Problem
Corrective Action
“Device Not Communicating” posted in plumbSMART
Step 1
Verify LoRa Monitor electronics are plugged in / Verify batteries
installed in LoRa Monitor electronics and have sufficient charge
(whichever applies). Install new batteries, as needed. Alert on
product’s page in plumbSMART should clear within 1 hour or on
next faucet activation. (Refresh web page by clicking on reload
icon in the browser to clear the alert.)
Step 2
If problem still present, verify gateway is within range of LoRa
Monitor and functioning (see Gateway Troubleshooting section)
Step 3
If problem is still present, verify plumbSMART subscription
status on product page’s Details tab is listed as “Activated”
NETWORK:
Senet
SUBSCRIPTION STATUS:
Activated
LAST HEARD FROM:
07/14/2020, 04:29 PM CDT
If listed as “Deactivated”, contact Zurn Customer Service at
1.855.ONE.ZURN (1.855.663.9876) for assistance.
“Status – Good” posted in plumbSMART and faucet not
actuating
Step 1
Verify LoRa Monitor’s cables are connected to IR sensor
and Faucet actuator electronics. Restore proper electrical
connection, as needed.
Step 2
Test activate the faucet.
If problem persists, see Faucet Troubleshooting section in this
guide for other steps.
“Status – Good” posted in plumbSMART and faucet actuates but
usage event data not appearing in plumbSMART Charts
Step 1
Verify gateway is powered and LoRa Status LED is ON. If not,
apply power per Zurn Gateway Installation Guide or see
Gateway Troubleshooting section in this guide for other steps.
Step 2
If problem still present, verify plumbSMART subscription status
on product page’s Details tab listed as “Activated”
NETWORK:
Senet
SUBSCRIPTION STATUS:
Activated
LAST HEARD FROM:
07/14/2020, 04:29 PM CDT
If listed as “Deactivated”, contact Zurn Customer Service at
1.855.ONE.ZURN (1.855.663.9876) for assistance.
Step 3
If problem still present, the LoRa Monitor electronics may be
faulty. Contact Zurn Customer Service at 1.855.ONE.ZURN
(1.855.663.9876) for assistance with additional troubleshooting
steps and, if needed, unit replacement.
Trouble Shooting: LoRa Monitor (-W1/-W2)
For further assistance with troubleshooting, visit https://plumbsmart.zurn.com/app/training