P-873HNUP-51B Support Notes
All contents copyright (c) 2011 ZyXEL Communications Corporation.
c.
Configure the Video traffic Policer.
1.
Go to
Network Settings > QoS > Policer Setup
Setup
2.
Click
Add New Policer.
3.
Check the
Enable
box.
4.
Enter the
Policer Name
box, e.g. “test”.
5.
Select the
Meter Type
as “Simple Token Bucket”.
6.
Enter the
Committed Rate
as “350”.
7.
Enter the
Committed Burst Size
as “100”.
8.
Select the
Conforming Action
as “Pass”.
9.
Select the
Non-Conforming Action
as “Drop”.
10.
Select the Class in
Available Class field
and add to
Selected Class
.