Sensor-Operated Battery-Powered

Lavatory Faucets

Serio Series™ Faucet

Sensor-Operated Lavatory Faucets  

for Battery or Plug-In Installations.
Installation, Operation, Maintenance, 

and Parts Manual

Patented and Patents Pending

Z6950-XL-S

Z6955-XL-S

Z6950-XL-IM-S*

LIMITED WARRANTY

All goods sold hereunder are warranted to be free from defects in material and factory workmanship for a period of three years from the 

date of purchase. Decorative finishes warranted for one year. We will replace at no costs goods that prove defective provided we are 

notified in writing of such defect and the goods are returned to us prepaid at Sanford, NC, with evidence that they have been properly 

maintained and used in accordance with instructions. We shall not be responsible for any labor charges or any loss, injury or damages 

whatsoever, including incidental or consequential damages. The sole and exclusive remedy shall be limited to the replacement of the 

defective goods. Before installation and use, the purchaser shall determine the suitability of the product for his intended use and the 

purchaser assume all risk and liability whatever in connection therewith. Where permitted by law, the implied warranty of merchantability 

is expressly excluded. If the products sold hereunder are “consumer products,” the implied warranty of merchantability is limited to a 

period of three years and shall be limited solely to the replacement of the defective goods. All weights stated in our catalogs and listed 

are approximate and are not guaranteed.

WARNING

: Cancer and Reproductive Harm - www.P65Warnings.ca.gov

ADVERTENCIA: 

Cáncer y daño reproductivo - www.P65Warnings.ca.gov

AVERTISSEMENT: 

Cancer et effets néfastes sur la reproduction - www.P65Warnings.ca.gov

NOTE: The information in this manual is subject to change at any time without notice. Installations may 

be performed at different times of construction by different individuals. For this reason, these instructions 

should be left on-site with the facility or maintenance manager.

NOTICE: READ ENTIRE MANUAL PRIOR TO INSTALLING PRODUCT.

*HYDRO-X Power not included with integral mixer (IM) faucets.  

Содержание HYDRO-X Power Serio Series

Страница 1: ...ury or damages whatsoever including incidental or consequential damages The sole and exclusive remedy shall be limited to the replacement of the defective goods Before installation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assume all risk and liability whatever in connection therewith Where permitted by law the implied warranty of m...

Страница 2: ...This Page Intentionally Left Blank ...

Страница 3: ...se Gasket Base Gasket Spout Assembly Aerator and Key Shank Mounting Kit Shank Mounting Kit Electronics Box with Solenoid Valve Electronics Box with Solenoid Valve Electronics Box with Solenoid Valve Aerator and Key Shank Mounting Kit Base Gasket Spout Assembly Filter Filter Filter Filter Batteries Batteries Batteries Widespread Mounting Kit Mixing Yoke Sensor Inline Connector Sensor Inline Connect...

Страница 4: ...the product is installed and conforms to all plumbing codes and ordinances Do not convert or modify this Zurn product yourself All warranties will be voided Water supply lines must be sized according to building designer in order to provide adequate water supply for each fixture Flush all water lines prior to making connections Prior to Installation Before installing your Zurn Serio Series Faucet ...

Страница 5: ...ream of electronics module B and filter C to bottom of electronics module Sensor cable should not pass through plastic mounting washer NOTE Before installation turn off water supplies to existing faucet and remove faucet if replacing an existing device Clean the faucet basin and clear away debris Flush all supply lines before connecting the faucet Failure to do so may result in debris clogging the...

Страница 6: ...erminals on HW6 unit the BLACK WITH DASHED MARKINGS should be connected to the Positive terminal and the SOLID BLACK wire should be connected to the Negative terminal BLUE GREEN YELLOW FRAME SAFETY GROUND P6000 HW6 WIRING IN VAC LINE BLACK NEUTRAL WHITE RED INLINE CONNECTOR CWB HW6 ACA MJ unit sold separately Note Do not connect more than 8 solenoids to a single transformer BLUE GREEN YELLOW FRAME...

Страница 7: ...e connection is made do not engage the sensor until its self calibration is complete The sensor s self calibration is complete once the faucet stops flowing water The sensor s self calibration can take up to one 1 minute after the connection is made 2 5 Tighten electronics module assembly with hydrogenerator to shank and connect water line s 2 5 a For IM assembly tighten mixing yoke with electroni...

Страница 8: ... used for varied sink and environmental conditions The factory default setting should be ideal for most general applications However sensor performance can be optimized to adjust for unusual sink finish material shape or unusually bright or dark lighting conditions Switch 7 controls the sensitivity On default is normal sensitivity for most sinks providing max range Off set the sensor to a lower se...

Страница 9: ... page switches 7 and 8 Direct sunlight into bowl may make the unit inoperable Do not allow direct sunlight into bowl Faucet does not activate after initial installation Sensor may not have had enough time to calibrate prior to a user or target trying to initiate activation Disconnect the sensor and electronic box cables and wait for 30 seconds Reconnect the cables then wait until the water stops f...

Страница 10: ...ent is between the 2 holes Press down and turn clockwise Use hex wrench to back set screw out to secure spout To reinstall faucet first drop sensor cable of new spout through the front of the base Lower spout onto base inserting base nipple into spout port To replace spout body you must first turn water off then remove spout with sensor cable Note location of set screw and spring lock Spout Replac...

Страница 11: ...ket Item 12 P6950 CP8 Z6950 Sensor Assembly Item 13 P6950 XL EL Sensor Inline Connector Item 14 P6950 XL DC IM Solenoid Y Connector Item 15 P6950 XL YC Optional Plug in Power Converter Item 16 P6900 ACA HW6 Power Supply Item 17 P6900 HW6 Filter Kit Item 18 P6900 120BC Filter Screen Item 19 P6900 MV 7 Mixing Valve with Filter Item 20 P6900 XL MV Composite Mixing Valve Adapter Item 21 P6900 MV ADAP ...

Страница 12: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 05 21 21 C N No 143760 Prod Dwg No FV794 ...

Отзывы: