231
5.4.51 VLANs Ports
Object
Description
VLAN User
Various internal software modules may use VLAN services to configure VLAN port
configuration on the fly.
The drop-down list on the right allows for selecting between showing VLAN
memberships as configured by an administrator (Admin) or as configured by one of
these internal software modules.
The "Combined" entry will show a combination of the administrator and internal
software modules configuration, and basically reflects what is actually configured in
hardware.
If a given software modules hasn't overridden any of the port settings, the text "No
data exists for the selected user" is shown in the table.
Port
The logical port for the settings contained in the same row.
Port Type
Shows the port type (Unaware, C-Port, S-Port, S-Custom-Port.) that a given user
wants to configure on the port.
The field is empty if not overridden by the selected user.
Ingress Filtering
Shows whether a given user wants ingress filtering enabled or not.
The field is empty if not overridden by the selected user.
Frame Type
Shows the acceptable frame types (All, Taged, Untagged) that a given user wants to
configure on the port.
The field is empty if not overridden by the selected user.
Port VALN ID
Shows the Port VLAN ID (PVID) that a given user wants the port to have.
The field is empty if not overridden by the selected user.
Tx Tag
Shows the Tx Tag requirements (Tag All, Tag PVID, Tag UVID, Untag All, Untag PVID,
Untag UVID) that a given user has on a port.
The field is empty if not overridden by the selected user.
Untagged VLAN ID
If Tx Tag is overridden by the selected user and is set to Tag or Untag UVID, then this
field will show the VLAN ID the user wants to tag or untag on egress.
The field is empty if not overridden by the selected user.
Conflicts
Two users may have conflicting requirements to a port's configuration. For instance,
one user may require all frames to be tagged on egress while another requires all
Содержание RGS Series
Страница 7: ...7 Preface Scope Audience Safety Instructions Documentation Conventions ...
Страница 9: ...9 Overview Overview Faceplate Panel Introduction ...
Страница 13: ...13 Quick Installation Equipment Mounting Cable Connecting Equipment Configuration ...
Страница 18: ...18 Figure 6 RGS200 12P Series Ground Connections ...
Страница 36: ...36 5 2 1 Configuration Menu ...
Страница 37: ...37 5 2 2 Monitor Menu ...
Страница 38: ...38 5 2 3 Diagnostics Menu 5 2 4 Maintenance Menu ...
Страница 54: ...54 5 3 12 Privilege Level This page provides an overview of the privilege levels ...
Страница 61: ...61 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 104: ...104 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 110: ...110 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 127: ...127 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 150: ...150 Buttons Click to apply changes Click to undo any changes made locally and revert to previously saved values ...
Страница 169: ...169 5 3 80 Port Config This page allows you to enable a port for GVRP Buttons Click to apply changes ...
Страница 238: ...238 Click to re start diagnostics with PING ...
Страница 252: ...252 台灣 警告使用者 ...