TROUBLESHOOTING GUIDE: 

Care and Cleaning Instructions: 

• Do not use any abrasive or chemical cleaners to clean the faucets.

• 

If abrasives or chemicals are used it can lead to dulling of luster, attacking of chrome plating or decorative finishes.

• ONLY use mildly warm soapy water, and then wipe the device dry with a clean/soft towel or cloth.

• Upon cleaning other areas of the restroom be sure the sensor lenses are protected from other cleaning chemicals/solvents to prevent 

potential damages to the sensor and/or electronics.

For further assistance with troubleshooting visit http://www.zurn.com

POTENTIAL SITUATIONS

POSSIBLE CAUSES

SUGGESTED SOLUTION TIPS

Faucet is non-responsive

Battery voltage low or no power

Change out batteries or verify power provided by HW6 or ACA

Sensor and electronic connector cable has bent or 

broken pins

Check to see if pins are missing, bent, or broken. If yes, then the 

electronic box needs replaced

Sensor lens could have surface damage, 

scratches, or deposit build ups

Inspect the sensor lens underneath the spout tip.  May require 

cleaning with a damp cloth or sensor replacement

Sensor lens could be obstructed by environmental 

factors such as high reflective surfaces or bright 

lighting conditions

If this is the case, then adjust the dip switch settings for sensor 

sensitivity per the diagram on previous page (switches 7 and 8).  

Direct sunlight into bowl may make the unit inoperable.  Do not 

allow direct sunlight into bowl

Faucet does not activate 

after initial installation

Sensor may not have had enough time to calibrate 

prior to a user or target trying to initiate activation

Disconnect the sensor and electronic box cables and wait for 30 

seconds. Reconnect the cables, then wait until the water stops 

flowing water (up to one (1) minute) before placing hands or a 

target within the sensor range. You should hear a click of the 

solenoid once calibration is complete.

Water does not stop

Electronics box cable connector has bent pins that 

are shorted

Check to see if pins are missing, bent, or broken. If yes, then the 

electronic box needs replaced.

Ghost Activation

Sensor lens could be obstructed or environmental 

factors such as high reflective surfaces and/or 

bright sunlight conditions

“Check/clean sensor lens of any debris or buildup 

If sunlight or IR interference is a factor, refer to page 7 “”Sensor 

Sensitivity”” and adjust faucet for Mode B operation.”

Sensor faucet is leaking un-

derneath the sink or counter

Mounting hardware is not tightened sufficiently 

(faucet shank, electronic box, supply hoses, etc)

Check and ensure the nuts and joints are tight and secure from 

the supply stop all the way to the faucet shank.

Missing the washer located in the solenoid box nut 

where it assembles to the faucet shank.

Make sure the water supply stops are shut off. Check to ensure 

the washer is installed or damaged. If not, install washer.  If a 

washer is installed replace with new.

Содержание HYDRO-X Power Serio Series

Страница 1: ...ury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assume all risk and liability whatever in connection therewith Where permitted by law the implied warranty of m...

Страница 2: ...This Page Intentionally Left Blank ...

Страница 3: ...se Gasket Base Gasket Spout Assembly Aerator and Key Shank Mounting Kit Shank Mounting Kit Electronics Box with Solenoid Valve Electronics Box with Solenoid Valve Electronics Box with Solenoid Valve Aerator and Key Shank Mounting Kit Base Gasket Spout Assembly Filter Filter Filter Filter Batteries Batteries Batteries Widespread Mounting Kit Mixing Yoke Sensor Inline Connector Sensor Inline Connect...

Страница 4: ...the product is installed and conforms to all plumbing codes and ordinances Do not convert or modify this Zurn product yourself All warranties will be voided Water supply lines must be sized according to building designer in order to provide adequate water supply for each fixture Flush all water lines prior to making connections Prior to Installation Before installing your Zurn Serio Series Faucet ...

Страница 5: ...ream of electronics module B and filter C to bottom of electronics module Sensor cable should not pass through plastic mounting washer NOTE Before installation turn off water supplies to existing faucet and remove faucet if replacing an existing device Clean the faucet basin and clear away debris Flush all supply lines before connecting the faucet Failure to do so may result in debris clogging the...

Страница 6: ...erminals on HW6 unit the BLACK WITH DASHED MARKINGS should be connected to the Positive terminal and the SOLID BLACK wire should be connected to the Negative terminal BLUE GREEN YELLOW FRAME SAFETY GROUND P6000 HW6 WIRING IN VAC LINE BLACK NEUTRAL WHITE RED INLINE CONNECTOR CWB HW6 ACA MJ unit sold separately Note Do not connect more than 8 solenoids to a single transformer BLUE GREEN YELLOW FRAME...

Страница 7: ...e connection is made do not engage the sensor until its self calibration is complete The sensor s self calibration is complete once the faucet stops flowing water The sensor s self calibration can take up to one 1 minute after the connection is made 2 5 Tighten electronics module assembly with hydrogenerator to shank and connect water line s 2 5 a For IM assembly tighten mixing yoke with electroni...

Страница 8: ... used for varied sink and environmental conditions The factory default setting should be ideal for most general applications However sensor performance can be optimized to adjust for unusual sink finish material shape or unusually bright or dark lighting conditions Switch 7 controls the sensitivity On default is normal sensitivity for most sinks providing max range Off set the sensor to a lower se...

Страница 9: ... page switches 7 and 8 Direct sunlight into bowl may make the unit inoperable Do not allow direct sunlight into bowl Faucet does not activate after initial installation Sensor may not have had enough time to calibrate prior to a user or target trying to initiate activation Disconnect the sensor and electronic box cables and wait for 30 seconds Reconnect the cables then wait until the water stops f...

Страница 10: ...ent is between the 2 holes Press down and turn clockwise Use hex wrench to back set screw out to secure spout To reinstall faucet first drop sensor cable of new spout through the front of the base Lower spout onto base inserting base nipple into spout port To replace spout body you must first turn water off then remove spout with sensor cable Note location of set screw and spring lock Spout Replac...

Страница 11: ...ket Item 12 P6950 CP8 Z6950 Sensor Assembly Item 13 P6950 XL EL Sensor Inline Connector Item 14 P6950 XL DC IM Solenoid Y Connector Item 15 P6950 XL YC Optional Plug in Power Converter Item 16 P6900 ACA HW6 Power Supply Item 17 P6900 HW6 Filter Kit Item 18 P6900 120BC Filter Screen Item 19 P6900 MV 7 Mixing Valve with Filter Item 20 P6900 XL MV Composite Mixing Valve Adapter Item 21 P6900 MV ADAP ...

Страница 12: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 05 21 21 C N No 143760 Prod Dwg No FV794 ...

Отзывы: