Chapter 24 Multicast
XS1920 Series User’s Guide
198
The following table describes the fields in the above screen.
Table 88
Advanced Application > Multicast > IPv6 Multicast > MLD Snooping-proxy > VLAN
LABEL
DESCRIPTION
VID
Enter the ID number of the VLAN on which you want to enable MLD snooping-
proxy and configure related settings.
Upstream
Query Interval
Enter the amount of time (in miliseconds) between general query messages sent
by the router connected to the upstream port. This value should be exactly the
same as what’s configured in the connected multicast router.
This value is used to calculate the amount of time an MLD snooping membership
entry (learned only on the upstream port) can remain in the forwarding table.
When an MLD Report message is received, the Switch sets the timeout period of
the entry to be T = (QI*RV) + MRD, where T = Timeout, QI = Query Interval, RV
= Robustness Variable, and MRD = Maximum Response Delay.
Maximum Response Delay
Enter the amount of time (in miliseconds) the router connected to the upstream
port waits for a response to an MLD general query message. This value should
be exactly the same as what’s configured in the connected multicast router.
This value is used to calculate the amount of time an MLD snooping membership
entry (learned only on the upstream port) can remain in the forwarding table.
When an MLD Report message is received, the Switch sets the timeout period of
the entry to be T = (QI*RV) + MRD, where T = Timeout, QI = Query Interval, RV
= Robustness Variable, and MRD = Maximum Response Delay.
When an MLD Done message is received, the Switch sets the entry’s lifetime to
be the product of
Last Member Query Interval
and
Robustness Variable
.
Robustness Variable
Enter the number of queries. A multicast address entry (learned only on an
upstream port by snooping) is removed from the forwarding table when there is
no response to the configured number of queries sent by the router connected to
the upstream port. This value should be exactly the same as what’s configured in
the connected multicast router.
This value is used to calculate the amount of time an MLD snooping membership
entry (learned only on the upstream port) can remain in the forwarding table.
Last Member Query
Interval
Enter the amount of time (in miliseconds) between the MLD group-specific
queries sent by an upstream port when an MLD Done message is received. This
value should be exactly the same as what’s configured in the connected
multicast router.
This value is used to calculate the amount of time an MLD snooping membership
entry (learned only on the upstream port) can remain in the forwarding table
after a Done message is received.
When an MLD Done message is received, the Switch sets the entry’s lifetime to
be the product of
Last Member Query Interval
and
Robustness Variable.
Downstream
Query Interval
Enter the amount of time (in miliseconds) between general query messages sent
by the downstream port.
Maximum Response Delay
Enter the maximum time (in miliseconds) that the Switch waits for a response to
a general query message sent by the downstream port.
Add
Click this to create a new entry or to update an existing one.
This saves your changes to the Switch’s run-time memory. The Switch loses
these changes if it is turned off or loses power, so use the
Save
link on the top
navigation panel to save your changes to the non-volatile memory when you are
done configuring.
Cancel
Click
Cancel
to reset the fields to your previous configuration.
Содержание XS1920 Series
Страница 18: ...18 PART I User s Guide ...
Страница 32: ...32 PART II Technical Reference ...
Страница 171: ...Chapter 21 Classifier XS1920 Series User s Guide 171 Figure 119 Advanced Application Classifier Configuration ...
Страница 177: ...Chapter 21 Classifier XS1920 Series User s Guide 177 Figure 122 Classifier Example EXAMPLE ...
Страница 209: ...Chapter 24 Multicast XS1920 Series User s Guide 209 Figure 143 MVR Group Configuration Example EXAMPLE ...
Страница 383: ...Chapter 50 Configure Clone XS1920 Series User s Guide 383 Figure 273 Management Configure Clone ...
Страница 408: ...Appendix C IPv6 XS1920 Series User s Guide 408 ...
Страница 412: ...Appendix D Legal Information XS1920 Series User s Guide 412 Environmental Product Declaration ...