FV744 Rev.  A 01/20/21

Page 12

    

FV744 Rev.  A 01/20/21

Page 11

   

 

To service solenoid use Phillips head screw driver to remove the 

screws on both sides of the electronics box.

With screws removed, the electronics box can slide off and allow 

access to the solenoid for service.

Turn the spout nut to loosen the spout for removal.

Lift spout up to remove spout.

To replace spout body, you must first turn water off, then remove spout.

Spout Replacement

Accessing the Solenoid

Problem

Corrective Action

Usage data presented in Water Usage Chart does not match 

expected usage.

Step 1

Confirm installed aerator model’s gallons/minute specification 

matches parameter setting in plumbSMART product page 

“Parameters” tab.  If factory-original aerator is installed, reset 

parameter value to factory default and click Update.

Step 2

Test activate the faucet and confirm single usage event data is 

properly presented in Chart

Step 3 

If problem still present, contact building maintenance to verify 

sufficient water pressure in lines.

Step 4

If problem persists, the LoRa Monitor may be paired to the 

incorrect fixture model.  Verify product image and model 

number from plumbSMART product page “Details” tab against 

model number cited on product literature and packaging.

If incorrect, contact Zurn Custom Service at 1.855.ONE.ZURN 

(1.855.663.9876) for assistance.

“High Daily Faucet Activate Rate” posted in plumbSMART

Step 1

Verify faucet is not falsely triggering.  See Faucet 

Troubleshooting section for appropriate diagnostic steps.

Step 2 

Test activate the faucet and confirm single usage event data is 

properly presented in Chart.

If problem persists, see Faucet Troubleshooting section in this 

guide for additional steps.

LoRa Monitor not listed in plumbSMART.

Step 1

Follow registration steps in plumbSMART to activate the 

connected product.

Trouble Shooting: plumbSMART

For further assistance with troubleshooting, visit https://plumbsmart.zurn.com/app/training

Содержание AquaSense Z6920-XL-W2

Страница 1: ... of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and shall be limited solely to the replacement of the defective g...

Страница 2: ...For this reason these instructions should be left on site with the facility or maintenance manager Specifications Voltage 6 VDC Series 4 AA Alkaline or Lithium for faucet 4 VDC Series 4 AA Alkaline or Lithium for monitor Sensor Range Self calibrated dependent upon sink depth and finish Operating Water Pressure 10 125 psi Operational Water Temperature 33 F to 140 F 1 C to 60 C Aerator 1 5 GPM Vanda...

Страница 3: ...lastic mounting washer 4 Assemble the electronics module Do not connect the electronic module to spout Spout Installation Instructions Cable to monitor 1 Install Monitor on wall surface within 2 feet radius of faucet with dry wall anchors screws or doubled sided VHB tape 2 Loosen lid screw with supplied 3mm Allen wrench Open lid and install supplied batteries Close lid and tighten lid screw 5 Tigh...

Страница 4: ...eway is now ready to transmit data from your Zurn connected product 4 Zurn Gateways have been set to DHCP by default Please consult local IT support for possible additional access requirements for your network Step 3 Determining general Location for the Zurn Gateway Select a location central to all devices to be connected to this gateway Place the gateway as high as possible such as near the top o...

Страница 5: ...Off Off Off Off Off Off On On Mode Select Sensing Mode Metering Mode Off On Sensor Sensitivity Low Off Normal On Mode A Off Mode B On Adjustable modes and features selection For further assistance with troubleshooting visit http www zurn com Problem Possible Cause Corrective Action Faucet is non responsive Battery voltage low or no power Change out batteries or verify power provided by ACA Sensor ...

Страница 6: ...should clear within 1 hour or on next faucet activation Refresh web page by clicking on reload icon in the browser to clear the alert Step 2 If problem still present verify gateway is within range of LoRa Monitor and functioning see Gateway Troubleshooting section Step 3 If problem still present verify plumbSMART subscription status on product page s Details tab listed as Activated NETWORK Senet S...

Страница 7: ...t data is properly presented in Chart Step 3 If problem still present contact building maintenance to verify sufficient water pressure in lines Step 4 If problem persists the LoRa Monitor may be paired to the incorrect fixture model Verify product image and model number from plumbSMART product page Details tab against model number cited on product literature and packaging If incorrect contact Zurn...

Страница 8: ...3 8 Gooseneck Spout with Nut Item 1 P6900 GB 1 5 GPM Vandal Resistant Laminar Aerator Item 2 P6900 20J GN Z6920 No Lead Spout Base with Sensor Assembly Item 3A P6920 XL 2 Z6922 No Lead Spout Base with Sensor Assembly Item 3B P6922 XL 2 Z6920 Mounting Kit Item 4A P6920 43 Z6922 Mounting Kit Item 4B P6920 43 Smart Connected Faucet Retrofit Kit Item 5 P6900 RK W2 Description Product No Filter Kit Ite...

Страница 9: ...TRIES LLC 511 W Freshwater Way Milwaukee WI U S A 53204 Ph 1 855 ONE ZURN Fax 919 775 3541 In Canada ZURN INDUSTRIES LIMITED 7900 Goreway Drive Unit 10 Brampton Ontario L6T 5W6 Ph 905 405 8272 Fax 905 405 1292 Rev A Date 01 20 21 C N No 143366 Prod Dwg No FV744 ...

Отзывы: