background image

ZyXEL Confidential 

340ST5C0.doc 

17/25

 

memwrite 

 

<address> <len> [data list ...] 

write some data to memory at <address> 

 

memwl 

 

<address> 

write long word to memory at <address> 

 

memrl 

 

<address> 

read long word at <address> 

 memutil 

 

 

 

 

 

usage 

 

display memory allocate and heap status 

 

 

mqueue 

<address> <len> 

display memory queues 

 

 

mcell 

mid [f|u] 

display memory cells by given ID 

  

msecs 

[a|f|u] 

display 

memory 

sections 

  

mtstart 

<n-mcell> 

start 

memory 

test 

  

mtstop 

 

stop 

memory 

test 

 

 

mtalloc 

<size> [n-mcell] 

allocate memory for testing 

 

 

mtfree 

<start-idx> [end-idx] 

free the test memory 

 model   

 

display 

server 

model 

name 

 proc   

 

 

  

display 

 

display 

all 

process 

information 

 

 

stack 

[tag] 

display process's stack by a give TAG 

 

 

pstatus 

 

display process's status by a give TAG 

 queue   

 

 

 

 

display 

[a|f|u] [start#] [end#] 

display queue by given status and range numbers

 

 

ndisp 

[qid] 

display a queue by a given number 

 

quit 

 

 

quit CI command mode 

 reboot   

[code] 

reboot system   
code = 0 cold boot,   
        = 1 immediately boot  
        = 2 bootModule debug mode 

 reslog   

 

 

  

disp 

 

display 

resources 

trace 

 

 

clear 

 

clear resources trace 

 stdio   

[second] 

change 

terminal 

timeout 

value 

 

time  

 

[hour [min [sec]]] 

display/set system time 

 timer   

 

 

  

disp 

 

display 

timer 

cell 

 

 

 

trace 

[on|off] 

set/display timer information online 

  

start 

[tmValue] 

start 

timer 

 

 

stop 

<ID> 

stop a timer 

 trcdisp  

 

monitor 

packets 

 trclog   

 

 

 

 

switch 

[on|off] 

set system trace log 

 

 

online 

[on|off] 

set on/off trace log online 

 

 

level  

[level] 

set trace level of trace log #:1-10 

 

 

type  

<bitmap> 

set trace type of trace log 

  

disp 

 

display 

trace 

log 

  

clear 

 

clear 

trace 

  

call 

 

display 

call 

event 

 

 

encapmask  

[mask] 

set/display tracelog encapsulation mask 

 trcpacket 

 

 

 

 

 

create  

<entry> <size> 

create packet trace buffer 

 

 

destroy 

 

packet trace related commands 

  

channel 

<name> 
[none|incoming|outgoing|bothway] 

<channel name>=enet0,sdsl00, fr0 
set packet trace direction for a given channel 

 

 

string 

 

enable smt trace log 

 

 

switch  

[on|off] 

turn on/off the packet trace 

  

disp 

 

display 

packet 

trace 

Содержание Prestige P660RU-T1

Страница 1: ...ZyXEL Firmware Release Note Prestige P660RU T1 Standard Version Release 3 40 ST 5 C0 Date November 17 2005 Author Sam Shi...

Страница 2: ...n V3 40 ST 5 b3 11 9 2005 1 Feature Enhancement Add reset button test Function 2 Feature Enhancement Add PPPoE pass through when PC connect to device from USB interface 3 BUG FIX SPRID 051109589 Sympt...

Страница 3: ...rding to 3 40 ST 3 C0 Modification in V3 40 ST 4 b2 08 24 2005 1 FETURE ENHANCE Modify the zero configuration web pages according to PM s requirement Modification in V3 40 ST 4 b1 08 17 2005 1 BUG FIX...

Страница 4: ...it working again Condition N A 8 FETURE CHANGED Change default romfile to Access Telecom version Modification in V3 40 ST 3 C0 06 08 2005 1 Change to FCS Modification in V3 40 ST 3 b2 06 01 2005 1 BU...

Страница 5: ...Bug Fix SPRID 050310555 Symptom in eWC can set DUT LAN ip to 0 0 0 0 in SMT menu3 2 when set it it warning 0 0 0 0 is not a valid IP address they are not match Condition N A 4 Bug Fix SPRID 050310549...

Страница 6: ...ug ADSL line right after the ADSL just entered wait for init state than ADSL will hold on this state and doesn t switch to down state the CPU loading is about 20 at the same time Modification in V3 40...

Страница 7: ...22_A_TC for supporting ADSL2 2 Modification in V3 40 ST 1 b1 12 23 2004 2 FEATURE CHANGE Symptom Change default ROM file to disable UPNP 3 FEATURE CHANGE Symptom Change the messages display format in...

Страница 8: ...l crash if USB cable was unplugged during data exchanging between MAC PC and device by USB interface 11 For CHT spec there are two point fail but almost can reach the criteria 12 Use ax 4000 test VBR...

Страница 9: ...AT choose Full Feature Step2 In Full Feature configure a NAT rule For example One to One or Many to One Step3 While complete the setting this NAT Full Feature rule can not work Then reboot DUT this ru...

Страница 10: ...0 FETURE ENHANCE Modifying the Reset System button Maintenance diagnostic General to Restart the Device Condition N A Modification in V3 40 ST 2 b1 02 21 2005 1 BUG FIXED Symptom Input the CI command...

Страница 11: ...23 2004 1 BUG FIXED Symptom in MAC 10 2 and DHCP open Can t connect to device by Telnet and FTP Modification in V3 40 ST 0 C0 12 16 2004 1 BUG FIXED Symptom Set PPPoA encapsulation and enable nail up...

Страница 12: ...BUG FIXED Symptom Use ENET ENCAP mode traffic redirect function does not work Condition N A 5 BUG FIXED Symptom Device will crash when doing PAP with INode PPPoE server Condition N A 6 BUG FIXED Symp...

Страница 13: ...ptom Do not support the ADSL opmode auto detection Condition Change modem code to 3 0 10_A_TC 6 BUG FIXED Symptom Can not sync up with Lucent ADSL2 line card Condition Change modem code to 3 0 10_A_TC...

Страница 14: ...h menu 24 2 2 and CI command sys baud Condition The console port speed is always 115200 6 BUG FIXED Symptom The operation of each LED system power DSL PPP MAC USB is not ready 7 BUG FIXED Symptom Pack...

Страница 15: ...splay date domainname display domain name edit filename edit a text file enhanced return OK if commands are supported for PWC purposes errctl level set the error control level 0 crash no save not in d...

Страница 16: ...ng buffer mail alertAddr mail address send alerts to this mail address display display mail setting logAddr mail address send logs to this mail address schedule display display mail schedule schedule...

Страница 17: ...ber quit quit CI command mode reboot code reboot system code 0 cold boot 1 immediately boot 2 bootModule debug mode reslog disp display resources trace clear clear resources trace stdio second change...

Страница 18: ...set server secure ip addr spt dump dump spt raw data root dump spt root data rn dump spt remote node data user dump spt user data slot dump spt slot data save save spt data size display spt record siz...

Страница 19: ...cast 5 mode 2 multicast 6 all packets status ch_name see LAN status init ch_name initialize LAN version see ethernet device type pkttest disp packet level set ether test packet display level event ch...

Страница 20: ...need service PPPoE LLC and Enet LLC then the service bits will be 2 32 34 decimal 22 hex you must input 22 Need to perform save after this command Remove removeNodeId vpi vci Input remote node ID and...

Страница 21: ...t set dhcp mode relay server serverIP set dicp relay server ip addr reset reset dhcp table server probecount num set dhcp probe count dnsserver IP1 IP2 IP3 set dns server ip addr winsserver winsIP1 wi...

Страница 22: ...t c Validate the reply data d Data Data pattern The maximum length of data is 255 characters f Set DF flag l Data size Datagram size in bytes with 28 bytes Header v TOS value Specify the value of TOS...

Страница 23: ...syndata on off TCP syndata piggyback trace on off turn on off trace for debugging window tcb TCP input window size samenet iface1 iface2 display the ifaces that in the same net uninet iface set the i...

Страница 24: ...no set nat server edit active flag edit svrport start port end port set nat server server port edit intport start port end port set nat server forward port edit remotehost start ip end ip set nat ser...

Страница 25: ...ZyXEL Confidential 340ST5C0 doc 25 25 disp display bridge route packet counter clear clear bridge route packet counter disp display bridge source table...