background image

 www.zyxel.com

OMC-2301

GEPON OLT Management Card

User’s Guide

Version 3.60
11/2007
Edition 1

Содержание OMC-2301

Страница 1: ...www zyxel com OMC 2301 GEPON OLT Management Card User s Guide Version 3 60 11 2007 Edition 1...

Страница 2: ......

Страница 3: ...nstallation connections maintenance hardware trouble shooting and safety warnings OLC 2301 Line Card User s Guide This user s guide introduces the GEPON OLT line card and gives detailed information ab...

Страница 4: ...in chassis The OPA 2300 is the power card It may be referred to as the power card The OFC 2300 is the fan module It may be referred to as the fan module Product labels screen names field labels and fi...

Страница 5: ...nt Conventions OMC 2301 User s Guide 5 Icons Used in Figures Figures in this User s Guide may use the following generic icons OLT 2300 Computer Server Switch Router Internet Central Office ISP ONU Spl...

Страница 6: ...device before servicing or disassembling Use ONLY an appropriate power adaptor or cord for your device Connect the power adaptor or cord to the right supply voltage for example 110V AC in North Ameri...

Страница 7: ...Safety Warnings OMC 2301 User s Guide 7...

Страница 8: ...Safety Warnings OMC 2301 User s Guide 8...

Страница 9: ...7 Advanced 77 Classifier Filter Profile 79 VLAN Profile 83 Priority Profile 93 Static MAC Forward Setup 97 Destination Filter 101 Port Authentication 105 Access Control 109 Management 121 Maintenance...

Страница 10: ...Contents Overview OMC 2301 User s Guide 10...

Страница 11: ...3 Part I Introduction 25 Chapter 1 Introducing the OMC 27 1 1 Overview 27 1 2 Applications 27 1 3 Ways to Manage the OMC 28 1 4 Good Habits for Managing the OMC 28 Chapter 2 Hardware 31 2 1 Front Pane...

Страница 12: ...esting the Internet Connection 45 Chapter 5 System Status and Port Statistics 47 5 1 Overview 47 5 2 Port Status Summary 47 5 2 1 EPON Info 48 5 2 2 EPON Details 49 5 2 3 Ethernet Port Details 55 Chap...

Страница 13: ...e Format 85 8 4 Configuring a VLAN Profile 86 8 4 1 VLAN Profile Example 89 8 4 2 VLAN Profile Example 2 90 Chapter 9 Priority Profile 93 9 1 Priority Profile Overview 93 9 2 Configuring a Priority Pr...

Страница 14: ...Requirements for Using SSH 115 13 8 Introduction to HTTPS 115 13 9 HTTPS Example 116 13 9 1 Internet Explorer Warning Messages 116 13 9 2 Netscape Navigator Warning Messages 116 13 9 3 The Main Screen...

Страница 15: ...able 138 Chapter 18 IGMP Table 141 18 1 Displaying IGMP Table 141 Part V Commands Troubleshooting and Specifications 143 Chapter 19 Introducing the Commands 145 19 1 Overview 145 19 1 1 Configuration...

Страница 16: ...verview 175 20 2 show Commands 175 20 2 1 show epon 175 20 2 2 show epon counter 176 20 2 3 show epon counter onu 177 20 2 4 show hardware monitor 177 20 2 5 show ip 178 20 2 6 show system information...

Страница 17: ...21 5 1 Resetting the Defaults Via CLI Command 195 21 5 2 Reload the Configuration File 195 21 5 3 Recovering the Firmware 196 21 6 Pop up Windows JavaScripts and Java Permissions 197 21 6 1 Internet E...

Страница 18: ...Table of Contents OMC 2301 User s Guide 18...

Страница 19: ...tails 56 Figure 16 System Info 58 Figure 17 General Setup 60 Figure 18 IP Setup 61 Figure 19 Port Setup 62 Figure 20 IGMP Proxy Network Example 64 Figure 21 EPON Setup 65 Figure 22 ONU Setup 67 Figure...

Страница 20: ...Control Service Access Control 118 Figure 57 Access Control Remote Management 119 Figure 58 Maintenance 123 Figure 59 Load Factory Default Conformation 123 Figure 60 Reboot System Confirmation 124 Fi...

Страница 21: ...1 User s Guide 21 Figure 82 Security Settings Java Scripting 201 Figure 83 Security Settings Java 202 Figure 84 Java Sun 202 Figure 85 Console Cable RJ 11 Male Connector 205 Figure 86 Console Cable DB...

Страница 22: ...List of Figures OMC 2301 User s Guide 22...

Страница 23: ...ort ONU Profile 75 Table 19 Classifier Filter Profile Setup 80 Table 20 VLAN Tag Format 85 Table 21 Single and Double Tagged 802 11Q Frame Format 85 Table 22 802 1Q Frame 86 Table 23 EPON VLAN Profile...

Страница 24: ...Command Summary User Mode 152 Table 49 Command Summary Enable Mode 155 Table 50 Command Summary Configuration Mode 159 Table 51 classifier filter profile Commands 165 Table 52 epon common Commands 166...

Страница 25: ...25 PART I Introduction Introducing the OMC 27 Hardware 31...

Страница 26: ...26...

Страница 27: ...OLT Management Card centralizes the management of all of the GEPON OLT line cards You can configure and maintain the OLT line cards through the OLT management card thus eliminating the need to connect...

Страница 28: ...ed web browser Command Line Interface Line commands are mostly used for troubleshooting by service engineers FTP for firmware upgrades and configuration backup restore SNMP The device can be monitored...

Страница 29: ...an earlier working configuration may be useful if the device becomes unstable or even crashes If you forget your password you will have to reset the OMC to its factory default settings If you backed u...

Страница 30: ...Chapter 1 Introducing the OMC OMC 2301 User s Guide 30...

Страница 31: ...following table describes the LEDs on the OMC Table 1 LEDs LED COLOR STATUS DESCRIPTION PWR Green On The OMC is receiving power Off The OMC is not receiving power SYS Green On The OMC is ready and is...

Страница 32: ...is section explains the connections to the ALM port on the management card The ALM port is a male 9 pin connector MGMT Port 10 Green On The link to a 10 Mbps Ethernet network is up Blinking The port i...

Страница 33: ...opens the circuit for pins 1 and 6 the common pin and closes the circuit for pins 2 and 6 A closed circuit on a pair of alarm input pins indicates an alarm Pins 3 and 7 are alarm input I Pins 4 and 8...

Страница 34: ...Chapter 2 Hardware OMC 2301 User s Guide 34...

Страница 35: ...35 PART II Basic Setup The Web Configurator 37 Initial Setup Example 43 System Status and Port Statistics 47 Basic Setting 57...

Страница 36: ...36...

Страница 37: ...our device Web pop up blocking is enabled by default in Windows XP SP Service Pack 2 JavaScript enabled by default Java permissions enabled by default 3 2 System Login 1 Connect your computer to the M...

Страница 38: ...or screen 3 3 The Status Screen The Status screen is the first screen that displays when you access the web configurator Figure 7 Web Configurator Home Screen Status In the navigation panel click a ma...

Страница 39: ...you to a screen where you can configure the IP address subnet mask and default gateway necessary for management Port Setup This link takes you to screens where you can configure settings for the Giga...

Страница 40: ...to use an external server to validate users Access Control This link takes you to screens where you can change the system login password and configure SNMP and remote management Management Maintenanc...

Страница 41: ...replaces the current configuration file with the factory default configuration file This means that you will lose all previous configurations and the speed of the console port will be reset to the def...

Страница 42: ...finish a management session for security reasons Figure 10 Web Configurator Logout Screen 3 7 Help The web configurator s online help has descriptions of individual screens and some supplementary inf...

Страница 43: ...ccess the Internet through the ONU For the test network you create a service profile on the OMC with the pre defined 100Mbps bandwidth limit and apply it to the ONU Figure 11 Initial Setup Network Exa...

Страница 44: ...254 with a subnet mask of 255 255 255 0 2 Open a web browser and enter the management IP address of the OMC The default is 192 168 0 1 3 Enter the login username admin is the default and password 1234...

Страница 45: ...1 You should see that the upstream and downstream bandwidths for the ONU are set to 100 Mbps 4 4 Testing the Internet Connection In this section you test Internet access through the ONU as a subscribe...

Страница 46: ...Chapter 4 Initial Setup Example OMC 2301 User s Guide 46...

Страница 47: ...h links to each port showing statistical details 5 2 Port Status Summary To view the port statistics click Status in any web configurator screen The Status screen displays as shown next Figure 12 Stat...

Страница 48: ...his port without errors Up Time This field shows the total amount of time in hours minutes and seconds the port has been up Uplink Port This identifies the Gigabit Ethernet port Click a port number to...

Страница 49: ...the ONU is waiting for the firmware upgrade Upgrading when the ONU is upgrading its firmware Upgrade Fail ONU firmware upgrade has failed In this case reset the ONU See Chapter 14 on page 123 to rese...

Страница 50: ...Chapter 5 System Status and Port Statistics OMC 2301 User s Guide 50 Figure 14 Status EPON Info EPON Details...

Страница 51: ...Chapter 5 System Status and Port Statistics OMC 2301 User s Guide 51...

Страница 52: ...ical link Minimum Upstream Bandwidth This field displays the minimum upstream bandwidth in Mbps Maximum Upstream Bandwidth This field displays the maximum upstream bandwidth in Mbps Maximum Downstream...

Страница 53: ...ys the number of errored octets received by the UNI port ONU PON Octets Tx OK This field displays the number of octets transmitted successfully to the ONU Rx OK This field displays the number of octet...

Страница 54: ...transmitted Grant Frames Received OK This field displays the number of grant frames received OLT Gate Frames Transmitted OK This field displays the number of gate frames transmitted from the OLT ONU G...

Страница 55: ...r an Errored Frames alarm has occurred Errored Frame Period This field indicates whether an Errored Frames Period alarm has occurred Errored Frames Second Summary This field indicates whether an Error...

Страница 56: ...t and broadcast transmitted Pause This field shows the number of 802 3x Pause packets transmitted LLID1 This field shows the number of packets transmitted to the ONU Rx Packet The following fields dis...

Страница 57: ...system time manually or get the current time and date from an external server when you turn on your OMC The real time is then displayed in the logs The IP Setup screen allows you to configure the mana...

Страница 58: ...and reporting if the temperature rises above the threshold You may choose the temperature unit Centigrade or Fahrenheit in this field Temperature CPU ADM6996IX 1 and ADM6996IX 2 refer to the location...

Страница 59: ...n is functioning above the minimum speed Error indicates that this fan is functioning below the minimum speed If Error displays it is recommended that the fan s on the OMC be replaced by a qualified t...

Страница 60: ...en see Figure 67 on page 131 Use Time Server when Bootup Enter the time service protocol that a timeserver sends when you turn on the OMC Not all time servers support all protocols so you may have to...

Страница 61: ...nd second format The new time then appears in the Current Time field after you click Apply Current Date This field displays the date you open this menu New Date yyyy mm dd Enter the new date in year m...

Страница 62: ...14 Port Setup LABEL DESCRIPTION Uplink Port This is the uplink port index number The digit s before 0 in a port number corresponds to the card slot on the OLT and the last digit denotes the port type...

Страница 63: ...the port that is closer to the source or the root of the multicast tree and is able to receive multicast traffic There should only be one upstream interface also known as the query port on the system...

Страница 64: ...atic multicast traffic to an uplink port Only the uplink port can forward multicast traffic to the PON port 6 7 DBA Dynamic Bandwidth Allocation In an EPON network to prevent network congestion dynami...

Страница 65: ...BA algorithm the OLT assigns bandwidth based on report messages from ONUs link priority and delay tolerance In addition the OLT guarantees a minimum upstream bandwidth and provides the best effort max...

Страница 66: ...rity 7 Typically used for network control traffic such as router configuration messages Priority 6 Typically used for voice traffic that is especially sensitive to jitter jitter is the variations in d...

Страница 67: ...ownstream packets with a matching multicast MAC address in the range shown Select Discard to drop downstream packets with a matching multicast MAC address in the range shown Apply Click Apply to save...

Страница 68: ...information on 4 port ONU profile setup Add Click Add to save the settings Cancel Click Cancel to reset the fields to your previous configuration Clear Click Clear to reset the fields to the default s...

Страница 69: ...ings you can apply it to the ONU in the ONU Setup screens refer to Section 6 9 on page 67 Your OMC comes with a Default profile contains the settings that work in most network environment When you cre...

Страница 70: ...following table describes the labels in this screen Table 17 EPON Profile LABEL DESCRIPTION Active Select this option to activate this profile Clear this check box to disable the profile Name Enter a...

Страница 71: ...m upstream bandwidth for packets in queue 0 The number you entered is multiplied by 100 Maximum Queue 1 Bandwidth Specify the maximum upstream bandwidth for packets in queue 1 The number you entered i...

Страница 72: ...aximum Queue 3 Bandwidth Specify the maximum downstream bandwidth for packets in queue 3 The number you entered is multiplied by 100 Downstream Priority Queue Size 1 Port ONU only Active Select Active...

Страница 73: ...to limit the number of dynamic source MAC addresses that may be learned on the ONU For example if you set this field to 8 then only the devices with these eight learned MAC addresses may access throug...

Страница 74: ...ata packet leaves for both ports Port based VLANs are specific only to the device on which they were created 6 12 4 Port ONU Profile Use the 4 Port ONU Profile screen to create or edit a profile that...

Страница 75: ...box to disable the profile Name Enter a descriptive name up to 20 alphanumerical characters to identify this profile Port based VLAN Select whether to activate port based VLAN on the ONU ONU PHY This...

Страница 76: ...the size in byte for queue 0 The number you entered is multiplied by 128 Queue 1 Size Specify the size in byte for queue 1 The number you entered is multiplied by 128 Queue 2 Size Specify the size in...

Страница 77: ...77 PART III Advanced Classifier Filter Profile 79 VLAN Profile 83 Priority Profile 93 Static MAC Forward Setup 97 Destination Filter 101 Port Authentication 105 Access Control 109...

Страница 78: ...78...

Страница 79: ...tion IP address or the TCP UDP source port number 7 2 Classifier Filter Profile Setup Use the Classifier Filter Profile screen to configure actions on the grouped traffic flow Your OMC comes with two...

Страница 80: ...d to drop outgoing VLAN tagged packets Select Pass to forward outgoing VLAN tagged packets Downstream Default VLAN Filter Specify how the ONU is to treat incoming tagged untagged packets from the OMC...

Страница 81: ...TCP Port or Src UDP Port in the Filter Rules field enter a TCP service port number 1 65535 If you select Src IP Address in the Filter Rules field enter a source IP address in dotted decimal notation F...

Страница 82: ...Chapter 7 Classifier Filter Profile OMC 2301 User s Guide 82...

Страница 83: ...s to an untagged port The remaining twelve bits define the VLAN ID giving a possible maximum number of 4 096 VLANs Note that user priority and VLAN ID are independent of each other A frame with VID VL...

Страница 84: ...k Use VLAN stacking to add an outer VLAN tag to the inner IEEE 802 1Q tagged frames that enter the network By tagging the tagged frames double tagged frames the service provider can manage up to 4 094...

Страница 85: ...affic based on the class of service CoS the customer has paid for On the OMC configure priority level on inner IEEE 802 1Q in the VLAN Profile screen 0 is the lowest priority level and 7 is the highes...

Страница 86: ...Add or remove an outer VLAN tag Set priority No action is done on the OLT which forwards the packets to the destination through the uplink Gigabit Ethernet ports Click Advanced Applications VLAN Profi...

Страница 87: ...e up to 20 alpha numerical characters with spaces allowed to identify this VLAN profile Upstream Default VLAN Rule Configure the default settings for outgoing traffic from the ONU to the OLT that does...

Страница 88: ...eletes the outer VLAN tag that matches this VLAN ID from incoming packets If you select Exchange in the Action field this replaces the packet s VLAN ID Priority Src Select Original if you don t want t...

Страница 89: ...the system sets the VLAN type to 8100 regardless of your setting here For tagged frames the system sets the VLAN type 8100 88A8 or 9100 that you specify Priority Src Select Original if you don t want...

Страница 90: ...screen apply the configured VLAN profile to the ONU 8 4 2 VLAN Profile Example 2 In the following example you want to set the ONU to check VLAN tagged packets from the OLT If a packet has a VLAN ID of...

Страница 91: ...om the incoming packets Figure 32 VLAN Profile Example 2 In the Classifier Filter Profile screen set the Downstream Default VLAN Filter to discard all untagged packets on the ONU Figure 33 VLAN Profil...

Страница 92: ...Chapter 8 VLAN Profile OMC 2301 User s Guide 92...

Страница 93: ...alue is then mapped to the physical queue you specify in the EPON Common Setup screen The The OMC determines the COS value of a packet using one of the following methods Using the IEEE 802 1p priority...

Страница 94: ...ame Enter a descriptive name up to 20 alphanumerical characters to identify this profile TOS COS Conversion TOS COS mapping on the ONU ensures that quality of service is maintained as packets go throu...

Страница 95: ...ows flexible prioritization Enter a number between 0 and 7 The bigger the number the higher the priority IP Address This field is applicable if you select either Source IP Address or Destination IP Ad...

Страница 96: ...roup The AppleTalk packets are sent out through queue 3 Thus AppleTalk packets in a VLAN group have the highest priority and get sent first The following figure shows the example configuration Figure...

Страница 97: ...you are setting static MAC addresses for a port This may reduce the need for broadcasting 10 2 Static MAC Forwarding Status You can view the number of static MAC forwarding rules you configure per Eth...

Страница 98: ...This read only field displays the port index number Active Select this check box to activate your rule You may temporarily deactivate a rule without deleting it by clearing this check box Name Enter a...

Страница 99: ...d displays the MAC address of the packets that will be forwarded Delete Select the entry ies that you want to remove in the Delete column and then click the Delete button Cancel Click Cancel to clear...

Страница 100: ...Chapter 10 Static MAC Forward Setup OMC 2301 User s Guide 100...

Страница 101: ...to see how many destination filters you have configured on each port Click Advanced Application Destination Filter Status Figure 38 Destination Filter Status The following table describes the labels i...

Страница 102: ...estination MAC address of the packets to filter Action Select Discard to drop packets to the MAC address specified in the MAC Address field The ONU can still receive packets originating from the MAC a...

Страница 103: ...destination MAC address of 00 00 00 00 a0 5f to the ONU named CA1101 Figure 40 Destination Filter Example Delete Select the rule s that you want to remove in the Delete column and then click the Delet...

Страница 104: ...Chapter 11 Destination Filter OMC 2301 User s Guide 104...

Страница 105: ...sers by means of an external server instead of or in addition to an internal device user database that is limited to the memory capacity of the device In essence RADIUS authentication allows you to va...

Страница 106: ...able port authentication activate IEEE802 1x security both on the system and the port s on the OLC configure the RADIUS server settings Click Advanced Application Port Authentication in the navigation...

Страница 107: ...ansmission period This is the time the OMC waits for the response from a client before sending the request to the authentication server Supplicant timeout This is the time the OMC waits for a response...

Страница 108: ...hared Secret Specify a password up to 30 alphanumeric characters as the key to be shared between the external RADIUS server and the OMC This key is not sent over the network This key must be the same...

Страница 109: ...ng error message displays If you disable multiple login while another administrator is accessing the OMC via telnet the OMC will immediately log out the administrator and disconnect the telnet session...

Страница 110: ...ged network consists of two main components agents and a manager An agent is a management software module that resides in a managed device this OMC An agent translates the local management information...

Страница 111: ...nds COMMAND DESCRIPTION Get Allows the manager to retrieve an object variable from the agent GetNext Allows the manager to retrieve the next object variable from a table or list within an agent In SNM...

Страница 112: ...ng other than admin is someone who can view but not configure OMC settings It is highly recommended that you change the default administrator password 1234 Click Access Control from the navigation pan...

Страница 113: ...the admin user name You cannot change the default administrator user name Only the administrator has read write access Old Password Type the existing system password up to 30 characters 1234 is the d...

Страница 114: ...s the result back to the server The client automatically saves any new server public keys In subsequent connections the server public key is checked against the saved version on the client computer 2...

Страница 115: ...thentication one party can identify the other party and data integrity you know if data has been changed It relies upon certificates public keys and private keys HTTPS on the OMC is used so that you m...

Страница 116: ...ificate if you want to verify that the certificate is from the OMC You see the following Security Alert screen in Internet Explorer Click Yes to proceed to the web configurator login screen if you cli...

Страница 117: ...icate 1 Netscape Figure 54 Security Certificate 2 Netscape 13 9 3 The Main Screen After you accept the certificate and enter the login username and password the OMC main screen appears The lock displa...

Страница 118: ...d configure trusted computer s for each service in the Remote Management screen discussed later Click Access Control to go back to the main Access Control screen Figure 56 Access Control Service Acces...

Страница 119: ...t idle before the session times out After it times out you have to log in with your password again Very long idle timeouts may have security risks Apply Click Apply to save your changes back to the OM...

Страница 120: ...Control OMC 2301 User s Guide 120 Apply Click Apply to save your changes back to the OMC Cancel Click Cancel to begin configuring this screen afresh Table 39 Access Control Remote Management continued...

Страница 121: ...121 PART IV Management Maintenance 123 Diagnostic 131 Syslog 133 MAC Table 137 IGMP Table 141...

Страница 122: ...122...

Страница 123: ...m remote ONU firmware upgrade and reset the line card s the ONU s or the fiber connections Click Management Maintenance in the navigation panel to open the following screen Figure 58 Maintenance 14 2...

Страница 124: ...Reboot System to display the next screen Figure 60 Reboot System Confirmation 2 Click OK This takes up to two minutes This does not affect the OMC s configuration 14 4 Remote ONU Firmware Upgrade You...

Страница 125: ...on a port the OMC updates firmware to one ONU at a time starting from the one with the smallest index number 14 5 Line Card Reset Use the Line Card Reset screen to reset the selected line card s Rese...

Страница 126: ...elect the LLID s you want to reset in the list box You can select multiple entries by holding down the SHIFT or CTRL key 4 Click Reset to reset the selected LLID s Resetting the ONUs does NOT restart...

Страница 127: ...computer to the OMC using the Restore Configuration screen Figure 65 Restore Configuration Type the path and file name of the configuration file you wish to restore in the File Path text box or click...

Страница 128: ...settings in the screens such as password OMC setup IP Setup etc Once you have customized the OMC s settings they can be saved back to your computer under a filename of your choosing ZyNOS ZyXEL Netwo...

Страница 129: ...tion file on your computer config cfg to the OMC and renames it to config Likewise get config config cfg transfers the configuration file on the OMC to your computer and renames it to config cfg See T...

Страница 130: ...ions FTP will not work when FTP service is disabled in the Access Control screen The IP address es in the Secured Client Set in the Remote Management screen does not match the client IP address If it...

Страница 131: ...display system logs ping IP addresses or test line connections Figure 67 Diagnostic The following table describes the labels in this screen Table 41 Diagnostic LABEL DESCRIPTION System Log Click Prev...

Страница 132: ...e up to 1000 logs on the OMC Once the number is reached the OMC wraps around and deletes the old logs To save logs on an external syslog server configure the Syslog Server Setup screen refer to Sectio...

Страница 133: ...program for details The following table describes the syslog severity levels 16 2 Syslog Setup On the OMC make sure the external syslog server is connected to the MGMT port Click Management Syslog in...

Страница 134: ...DESCRIPTION Syslog Select Active to turn on syslog system logging and then configure the syslog setting Logging Type This column displays the names of the log categories that the device can generate...

Страница 135: ...Add Click Add to save your changes back to the device The entry displays in the table below Cancel Click Cancel to begin configuring this screen afresh Clear Click Clear to return the fields to the f...

Страница 136: ...Chapter 16 Syslog OMC 2301 User s Guide 136...

Страница 137: ...is source MAC address came 2 If the MAC table is full and the OMC receives a frame with an unknown MAC address the frame is discarded 3 The OMC checks to see if the frame s destination MAC address mat...

Страница 138: ...frame No No Yes Yes Discard Table 45 MAC Table LABEL DESCRIPTION Sort by Select an option to display and arrange the MAC address information based on the MAC address or LLID Port Select Select the nu...

Страница 139: ...9 LLID This is the link ID to which the MAC address is associated Type This shows whether the MAC address is dynamic learned by the OMC or static manually entered in the Static MAC Forwarding screen T...

Страница 140: ...Chapter 17 MAC Table OMC 2301 User s Guide 140...

Страница 141: ...o Section 6 6 on page 63 Figure 72 IGMP Table The following table describes the labels in this screen Table 46 IGMP Table LABEL DESCRIPTION Port Select Select the number of a port from which you want...

Страница 142: ...Chapter 18 IGMP Table OMC 2301 User s Guide 142...

Страница 143: ...143 PART V Commands Troubleshooting and Specifications Introducing the Commands 145 Command Examples 175 Troubleshooting 191 Product Specifications 203...

Страница 144: ...144...

Страница 145: ...configurable by the web configurator 19 1 1 Configuration File When you configure the OMC using either the CLI or web configurator the settings are saved as a series of commands in a configuration fi...

Страница 146: ...owed To disable this feature use the configure no user session command 19 2 2 The Console Port Connect to the OMC s console port using a terminal emulation software configured to the following setting...

Страница 147: ...e eavesdropping on you right now man in the middle attack It is also possible that the host key has just been changed Please contact your system administrator Add correct host key to C Documents and S...

Страница 148: ...Command refers to a command used The symbol means or The entry cr in the command lines refers to carriage return Press ENTER or carriage return after a command to execute the command Use the up y or d...

Страница 149: ...me for the profile For example enter classifier filter profile Web to create a new Web profile and enter sub configuration mode epon common To enter the classifier filter profile mode enter epon commo...

Страница 150: ...information show mac address port number cr show mac address port number llid show mac address port number static show radius server show snmp server show service control show remote management cr sh...

Страница 151: ...y to scroll through the previously used commands and press ENTER Use the history command to display the list of commands sysname enable Turn on privileged commands exit Exit from the EXEC help Descrip...

Страница 152: ...e commands available in the OMC with a brief description of each command Commands listed in the tables are in the same order as they are displayed in the CLI See the related section in the User s Guid...

Страница 153: ...k onu port number llid Displays ONU connection counters epon da filter port number Displays destination address DA filter s configured on the specified port epon daily counter port number Displays the...

Страница 154: ...ority profile summary table queue mapping Displays the queue mappings radius server Displays the RADIUS server settings remote management Displays remote management settings index Displays specified r...

Страница 155: ...contains three or four digits such as 101 or 1402 The digit s before 0 in a port number corresponds to the card slot on the OLT and the last digit denotes the port type 1 for PON port and 2 for uplink...

Страница 156: ...tains three or four digits such as 101 or 1402 The digit s before 0 in a port number corresponds to the card slot on the OLT and the last digit denotes the port type 1 for PON port and 2 for uplink po...

Страница 157: ...d Displays the daily link statistics on the link ID s epon onu4 profile Displays EPON 4 port ONU profile summary table profile name Displays detailed settings of the specified EPON 4 port ONU profile...

Страница 158: ...client information index Displays the specified secured client information running config Displays current operating configuration service control Displays service control settings snmp server Display...

Страница 159: ...ion file the OMC is currently using index Saves the configuration to the specified configuration file on the switch Table 49 Command Summary Enable Mode continued COMMAND DESCRIPTION Table 50 Command...

Страница 160: ...sa Re generates a certificate timeout 0 65535 Sets the HTTPS timeout period ip address ip mask Sets the management IP address and subnet mask default gateway ip Sets the default gateway s IP address n...

Страница 161: ...l to the OMC https Disables secure web browser access to the OMC icmp Disables ICMP access to the OMC such as pinging and tracerouting snmp Disables SNMP management ssh Disables SSH Secure Shell serve...

Страница 162: ...on the OMC port list Enables 802 1x authentication on the specified port s max reauth number 1 10 Sets the maximum number of times the OMC is to prompt for the subscriber username and password to sta...

Страница 163: ...et number 1 255 Allows HTTP access on the specified service port and defines the timeout period https socket number Allows HTTPS access on the specified service port icmp Allows ICMP access for servic...

Страница 164: ...sync daytime time ntp Sets the time server protocol server ip Sets the IP address of your time server uplink uplink port list Enters Uplink Configuration mode active Activates the specified port s end...

Страница 165: ...lassifier rule index 1 8 active Enables this classifier rule 1 8 no active Disable this classifier rule 1 8 value ethertype 0x0000 0xFF0F ipv4 1 255 port 0 65535 ip Sets the packet type to classify cl...

Страница 166: ...les this classifier rule no active Disable this classifier rule value 1 4094 Sets the VLAN ID of the traffic to classify Table 51 classifier filter profile Commands continued COMMAND DESCRIPTION Table...

Страница 167: ...IEEE 802 1p priority queue mapping for the upstream traffic Table 52 epon common Commands continued COMMAND DESCRIPTION Table 53 epon onu4 profile Commands COMMAND DESCRIPTION epon onu4 profile name S...

Страница 168: ...on the ONU flow control Enables flow control for the connection to the specified port on the ONU power down Disables the connection to the specified port on the ONU speed 10 100 Sets the connection sp...

Страница 169: ...ets the queue size dn queue policing Enables downstream queue policing queue 0 3 max bw 1 10000 Sets the maximum bandwidth for the queue encryption mode both downstream Sets data encryption on the dow...

Страница 170: ...am queue policing queue 0 3 max bw 1 10000 Sets the maximum upstream for the queue Table 54 epon profile Commands continued COMMAND DESCRIPTION Table 55 onu Commands COMMAND DESCRIPTION onu name port...

Страница 171: ...e Sets a classifier type direction downstream upstream Sets the traffic direction to prioritize no active Disables the layer2 priority rule s in the profile queue 0 3 Specifies the outgoing queue for...

Страница 172: ...ocol number for the rule downstream def rule action delete exchange vid 1 4094 priority src original priority profile Sets the default rule settings for the downstream traffic action none Clears the d...

Страница 173: ...le action add exchange vlan type 8100 9100 88A8 vid 1 4094 priority src original priority profile Sets the default rule settings for upstream traffic action none Clears the default rule settings for u...

Страница 174: ...Chapter 19 Introducing the Commands OMC 2301 User s Guide 174...

Страница 175: ...epon Syntax show epon show epon port number llid Use this command to display the status of all PON ports You can also use this command to view detailed status on each LLID The following example shows...

Страница 176: ...00 0a The Number of LLID 1 Up Time 2 47 20 ONU Name LLID MAC Address Default 1 00 00 00 00 00 09 sysname sysname show epon 801 1 Active LLID 1 ONU Name Default EAP State Disconnected Status Up Normal...

Страница 177: ...he device temperature and voltage readings and fan speeds You can choose to display the temperature in Celsius C or Fahrenheit F sysname show epon counter onu 801 1 Report Frames Tx OK 0 Rx OK 0 Gate...

Страница 178: ...rmal ADM6996IX 1 46 0 49 5 45 0 93 0 Normal ADM6996IX 2 46 5 49 5 46 0 87 0 Normal FAN Speed RPM Current Max Min Threshold Status FAN1 0 0 0 6000 Error FAN2 0 0 0 6000 Error FAN3 0 0 0 6000 Error FAN4...

Страница 179: ...k of the OMC Set the IP address of the default gateway Exit configuration mode Saves current configuration to the configuration file the OMC is currently using 20 4 ping Syntax ping ip host name size...

Страница 180: ...n configuration mode ip host name The IP address or host name of an Ethernet device size 0 1472 Specifies the packet size to send sysname ping 172 23 37 120 Resolving 172 23 37 120 172 23 37 120 sent...

Страница 181: ...a min up bw 0 16000 max up bw 0 16000 epon profile name dba priority class 0 7 epon profile name dn policing epon profile name dn policing max burst 0 8191 epon profile name dn policing max dn bw 0 16...

Страница 182: ...esses may access port 2 at any one time A ninth device would have to wait until one of the eight learned MAC addresses aged out dn policing Applies the EPON profile settings to the downstream traffic...

Страница 183: ...can set the OMC to use a different configuration file There are two ways in which you can set the OMC to use a different configuration file restart the OMC cold reboot and restart the system warm reb...

Страница 184: ...xample uploads the configuration file test cfg from the TFTP server 172 16 19 96 to the OMC 20 8 4 Resetting to the Factory Default Follow the steps below to reset the OMC back to the factory defaults...

Страница 185: ...osts host ip 1024 ssh rsa ssh dsa where An example is shown next Disable the secure shell RSA1 encryption key Remove the remote host with IP address 172 165 1 8 from the list of known hosts Disables p...

Страница 186: ...configure a priority profile sysname config no ssh key rsa1 sysname config no ssh known hosts 172 165 1 8 sysname config no ssh known hosts 172 165 1 9 ssh rsa name Creates a new priority profile or...

Страница 187: ...profile profile name onu name port list vlan profile profile name where sysname config priority profile normal sysname config priority profile active sysname config priority profile l2 rule 1 classifi...

Страница 188: ...7 type ethertype ipv4 vlan vlan profile name downstream rule 1 7 action delete exchange none vlan profile name downstream rule 1 7 new vid 1 4094 vlan profile name downstream rule 1 7 priority src or...

Страница 189: ...the VLAN ID field Select none to forward packets without any changes new vid 1 4094 Enter a VLAN ID from 1 to 4094 of the packet For the exchange action this replaces the packet s VLAN ID priority sr...

Страница 190: ...Chapter 20 Command Examples OMC 2301 User s Guide 190...

Страница 191: ...ons and safety warnings on installing the management card and power connections for the OLT 2300 V The ALM 1 LED is on An alarm has been detected on the OMC the fan module or the input alarm terminals...

Страница 192: ...he correct IP address The default out of band IP address is 192 168 0 1 If you changed the IP address use the new IP address If you changed the IP address and have forgotten it see the troubleshooting...

Страница 193: ...the configuration file I cannot use FTP to upload new firmware See the troubleshooting suggestions for I cannot see or access the Login screen in the web configurator Ignore the suggestions about you...

Страница 194: ...inal emulation software with the correct settings default VT100 terminal emulation 115200 bps No parity 8 data bits 1 stop bit and no flow control 21 3 Management Lockout You could lock yourself and a...

Страница 195: ...of admin and password of 1234 21 5 2 Reload the Configuration File If you forget your password and the management IP address you can reload the configuration file via the console port Uploading the f...

Страница 196: ...er 2 Connect your computer to the console port and use terminal emulation software configured to the following parameters 3 Turn off the OLT 2300 and turn it back on to restart it and begin a session...

Страница 197: ...1 6 Pop up Windows JavaScripts and Java Permissions In order to use the web configurator you need to allow Web browser pop up windows from your device JavaScripts enabled by default Java permissions e...

Страница 198: ...ps check box in the Pop up Blocker section of the screen This disables any web pop up blockers you may have enabled Figure 78 Internet Options 3 Click Apply to save this setting 21 6 1 2 Enable pop up...

Страница 199: ...re 79 Internet Options 3 Type the IP address of your device the web page that you do not want to have blocked with the prefix http For example http 192 168 1 1 4 Click Add to move the IP address to th...

Страница 200: ...rly in Internet Explorer check that JavaScripts are allowed 1 In Internet Explorer click Tools Internet Options and then the Security tab Figure 81 Internet Options 2 Click the Custom Level button 3 S...

Страница 201: ...Java Scripting 21 6 3 Java Permissions 1 From Internet Explorer click Tools Internet Options and then the Security tab 2 Click the Custom Level button 3 Scroll down to Microsoft VM 4 Under Java permi...

Страница 202: ...02 Figure 83 Security Settings Java 21 6 3 1 JAVA Sun 1 From Internet Explorer click Tools Internet Options and then the Advanced tab 2 make sure that Use Java 2 for applet under Java Sun is selected...

Страница 203: ...sword 1234 Default Console Port Settings VT100 terminal emulation 115200 bps No parity 8 data bits 1 stop bit and no flow control Table 59 OMC 2301 Specifications Interface Ethernet One 10 100 Mbps po...

Страница 204: ...IGMP snooping Per ONU LLID MAC address learning Limited maximum number of MAC addresses Up to 16 static MAC address VLAN Port based VLAN IEEE 802 1q VLAN mapping Up to 8 VLAN rules per ONU Three VLAN...

Страница 205: ...ooping IGMP V1 and v2 Broadcast methodology IGMP membership reports Tracking MAC address with IGMP 256 multicast groups Max ACL Filtering L2 frame filtering such as based on source MAC address port et...

Страница 206: ...oduct Specifications OMC 2301 User s Guide 206 Figure 86 Console Cable DB 9 Female Connector Table 61 Console Cable Connector Pin Assignments RJ 11 MALE DB 9 FEMALE Pin 2 TXD Pin 2 Pin 3 RXD Pin 3 Pin...

Страница 207: ...207 PART VI Appendix and Index The appendices provide general information Some details may not apply to your OMC Legal Information 209 Customer Support 213 Index 219...

Страница 208: ...208...

Страница 209: ...ftware described herein Neither does it convey any license under its patent rights nor the patent rights of others ZyXEL further reserves the right to make changes in any products described herein wit...

Страница 210: ...expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num riqu...

Страница 211: ...irect or consequential damages of any kind to the purchaser To obtain the services of this warranty contact ZyXEL s Service Center for your Return Material Authorization number RMA Products must be re...

Страница 212: ...Appendix A Legal Information OMC 2301 User s Guide 212...

Страница 213: ...ail support zyxel com tw Sales E mail sales zyxel com tw Telephone 886 3 578 3942 Fax 886 3 578 2439 Web www zyxel com www europe zyxel com FTP ftp zyxel com ftp europe zyxel com Regular Mail ZyXEL Co...

Страница 214: ...8 Web www zyxel fi Regular Mail ZyXEL Communications Oy Malminkaari 10 00700 Helsinki Finland France E mail info zyxel fr Telephone 33 4 72 52 97 97 Fax 33 4 72 52 19 20 Web www zyxel fr Regular Mail...

Страница 215: ...gawa ku Tokyo 141 0022 Japan Kazakhstan Support http zyxel kz support Sales E mail sales zyxel kz Telephone 7 3272 590 698 Fax 7 3272 590 689 Web www zyxel kz Regular Mail ZyXEL Kazakhstan 43 Dostyk A...

Страница 216: ...rzei 1A 03 715 Warszawa Poland Russia Support http zyxel ru support Sales E mail sales zyxel ru Telephone 7 095 542 89 29 Fax 7 095 542 89 25 Web www zyxel ru Regular Mail ZyXEL Russia Ostrovityanova...

Страница 217: ...ZyXEL Thailand Co Ltd 1 1 Moo 2 Ratchaphruk Road Bangrak Noi Muang Nonthaburi 11000 Thailand Ukraine Support E mail support ua zyxel com Sales E mail sales ua zyxel com Telephone 380 44 247 69 78 Fax...

Страница 218: ...Appendix B Customer Support OMC 2301 User s Guide 218...

Страница 219: ...6 change password 148 login password 148 management interface 146 Click 141 Command Summary 152 Syntax conventions 148 Command Line Interface Accessing 145 Introduction 145 common Ethernet type 95 com...

Страница 220: ...features 204 fiber port setup 65 fiber port status 48 Fiber To The Building FTTB 28 Fiber To The Home See also FTTH 27 File Transfer Protocol See also FTP 128 filename convention 128 filter 79 filter...

Страница 221: ...ss 61 management interface CLI 146 management IP address 37 management IP setting 61 managing the device good habits 28 using FTP See FTP using Telnet See command interface using the command interface...

Страница 222: ...123 reset to factory default settings 123 resetting ONU 126 resetting PON port 125 resetting the defaults 195 restart device 124 restore configuration 127 restore configuration file 41 RFC 2138 RFC 2...

Страница 223: ...ping 93 trademarks 209 trap 111 destination 112 U Universal Time Coordinated See also UTC 61 update firmware 126 USER Telco 50 Connectors 205 UTC 61 V VID 83 view system log 131 Virtual Local Area Net...

Страница 224: ...Index OMC 2301 User s Guide 224...

Отзывы: