is text memory on the first line and the measured O2 values appear one by one from the oldest to the newest ones on the second line At the same time these values are displayed in SerialWatcher program Windows in column one by one from the oldest value to the n...

Reviews: