FV38  Rev. D  2/27/12
Page 4

Notes:
1. Failure to observe proper polarity will result in faulure of

the sensor and/or power converter.

2. Use #18 AWG for interconnections.

Electrical Hook-up 

(Figure 1)

Be certain power is off to prevent damage to electrical components.  Connect the sensor to the actuator and power converter
exactly as shown in Figure 1.

Double check that power converter polarity is correct.

Figure 1

ACTUATOR

BRN

GRN

BLU

BRN

GRN

BLU

PB

PB

PB

ACTUATOR

ACTUATOR

SENSOR

SENSOR

SENSOR

HW6

(-)
BLACK

BLACK/WHITE STRIPE
(+)

PLUG-IN POWER
CONVERTER
120 VAC IN
6 VDC OUT

MANUAL OVERRIDE
PUSHBUTTONS

(-)

(+)

Electrical

AC/DC Power Supply

Install hardwired power supply or receptacle for the Zurn Power Converter in a convenient location. An optional mini junction
box (P6000-MJ) is recommended to distribute power to each sensor location. It is also recommended that brown wire be used
for the DC positive (+) of the supply and blue wire be used for the DC negative (-) of the supply. This matches the sensor and
actuator wire colors.

NOTE: 

One Zurn P6000-HW6 or P6000-PC6 Power Converter can operate as many as eight Automatic Sensor equipped

Flushometers. The Power Converter is supplied with a six-foot cord. If additional wire is needed from the Power Converter to
the Flushometer(s), use #18 AWG for this (by others). 

Do not supply power 

to the Power Converter until installation of actuator,

sensor and Flushometer is completed and checked. 

Proper polarity must be observed or damage to one or all components

will result.

Maximum of
8 actuators
allowable

P6000-MJ
Optional Mini
Junction Box

Figure 2
(Power Distribution)

RED

VDC

BLUE

GND

CA

UT

IO

N:

R

ISK O

F

 EL

EC

T

R

IC

 SH

O

C

K

DR

Y

 L

O

CA

T

IO

N

 US

E

 O

N

L

Y

R

REGULATED POWER  SUPPLY
PART  NO  : 2000970 01
MODEL NO  : P6000-HW6
I/P : 120 VAC/320mA@Full  load, 60Hz
O/P : + 7.6.0VDCmin@2A load
DUTY  CYCLE : 2 sec 

"

On

"

, 60sec 

"

Off

"

Delta El ectronics (T hailand) Pub lic Co.,Ltd.

7.6 V DC
O UT

BLACK

BLACK  w ith
WHITE  S TRIPE

BLUE (-)

RED  (+)

WH ITE

BLACK

120 V AC
      IN

P6000-HW6 WIRING

TO FAU CET
O R FLUS H VALVE

E323 1 68

MADE IN TH AILAND

C

US

UL

®

"Us e Co ppe r c ond ucto r o nly a nd
se e d eta ils  in ins tru ctioin  ma nua l"
"For  Gr oun din g Co ndu cto r, Use  18
AWG  min im um "

WA

R

N

IN

G

:

T

re

duc

e r

is

k

 of

 f

ir

e

 or

 el

ec

tr

ic

sh

oc

k

 -

 D

o

 n

o

t i

n

te

rc

on

nec

t

ou

tp

ut

 t

e

rm

in

at

io

ns

.

SENSOR AND
4 X 4 BOX

MOTOR

ACTUATOR

HW6

FIXTURE

BOX CLAMP

CABLE

ARMOR

FINISHED WALL

120 VAC/60Hz
Service

P6000-HW6

Содержание AquaSense AV ZEMS Series

Страница 1: ...llation and use the purchaser shall determine the suitability of the product for his intended use and the purchaser assumes all risk and liability whatever in connection therewith Where permitted by law the implied warranty of merchantability is expressly excluded If the products sold hereunder are consumer products the implied warranty of merchantability is limited to a period of three years and ...

Страница 2: ... Valve Rough In Model ZEMS6140 Model ZEMS6142 Model ZEMS6152 Models ZEMS6001 and ZEMS6003 SENSOR BOX FINISHED WALL 41 4 108 MAX 21 4 57 MIN 111 2 292 21 533 43 4 121 TOP OF FIXTURE 103 4 273 MAX 33 4 95 MIN AS SPECIFIED 21 533 141 2 368 43 4 121 1 I P S SUPPLY MOTOR ACTUATOR ...

Страница 3: ...with National Local codes and regulations All plumbing is to be installed in accordance with applicable codes and regulations Water supply lines must be sized to provide an adequate volume of water for each fixture Flush all water lines prior to making connections Sensor units should not be located across from each other or in close proximity to highly reflective surfaces Control Stop should never...

Страница 4: ...an operate as many as eight Automatic Sensor equipped Flushometers The Power Converter is supplied with a six foot cord If additional wire is needed from the Power Converter to the Flushometer s use 18 AWG for this by others Do not supply power to the Power Converter until installation of actuator sensor and Flushometer is completed and checked Proper polarity must be observed or damage to one or ...

Страница 5: ...pages 2 and 3 STEP 2 Mount Automatic Sensor Figure 3 Install the Zurn Automatic Sensor into the 2 gang electrical box using two 2 long screws provided Ensure that wires from sensor case point up for closet installs and point to the right for urinal installs The rubber push caps will be on the left side of the sensor for closet and at the top for urinal See Figures 4 and 4A The sensor lens faces ou...

Страница 6: ... will be sufficient 3 Insert the flush valve tailpiece B into the stop valve A and hand tighten the lock nut D to the stop valve Level the entire unit When all stops are connected to the water supply and water pressure is available flush the supply piping to remove dirt metal chips etc from system A A Before the valve is installed open each stop fully for a brief time and catch the water in a two ...

Страница 7: ... to the actuator pipe with setscrew toward actuator Do not tighten setscrew at this time 4 Pull actuator cable through hole with fish tape and back to sensor box Secure armored cable to box with box clamp 5 With escutcheon loose and handle port washer installed push cable into wall The actuator must be angled away from the valve body at this time until the actuator push rod clears the handle port ...

Страница 8: ...Flushometer simulating a user Adjust the control stop after each flush until the rate of flow delivered properly cleanses the fixture IMPORTANT NOTE Excessive water flow creates noise while too little flow will not satisfy the needs of the fixture Proper adjustment is made when 1 The plumbing fixture is cleansed after each flush without splashing water out from the lip 2 A quiet flushing cycle is ...

Страница 9: ...ure at supply 3 Consult fixture guide for minimum gallons per minute flow and running pressure for satisfactoryperformance 1 Damaged diaphragm 1 Install new P6000 ECA P6000 EUAreplacement kit 2 Enlarged by pass orifice 1 Install new P6000 ECA P6000 EUAreplacement kit 1 Enlarged by pass orifice 1 Install new P6000 ECA P6000 EUAreplacement kit 2 Urinal piston installed in closet 2 Replace urinal pis...

Страница 10: ...e Valve ZEMS6000 ZEMS6000 1 ZEMS6000 2 ZEMS6000 3 ZEMS6001 ZEMS6003 ZEMS6140 ZEMS6142 ZEMS6152 ZEMS6190 ZEMS6195 ZEMS6197 Install with flange against spud 14A 13 12A 15A 15B 15C 15D 15D 15E 16A C 16C 16A 16A 17 18 15F 15G 15G 18 18 19 18 17A 17B 17A ...

Страница 11: ...Vacuum Breaker Assembly 15B P6001 A AA CP Chrome Plated 1 1 4 X 8 1 2 Vacuum 20 P6000 K Tailpiece Coupling Assembly 21 P6000 C32 Locking Nut 22 P6000 C31 Tailpiece O Ring 23 P6000 C30 Snap Ring 24 Varies Tailpiece 25 Varies Adjustable Tailpiece Assembly 26 P6000 VC Cast Wall Escutcheon 27 P6000 YB CVR Supply Cover Tube Breaker Assembly 15C P6003 A AA CP Chrome Plated 3 4 X 8 1 2 Vacuum Breaker Ass...

Страница 12: ...OMMERCIAL BRASS OPERATION 5900 ELWIN BUCHANAN DRIVE SANFORD NC 27330 Phone 1 800 997 3876 Fax 919 775 3541 World Wide Web www zurn com In Canada ZURN INDUSTRIES LIMITED 3544 Nashua Drive Mississauga Ontario L4V1L2 Phone 905 405 8272 Fax 905 405 1292 ...

Отзывы: