![ZyXEL Communications U-1496 series Скачать руководство пользователя страница 32](http://html1.mh-extra.com/html/zyxel-communications/u-1496-series/u-1496-series_user-manual_944648032.webp)
CELL 9600 AT&N44 CELL 9600
CELL 7200 AT&N45 CELL 7200
CELL 4800T AT&N46 CELL 4800T
CELL 4800C AT&N47 CELL 4800C
CELL 3600C AT&N48 CELL 3600C
CELL 2400C AT&N49 CELL 2400C
Note: @: All ZyX modes except ZyX 16800 are available only on
Plus models.
QUALITY ACTION
AUTO RETRAIN AT*Q1 When poor signal quality is
detected, automatically retrain. S41.2=1 extends retrain time
out to 5 minutes.
+ ADAPTIVE RATE AT*Q2 When poor signal quality is
detected, automatically fall-back to next lower speed. When
signal quality is improved, automatically fall-forward to next
higher speed. Rate range 19200 bps - 4800 bps.
DISCONNECT AT*Q3 When poor signal quality is
detected, modem disconnects itself.
NO RESPONSE AT*Q0 No response to poor signal quality.
DEFAULT DIAL
PH0-PH9 AT*D0-9 Default dial pointer. The first phone
number displayed in DIAL MEMORY menu (default is PH0). If DTR
option 108.1 is active, DTR OFF-ON transition will cause modem to
dial the number stored in the memory address selected (memory
address 0 to 9).
(See also S35b4).
DIAL BACKUP
+ DISABLED AT*B0 Leased line dial backup disabled.
PH0-PH8 AT*B1-9 When Leased line cannot to continue
operation, the originate mode modem will automatically dial the
number stored in the memory address selected. The answer mode
modem also needs to select a non-zero memory address to enable
answering at the dial-up line during dial backup. (See also
S44b2).
GUARD TONE
(for V.22 and V.22bis answer mode operation)
+ NONE AT&G0 No guard tone provided.
RESERVED AT&G1 Reserved.
1800 HZ AT&G2 1800 Hz guard tone provided.
RDL REQUEST
GRANT AT&T4 Accepts remote digital loopback test
request from remote modem. Must be set when remote configuration
is needed.