background image

 

1.  Introduction to the G-6000 

The ZyXEL G-6000 is a Wireless Bridge for Inter-building Point to Point Ethernet connection. By supporting 

AES/TKIP

, G-6000 is particularly suited for sensitive data transmission. System privacy is also inherent 

through the MAC & 802.1x based mutual authentication functionality. Outdoor-mounted design with 
weatherproof enclosure and connecting with low loss cable to antenna achieves outstanding performance in 
the longer communication distance. The power over Ethernet (POE) technology supplies the power and 
Ethernet connectivity via a single Ethernet cable and allows users to install system quickly. G-6000 meets 
FCC 15.203 regulations. The G-6000 is strictly intended for sale to the professional market as it requires 
sophisticated installation methods and is an integral part of a larger infrastructure that will be sold to ZyXEL 
licensed operators as a package. The G-6000 uses a standard N-type connector however it requires installation 
done only by a licensed professional due to the complexity of the technology and product. Installation 
requires special training by ZyXEL to align the antennas.   

2. Product installation requirements 

1. The G-6000 can only be installed by a licensed installer; training and access to technical requirements will 
be provided through the user guide and through training done by the business partnership agreements with 
respective customers. 
2. The installation will be done in a controlled and licensed environment; and filing of the appropriate 
documentation as required by local law. 
3. Installation requires special training (special programming, access to keypad, field strength measurements 
made) by ZyXEL of the installation and maintenance teams of the ZyXEL licensed service providers and 
operators. 
4. ZyXEL licensed service providers will be required to have their installation teams trained to do installation 
of the G-6000 and antennas on high sited areas in order to meet the performance and regulatory requirements. 
This will require professional installation; the installation of the G-6000 must be controlled and installed by 
licensed professionals. Specially designed antennas and mounting procedures will be required and 
professional installation needed to ensure the equipment works reliably and compatibly with the complete 
ZyXEL infrastructure.   
5. An intentional radiator shall be designed to ensure that no antenna other than that furnished by the ZyXEL 
or its customer shall be used with the G-6000. The use of a permanently attached antenna or of an antenna 
that uses a unique coupling to the intentional radiator shall be considered sufficient to comply. If the unit 
becomes broken, the antenna can be replaced by the user, but the use of a standard antenna jack or electrical 
connector is prohibited. Further, this requirement does not apply to intentional radiators that must be 
professionally installed, such as perimeter protection systems and some field disturbance sensors, or to other 
intentional radiators which must be measured at the installation site. However, the installer shall be 
responsible for ensuring that the proper antenna is employed so that the limits in this part are not exceeded. 
6. This standard antenna may be used in a point-to-point application, and possibly may require a tower mount 
and/or directional antenna. Such use would be applicable in the following uses: data and control signal 
transmitter located in oil fields; transmitters mounted on trains and train stations; pole-mounted police and/or 
emergency vehicles. 
7. Permanent attachment of the G-6000 can be achieved by various means such as factory application of a 
permanent cement or epoxy to a standard antenna connector. The G-6000 will specify the certification 
application type of adhesive to be used and must confirm that the adhesive will be applied at the factory – 
prior to shipment. 
8. The installer must ensure that the G-6000 and antenna is properly installed so as not to exceed the limits for 
which it has been designed. 

Содержание G-6000

Страница 1: ...G 6000 High Speed Long Range Ethernet Wireless Bridge Ver 1 0 January 2005 Quick Start Guide...

Страница 2: ...Working with Configuration Windows System Setup 9 4 3 2 System Configuration Windows Software Download 12 4 3 3 System Log Windows 13 5 Hardware Installation 13 5 1 G 6000 office test 13 5 2 G 6000 P...

Страница 3: ...1 Physical connection of G 6000 for office test with flat panel antennas 14 Figure 5 2 Physical Installation of G 6000 with flat panel antenna 15 Figure 5 3 Mounting Bracket Assembly 16 Figure 5 4 At...

Страница 4: ...3 List of tables Table 3 1 Connectors of outdoor unit 7 Table 3 2 Connectors of indoor unit 7 Table 4 1 Default configuration 7 Table 4 2 Parameter description 12...

Страница 5: ...nd antennas on high sited areas in order to meet the performance and regulatory requirements This will require professional installation the installation of the G 6000 must be controlled and installed...

Страница 6: ...time 14 ZyXEL will provide all starter ingredients such as prototypes on a discounted basis to Widenet service providers for smooth transition and integration into existing client bases authorization...

Страница 7: ...robust IP66 approved enclosure and features a N type connector for external antenna connection A special weather proven connector is used for connecting the single STP cable to the indoor unit and spe...

Страница 8: ...5 cable to connect outdoor unit It has three ports Table 3 2 Connectors of indoor unit Function Name Connector Description Power POWER Power jack Connecting to the outdoor antenna Ethernet TO LAN RJ4...

Страница 9: ...r or Internet Explorer are examples of commonly used web browsers 2 From the PC enter the IP address that is assigned to the system as the URL address for example http 192 168 1 1 3 A dialog box appea...

Страница 10: ...uration tag on left top of the WEB window To access any of these system configuration screens click on the desired hotlink from the navigation bar in the Configuration screen 4 3 1 Working with Config...

Страница 11: ...arm to let you press the REBOOT to reboot system to make the changes effective 3 Click REBOOT to make the changes effective The web server loses connectivity with the Web Server as the system reboots...

Страница 12: ...cy list to find a used or less congested channel It only works on AP system AC will scan the right channel Data Rate Mbps Specifies rate of data transmission Select the desired rate from the drop down...

Страница 13: ...ess Specifies the default gateway for the unit Table 4 2 Parameter description 4 3 2 System Configuration Windows Software Download The Firmware Update configuration window allows users to view FTP lo...

Страница 14: ...ecify SNTP NTP server IP address in Configuration System Setup page there won t be any timestamp in system log The following lists all system logs in G 6000 Watch dog reboots system Firmware programmi...

Страница 15: ...14 Figure 5 1 Physical connection of G 6000 for office test with flat panel antennas...

Страница 16: ...Server U for throughput test Depending on user s application software The testing result varies from PC to PC 9 If the function is ok perform outdoor installation and testing 5 2 G 6000 Physical Conne...

Страница 17: ...bracket and the grounding wire to the back of the outdoor unit as shown in Figure 5 4 Figure 5 4 Attach the Mounting Bracket to Outdoor Unit 5 Fasten the mounting bracket assembly to install outdoor...

Страница 18: ...er unit Notice The antenna must be installed by the professional installer to comply with the safety electrical and radiation standards The installer should properly configure the output power of tran...

Страница 19: ...18 Figure 5 8 Connect Grounding wire to the outdoor unit...

Страница 20: ...port labeled as POWER on the network power injector Figure 5 9 Cable Connections of Network Power Injector 5 5 Initializing the G 6000 1 When plugging the switching power adapter into the 110V 220V wa...

Страница 21: ...ding After that call the installer on RU site to adjust the antenna in the same way After the RU site installer has completed the procedures the installer on BU site should fine tune the antenna posit...

Страница 22: ...ODU IDU connection fails END devices Init Fail BU init fails Memory Allocate Descriptor error H W Allocate Descriptor error BU Trap Monitor Task 5 9 RSSI LED Indication For easily configuring G 6000 r...

Страница 23: ...penetrate into the main unit from the connector The following procedures are recommendations for outdoor waterproof installation Step 1 Ensure that you already fasten all connectors tightly Step 2 Tig...

Отзывы: