FV38 Rev. D 2/27/12
Page 3
PRIOR TO INSTALLATION
Prior to installing the Zurn Automatic Sensor-equipped
Flushometer, install the items listed below as illustrated in
Figures 1 through 3.
• 2-gang electrical box (4 x 4 x 2 1/8, use Steel City #52171-N
box, and #52-C-18 device cover or equivalent for sensor
with closet installs, or #52-C-14 reducing device or
equivalent for sensor with urinal installs);
• Single-gang electrical outlet for plug-in power converter.
• Electrical wiring to the power converter outlet (120 VAC, 35
watts service required for each power converter used).
• Closet fixture.
• Zurn carrier system, Z1200 series or equal.
IMPORTANT:
• All electrical wiring is to be installed in accordance with National/Local codes and regulations.
• All plumbing is to be installed in accordance with applicable codes and regulations.
• Water supply lines must be sized to provide an adequate volume of water for each fixture.
• Flush all water lines prior to making connections.
• Sensor units should not be located across from each other or in close proximity to highly reflective surfaces.
• Control Stop should never be opened to allow flow greater than fixture is capable of evacuating. In the event of valve failure,
fixture must be able to handle a continuous flow.
Model ZEMS6190
Model ZEMS6195
Model ZEMS6197
3
4
[19]
VACUUM
BREAKER
TUBE
13
1
2
[343]
4
[102]
4
3
4
[121]
MOTOR
ACTUATOR
SENSOR
3
4
" I.P.S.
SUPPLY
10
3
4
[273] MAX.
3
3
4
[95] MIN.
AS SPECIFIED
TOP OF
FIXTURE
3
4
[19]
VACUUM
BREAKER
TUBE
13
1
2
[343]
10
[254]
4
3
4
[121]
MOTOR
ACTUATOR
SENSOR
3
4
" I.P.S.
SUPPLY
10
3
4
[273] MAX.
3
3
4
[95] MIN.
AS SPECIFIED
TOP OF
FIXTURE