FV38 Rev. D 2/27/12
Page 4
Notes:
1. Failure to observe proper polarity will result in faulure of
the sensor and/or power converter.
2. Use #18 AWG for interconnections.
Electrical Hook-up
(Figure 1)
Be certain power is off to prevent damage to electrical components. Connect the sensor to the actuator and power converter
exactly as shown in Figure 1.
Double check that power converter polarity is correct.
Figure 1
ACTUATOR
BRN
GRN
BLU
BRN
GRN
BLU
PB
PB
PB
ACTUATOR
ACTUATOR
SENSOR
SENSOR
SENSOR
HW6
(-)
BLACK
BLACK/WHITE STRIPE
(+)
PLUG-IN POWER
CONVERTER
120 VAC IN
6 VDC OUT
MANUAL OVERRIDE
PUSHBUTTONS
(-)
(+)
Electrical
AC/DC Power Supply
Install hardwired power supply or receptacle for the Zurn Power Converter in a convenient location. An optional mini junction
box (P6000-MJ) is recommended to distribute power to each sensor location. It is also recommended that brown wire be used
for the DC positive (+) of the supply and blue wire be used for the DC negative (-) of the supply. This matches the sensor and
actuator wire colors.
NOTE:
One Zurn P6000-HW6 or P6000-PC6 Power Converter can operate as many as eight Automatic Sensor equipped
Flushometers. The Power Converter is supplied with a six-foot cord. If additional wire is needed from the Power Converter to
the Flushometer(s), use #18 AWG for this (by others).
Do not supply power
to the Power Converter until installation of actuator,
sensor and Flushometer is completed and checked.
Proper polarity must be observed or damage to one or all components
will result.
Maximum of
8 actuators
allowable
P6000-MJ
Optional Mini
Junction Box
Figure 2
(Power Distribution)
RED
VDC
BLUE
GND
CA
UT
IO
N:
R
ISK O
F
EL
EC
T
R
IC
SH
O
C
K
DR
Y
L
O
CA
T
IO
N
US
E
O
N
L
Y
R
REGULATED POWER SUPPLY
PART NO : 2000970 01
MODEL NO : P6000-HW6
I/P : 120 VAC/320mA@Full load, 60Hz
O/P : + 7.6.0VDCmin@2A load
DUTY CYCLE : 2 sec
"
On
"
, 60sec
"
Off
"
Delta El ectronics (T hailand) Pub lic Co.,Ltd.
7.6 V DC
O UT
BLACK
BLACK w ith
WHITE S TRIPE
BLUE (-)
RED (+)
WH ITE
BLACK
120 V AC
IN
P6000-HW6 WIRING
TO FAU CET
O R FLUS H VALVE
E323 1 68
MADE IN TH AILAND
C
US
UL
®
"Us e Co ppe r c ond ucto r o nly a nd
se e d eta ils in ins tru ctioin ma nua l"
"For Gr oun din g Co ndu cto r, Use 18
AWG min im um "
WA
R
N
IN
G
:
T
o
re
duc
e r
is
k
of
f
ir
e
or
el
ec
tr
ic
sh
oc
k
-
D
o
n
o
t i
n
te
rc
on
nec
t
ou
tp
ut
t
e
rm
in
at
io
ns
.
SENSOR AND
4 X 4 BOX
MOTOR
ACTUATOR
HW6
FIXTURE
BOX CLAMP
CABLE
ARMOR
FINISHED WALL
120 VAC/60Hz
Service
P6000-HW6