Server
Password
Enter the password for the server’s identification code. This shared
public key is used by the MAX208M2W Series during the communication
handshake process to identify the server.
Server Nonce
The MAX208M2W Series and the OMA-DM server use nonces to
authenticate each other if you select MD5 as the authentication
algorithm in the Server Auth Type field. Nonce is an abbreviation of
'number used once'. It is normally a random or pseudo-random number
applied in an authentication protocol to protect existing
communications from being reused in ‘replay attacks’.
Type up to 20 digits for the OMA-DM server nonce.
Client Auth
Type
Select the encryption algorithm scheme used by the OMA-DM server to
communicate with client devices. If the scheme selected here does not
match the actual scheme used by the server, then server will challenge
the MAX208M2W Series to automatically update its settings.
• None - No authentication.
• Basic - Server ID and Password are encoded using a Basic Access
Authentication Code.
• Digest (MD5) - Server ID and Password are encoded using a Digest
Access Authentication Code.
• HMAC - Server ID and Password are encoded using a keyed Hash
Message Authentication Code.
Note: Make sure that the scheme selected here matches the the
Server Auth Type
.
Client ID
Enter the client name for the MAX208M2W Series.
Client Password
Enter the password for the MAX208M2W Series’s client name.
Client Nonce
The MAX208M2W Series and the OMA-DM server use nonces to
authenticate each other if you select MD5 as the authentication
algorithm in the Client Auth Type field.
Type up to 20 digits for the OMA-DM client nonce.
Perodical Client-
Initiated Enable
Select this to allow the MAX208M2W Series to periodically connect to
the OMA-DM server and check for configuration updates.
If you do not enable this feature then the MAX208M2W Series can only
be updated automatically when the OM-DM server initiates contact with
it and if you selected the checkbox on this screen.
Periodical
Client-Initiated
Interval
Enter the time interval (in seconds) at which the MAX208M2W Series
connects to the OMA-DM server.
Table 68
OMA-DM (continued)
LABEL
DESCRIPTION
Содержание MAX218M2W
Страница 2: ......
Страница 10: ...Contents Overview MAX208M2W Series User s Guide 10...
Страница 16: ...Table of Contents MAX208M2W Series User s Guide 16 Index 297...
Страница 17: ...17 PART I User s Guide...
Страница 18: ...18...
Страница 24: ...Chapter 1 Getting Started MAX208M2W Series User s Guide 24...
Страница 42: ...Chapter 3 Setup Wizard MAX208M2W Series User s Guide 40...
Страница 62: ...Chapter 4 Tutorials MAX208M2W Series User s Guide 60...
Страница 63: ...61 PART II Technical Reference...
Страница 64: ...62...
Страница 90: ...Chapter 6 WiMAX MAX208M2W Series User s Guide 88...
Страница 134: ...Chapter 8 Security MAX208M2W Series User s Guide 132...
Страница 158: ...Chapter 10 The VoIP Account Screens MAX208M2W Series User s Guide 156...
Страница 206: ...Chapter 14 Product Specifications MAX208M2W Series User s Guide 202...
Страница 238: ...Appendix B Setting Up Your Computer s IP Address MAX208M2W Series User s Guide 234...
Страница 248: ...Appendix C Pop up Windows JavaScript and Java Permissions MAX208M2W Series User s Guide 244...
Страница 292: ...Appendix E Importing Certificates MAX208M2W Series User s Guide 288...
Страница 306: ...Index MAX208M2W Series User s Guide 302...