background image

 
9. Compliance is required for special waterproofing procedures, insulation against lightening and other 
weather conditions. 
10. Also requires special mounting brackets for instillation in professional environments. 
11. Licensees will be recruited primarily from existing service providers and manufacturers that are already 
successful in Internet, paging, or mobile phone service industries. 
12. ZyXEL will provide products and services through service providers, its main sales strategies will be to 
empower service providers and to provide on-going service and support to service providers. Service 
providers will focus on local markets and offer flexible services to niche markets. 
13. Multiple service providers can be started with a relatively low cost of entry. ZyXEL will provide licensing 
companies already in the service industry (such as Internet, paging, or mobile telephone service companies), it 
will be possible to qualify and license service provides in a short space of time. 
14. ZyXEL will provide all starter ingredients (such as prototypes) on a discounted basis to Widenet service 
providers for smooth transition and integration into existing client bases, authorization, and billing. 
15. All equipment will be sold only to ZyXEL qualified network operators that will be purchasing the 
equipment as a part of an infrastructure to provide services. The intended use and design of the G-6000 is for 
use by utility companies, large telecom corporations to build out or compliment their current infrastructure for 
radio frequency and telecommunications signaling. 

 

3. Hardware Description 

The G-6000 is composed of outdoor and indoor unit which are connected by a single Ethernet cable.   

3.1. Packing 

list 

a.

 

Outdoor Unit 

b.

 

Network Power injector 

c.

 

HDF 400 RF coaxial cable 

d.

 

20m Cat-5 STP cable with special waterproof connector 

e.

 

Mounting bracket 

f.

 

power adaptor 

g.

 

CAT-5 Straight-through Ethernet cable 

h.

 

RS-232 cable 

i.

 

Grounding wire 

j.

 

Quick installation guide 

k.

 

Supporting CD 

l.

 

antenna alignment kit 

Optional components 

m.

 

22 dBi antenna 

n.

 

50m Cat-5 STP cable with special waterproof connector 

o.

 

90m Cat-5 STP cable with special waterproof connector 

 
 
 
 
 

Содержание G-6000

Страница 1: ...G 6000 High Speed Long Range Ethernet Wireless Bridge Ver 1 0 January 2005 Quick Start Guide...

Страница 2: ...Working with Configuration Windows System Setup 9 4 3 2 System Configuration Windows Software Download 12 4 3 3 System Log Windows 13 5 Hardware Installation 13 5 1 G 6000 office test 13 5 2 G 6000 P...

Страница 3: ...1 Physical connection of G 6000 for office test with flat panel antennas 14 Figure 5 2 Physical Installation of G 6000 with flat panel antenna 15 Figure 5 3 Mounting Bracket Assembly 16 Figure 5 4 At...

Страница 4: ...3 List of tables Table 3 1 Connectors of outdoor unit 7 Table 3 2 Connectors of indoor unit 7 Table 4 1 Default configuration 7 Table 4 2 Parameter description 12...

Страница 5: ...nd antennas on high sited areas in order to meet the performance and regulatory requirements This will require professional installation the installation of the G 6000 must be controlled and installed...

Страница 6: ...time 14 ZyXEL will provide all starter ingredients such as prototypes on a discounted basis to Widenet service providers for smooth transition and integration into existing client bases authorization...

Страница 7: ...robust IP66 approved enclosure and features a N type connector for external antenna connection A special weather proven connector is used for connecting the single STP cable to the indoor unit and spe...

Страница 8: ...5 cable to connect outdoor unit It has three ports Table 3 2 Connectors of indoor unit Function Name Connector Description Power POWER Power jack Connecting to the outdoor antenna Ethernet TO LAN RJ4...

Страница 9: ...r or Internet Explorer are examples of commonly used web browsers 2 From the PC enter the IP address that is assigned to the system as the URL address for example http 192 168 1 1 3 A dialog box appea...

Страница 10: ...uration tag on left top of the WEB window To access any of these system configuration screens click on the desired hotlink from the navigation bar in the Configuration screen 4 3 1 Working with Config...

Страница 11: ...arm to let you press the REBOOT to reboot system to make the changes effective 3 Click REBOOT to make the changes effective The web server loses connectivity with the Web Server as the system reboots...

Страница 12: ...cy list to find a used or less congested channel It only works on AP system AC will scan the right channel Data Rate Mbps Specifies rate of data transmission Select the desired rate from the drop down...

Страница 13: ...ess Specifies the default gateway for the unit Table 4 2 Parameter description 4 3 2 System Configuration Windows Software Download The Firmware Update configuration window allows users to view FTP lo...

Страница 14: ...ecify SNTP NTP server IP address in Configuration System Setup page there won t be any timestamp in system log The following lists all system logs in G 6000 Watch dog reboots system Firmware programmi...

Страница 15: ...14 Figure 5 1 Physical connection of G 6000 for office test with flat panel antennas...

Страница 16: ...Server U for throughput test Depending on user s application software The testing result varies from PC to PC 9 If the function is ok perform outdoor installation and testing 5 2 G 6000 Physical Conne...

Страница 17: ...bracket and the grounding wire to the back of the outdoor unit as shown in Figure 5 4 Figure 5 4 Attach the Mounting Bracket to Outdoor Unit 5 Fasten the mounting bracket assembly to install outdoor...

Страница 18: ...er unit Notice The antenna must be installed by the professional installer to comply with the safety electrical and radiation standards The installer should properly configure the output power of tran...

Страница 19: ...18 Figure 5 8 Connect Grounding wire to the outdoor unit...

Страница 20: ...port labeled as POWER on the network power injector Figure 5 9 Cable Connections of Network Power Injector 5 5 Initializing the G 6000 1 When plugging the switching power adapter into the 110V 220V wa...

Страница 21: ...ding After that call the installer on RU site to adjust the antenna in the same way After the RU site installer has completed the procedures the installer on BU site should fine tune the antenna posit...

Страница 22: ...ODU IDU connection fails END devices Init Fail BU init fails Memory Allocate Descriptor error H W Allocate Descriptor error BU Trap Monitor Task 5 9 RSSI LED Indication For easily configuring G 6000 r...

Страница 23: ...penetrate into the main unit from the connector The following procedures are recommendations for outdoor waterproof installation Step 1 Ensure that you already fasten all connectors tightly Step 2 Tig...

Отзывы: