background image

FV744 Rev.  A 01/20/21

Page 14

    

FV744 Rev.  A 01/20/21

Page 13

   

 

P6900-120BC, 

Filter in standard faucet installation

Control Box

Attach adapter or Braided Hose (-SSH)

here with -MV  and TMV-1 options

-SSH suffix option

P6900-12BC Filter

Need to hold at pointed area by suitable

wrench or by hand while applying torque

to the supply hose nut.

Do not over torque the nut.

P6900-MV-ADAP [Supplied Adapter] 

with -MV Option

To Control Box

-SSH Option

Supplied

Adapter

3/8 Copper 

Tube (By Others)

For use with

-MV Option

Mixing Valve

Filter and Mixing Valve Installation

15

16

8

9

10

14

3B

4A

5

Z6920-XL-W2 & Z6922-XL-W2 Parts List

Description

Product No.

5 3/8” Gooseneck Spout with Nut, Item 1

P6900-GB

1.5 GPM Vandal Resistant Laminar Aerator, 

Item 2

P6900-20J-GN

Z6920 No Lead Spout Base with Sensor 

Assembly, Item 3A

P6920-XL-2

Z6922 N

o Lead Spout Base with Sensor 

Assembly, Item 3B

P6922-XL-2

Z6920 Mounting Kit, Item 4A

P6920-43

Z6922 Mounting Kit, Item 4B

P6920-43

Smart Connected Faucet Retrofit Kit, 

Item 5

P6900-RK-W2

Description

Product No.

Filter Kit,  Item 8

P6900-120BC

Filter Screen,  Item 9

P6900-MV-7

Mixing Valve with Filter, Item 10

P6900-XL-MV

Single Stainless Supply Hose (XL),  Item 12

P6900-SSH

Stainless Supply Hose (XL),  Item 13

P6900-SH-XL

Composite Mixing Valve Adapter,  Item 14

P6900-MV-ADAP

Shank Connection Gasket,  Item 15

P6900-SG

Solenoid Rebuilt Kit (Diaphragm, Plunger 

 

and Plunger spring),  Item 16

P6950-SRK

Electronics Box with Solenoid, Item 17

P6950-XL-B-L

1

2

4B

2

1

3A

17

17

Содержание AquaSense Z6920-XL-W2

Страница 1: ... of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective g...

Страница 2: ...For this reason these instructions should be left on site with the facility or maintenance manager Specifications Voltage 6 VDC Series 4 AA Alkaline or Lithium for faucet 4 VDC Series 4 AA Alkaline or Lithium for monitor Sensor Range Self calibrated dependent upon sink depth and finish Operating Water Pressure 10 125 psi Operational Water Temperature 33 F to 140 F 1 C to 60 C Aerator 1 5 GPM Vanda...

Страница 3: ...lastic mounting washer 4 Assemble the electronics module Do not connect the electronic module to spout Spout Installation Instructions Cable to monitor 1 Install Monitor on wall surface within 2 feet radius of faucet with dry wall anchors screws or doubled sided VHB tape 2 Loosen lid screw with supplied 3mm Allen wrench Open lid and install supplied batteries Close lid and tighten lid screw 5 Tigh...

Страница 4: ...eway is now ready to transmit data from your Zurn connected product 4 Zurn Gateways have been set to DHCP by default Please consult local IT support for possible additional access requirements for your network Step 3 Determining general Location for the Zurn Gateway Select a location central to all devices to be connected to this gateway Place the gateway as high as possible such as near the top o...

Страница 5: ...Off Off Off Off Off Off On On Mode Select Sensing Mode Metering Mode Off On Sensor Sensitivity Low Off Normal On Mode A Off Mode B On Adjustable modes and features selection For further assistance with troubleshooting visit http www zurn com Problem Possible Cause Corrective Action Faucet is non responsive Battery voltage low or no power Change out batteries or verify power provided by ACA Sensor ...

Страница 6: ...should clear within 1 hour or on next faucet activation Refresh web page by clicking on reload icon in the browser to clear the alert Step 2 If problem still present verify gateway is within range of LoRa Monitor and functioning see Gateway Troubleshooting section Step 3 If problem still present verify plumbSMART subscription status on product page s Details tab listed as Activated NETWORK Senet S...

Страница 7: ...t data is properly presented in Chart Step 3 If problem still present contact building maintenance to verify sufficient water pressure in lines Step 4 If problem persists the LoRa Monitor may be paired to the incorrect fixture model Verify product image and model number from plumbSMART product page Details tab against model number cited on product literature and packaging If incorrect contact Zurn...

Страница 8: ...3 8 Gooseneck Spout with Nut Item 1 P6900 GB 1 5 GPM Vandal Resistant Laminar Aerator Item 2 P6900 20J GN Z6920 No Lead Spout Base with Sensor Assembly Item 3A P6920 XL 2 Z6922 No Lead Spout Base with Sensor Assembly Item 3B P6922 XL 2 Z6920 Mounting Kit Item 4A P6920 43 Z6922 Mounting Kit Item 4B P6920 43 Smart Connected Faucet Retrofit Kit Item 5 P6900 RK W2 Description Product No Filter Kit Ite...

Страница 9: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 01 20 21 C N No 143366 Prod Dwg No FV744 ...

Отзывы: