Zte ZXR10 3228A Скачать руководство пользователя страница 29

C h a p t e r

5

Power Module

Table of Contents

Power Module Overview......................................................23
Active Power Supply ..........................................................23
Standby Power Supply .......................................................25
3228A-EI Monitoring Interface ............................................25
550w Power Supply Unit for ZXR10 3928A-PS ......................25

Power Module Overview

ZXR10 3900A/3200A series products provide built-in active power
supply. This active power supports -48V DC power and 220V AC
power. Additionally, ZXR10 3252A, ZXR10 3928A-FI and ZXR10
3952A also support 12V standby DC power supply input.

Active Power Supply

ZXR10 3900A/3200A series products provide built-in active power
supply. They adopt independent power supply. The power supply
input interfaces are located on back plane, supporting 48V DC and
220V AC.

The AC power supply board on ZXR10 3900A/3200A is shown in

Figure 29

.

F

IGURE

29 ZXR10 3900A/3200A AC P

OWER

I

NTERFACE

The DC power supply board on ZXR10 3900A/3200A is shown in

Figure 30

.

Confidential and Proprietary Information of ZTE CORPORATION

23

Содержание ZXR10 3228A

Страница 1: ...h Hardware Installation Manual Version 2 8 23 A ZTE CORPORATION ZTE Plaza Keji Road South Hi Tech Industrial Park Nanshan District Shenzhen P R China 518057 Tel 86 755 26771900 Fax 86 755 26770801 URL http ensupport zte com cn E mail support zte com cn ...

Страница 2: ...antability fitness for a particular purpose title or non in fringement ZTE CORPORATION and its licensors shall not be liable for damages resulting from the use of or reliance on the information contained herein ZTE CORPORATION or its licensors may have current or pending intellectual property rights or applications covering the subject matter of this document Except as expressly provided in any wr...

Страница 3: ...king Principles 9 Hardware Structure 10 ZXR10 3228A 10 ZXR10 3228A EI 11 ZXR10 3228A FI 12 ZXR10 3252A 12 ZXR10 3928A 13 ZXR10 3928A FI 14 ZXR10 3952A 14 ZXR10 3928A PS 15 Units Components Description 17 Control and Switching Board 17 Line Interface Card 20 FGEI 20 FGFI 21 FGFE 21 FBFE 22 Power Module 23 Power Module Overview 23 Active Power Supply 23 Standby Power Supply 25 3228A EI Monitoring In...

Страница 4: ...nstallation 33 Power on Procedure 34 RPS180 Backup Power 35 System Overview 35 Product Overview 35 Functions 35 Technical Features and Parameters 36 Structure and Principle 36 Working Principles 36 Hardware Structure 37 Boards 38 Power Conversion Board 38 CAPU 38 CDPU 38 LPDB 39 Installation and Debugging 39 Equipment Installation 39 Desktop Installation 39 Cabinet Installation 39 Cable Installati...

Страница 5: ...erequisite Skill and Knowledge To use the hardware installation manual effectively users should have a general understanding of OSI Model Familiarity with the following is helpful Protocols Routing concepts and Data Communication Terminologies What Is in This Manual The hardware installation manual contains the following chapters TABLE 1 CHAPTER SUMMARY Chapter Summary Chapter 1 Safety Instruction...

Страница 6: ...power module and fans Related Documentation The following documentation is related to this manual ZXR10 3900A 3200A V2 8 23 A Series Intelligent Routing Switch Hardware Manual ZXR10 3900A 3200A V2 8 23 A Series Intelligent Routing Switch User Manual Ethernet Volume ZXR10 3900A 3200A V2 8 23 A Series Intelligent Routing Switch User Manual Basic Configuration Volume ZXR10 3900A 3200A V2 8 23 A Serie...

Страница 7: ...njury or equipment damage Safety precautions introduced in this manual are supplementary to the local safety codes ZTE bears no responsibility in case of universal safety oper ation requirements violation and safety standards violation in designing manufacturing and equipment usage Safety Descriptions Contents deserving special attention during ZXR10 3900A 3200A configuration are explained in Tabl...

Страница 8: ...ZXR10 3900A 3200A Series Hardware Installation Manual This page is intentionally blank 2 Confidential and Proprietary Information of ZTE CORPORATION ...

Страница 9: ...p ported on data networks Thus higher requirements on network device quality and security should be met ZXR10 3900A 3200A provides abundant policies and resources for the Quality of Service QoS and ACL to ensure the QoS and system security ZXR10 3928A PS Ethernet switch in ZXR10 3900A 3200A supports PoE All of the 24 100Mpbs ports on this switch support PoE power supply PoE in CISCO standard and I...

Страница 10: ...is 2 VLAN Supporting VLAN based on port protocol and subnet Supporting IEEE 802 1Q allowing up to 4094 VLANs Supporting PVLAN Supporting SVLAN Supporting SuperVLAN 3 Layer 2 Protocols Supporting STP RSTP and MSTP Supporting static Trunk and LACP Supporting IGMP Snooping 4 Routing Protocols Supporting unicast routing protocols such as static route RIP v1 v2 OSPF IS IS BGP Supporting multicast routi...

Страница 11: ... Supporting 24 PoE ports with 15 4w output providing seamless connection to PoE CISCO IP telephone Cisco Aironet access point and camera and any terminal device meeting IEEE 802 3af standard Powerful and flexible management power supply setting with more details than IEEE standard Technical Features and Parameters ZXR10 3900A 3200A technical features and parameters are listed in Table 3 TABLE 3 ZX...

Страница 12: ...60Hz DC power supply 57V 40V Power consumption ZXR10 3228A 20w ZXR10 3228A FI 60w ZXR10 3228A EI 20W ZXR10 3252A 35w ZXR10 3928A 20w ZXR10 3928A PS 435w main control bord 65w MOP of PoE 370w ZXR10 3928A FI 60w ZXR10 3952A 35w Reliability MTBF 200000 hours MTTR 30 minutes Lightning protection 4KV Environment temperature Operating ambient temperature 50C to 450C Storage temperature 40 0C to 700C Env...

Страница 13: ...8G ZXR10 3928A FI 18 8G ZXR10 3952A 29 6G Packet forwarding rate ZXR10 3228A 13 98M ZXR10 3228A FI 13 98M ZXR10 3228A EI 13 98M ZXR10 3252A 22 02M ZXR10 3928A 13 98M ZXR10 3928A PS 13 98M ZXR10 3928A FI 13 98M ZXR10 3952A 22 02M Routing table entry ZXR10 3900A 3200A 12K MAC address table depth ZXR10 3900A 3200A 16K Confidential and Proprietary Information of ZTE CORPORATION 7 ...

Страница 14: ...ZXR10 3900A 3200A Series Hardware Installation Manual This page is intentionally blank 8 Confidential and Proprietary Information of ZTE CORPORATION ...

Страница 15: ...rol module It contains main processor and some other external functional chips and is used for system to process var ious applications It provides console port for data manipula tion and maintenance 2 Switching module the main part of switching module is packet processor used for processing and switching of packets sent from ports 3 Interface module It is composed of interface chips and pe riphera...

Страница 16: ...ical interfaces and 2 fixed gigabit Ethernet optical interfaces The electrical interface is RJ45 supporting twisted pairs of CAT 5 and above The optical interface is SFP supporting various gigabit optical modules meet ing SFP standard There is one slot on the front panel supporting four different interface cards The front panel of ZXR10 3228A is shown in Figure 2 FIGURE 2 ZXR10 3228A FRONT PANEL T...

Страница 17: ...s SFP supporting various gigabit optical modules meeting SFP standard There is one slot on the front panel supporting four different interface cards Additionally two RJ45 interfaces support 3 pair backbone node input and 5 pair of backbone node output The front panel of ZXR10 3228A EI is shown in Figure 5 FIGURE 5 ZXR10 3228A EI FRONT PANEL The back plane of AC power supply in ZXR10 3228A EI is sh...

Страница 18: ...RONT PANEL The back plane of AC power supply in ZXR10 3228A FI is shown in Figure 9 FIGURE 9 ZXR10 3228A FI BACK PLANE AC The back plane of DC power supply in ZXR10 3228A FI is shown in Figure 10 FIGURE 10 ZXR10 3228A FI BACK PLANE DC ZXR10 3252A The chassis height of ZXR10 3252A is 1U 1U 44 45mm ZXR10 3252A can support 48 100Mpbs Ethernet electrical interfaces and 4 fixed gigabit Ethernet optical...

Страница 19: ...abit Ethernet optical interfaces The electrical interface is RJ45 supporting twisted pairs of CAT 5 and above The optical interface is SFP supporting various gigabit modules meeting SFP standard The front panel of ZXR10 3928A is shown in Figure 14 FIGURE 14 ZXR10 3928A FRONT PANEL The back plane of AC power supply in ZXR10 3928A is shown in Figure 15 FIGURE 15 ZXR10 3928A BACK PLANE AC The back pl...

Страница 20: ... FIGURE 17 ZXR10 3928A FI FRONT PANEL The back plane of AC power supply in ZXR10 3928A FI is shown in Figure 18 FIGURE 18 ZXR10 3928A FI BACK PLANE AC The back plane of DC power supply in ZXR10 3928A FI is shown in Figure 19 FIGURE 19 ZXR10 3928A FI BACK PLANE DC ZXR10 3952A The chassis height of ZXR10 3952A is 1U 1U 44 45mm ZXR10 3952A can support 48 100Mpbs Ethernet electrical interfaces and 4 f...

Страница 21: ... 24 100Mpbs Ethernet electrical interfaces and 2 fixed gigabit Ethernet optical interfaces The electrical interface is RJ45 supporting twisted pairs of CAT 5 and above PoE in CISCO standard and IEEE 802 3af standard The optical interface is SFP supporting various gigabit and 100Mpbs modules meeting SFP standard The front panel of ZXR10 3928A PS is shown in Figure 23 FIGURE 23 ZXR10 3928A PS FRONT ...

Страница 22: ...ZXR10 3900A 3200A Series Hardware Installation Manual This page is intentionally blank 16 Confidential and Proprietary Information of ZTE CORPORATION ...

Страница 23: ... through Console port The console port is the RJ45 socket which is connected to the COM port on the background management terminal through a serial cable One end RJ45 connector of the serial cable is connected to ZXR10 3900A 3200A and the other end DB9 female connector is connected to the background management terminal Management Port Management terminal operates and maintains ZXR10 3900A 3200A th...

Страница 24: ...on The system power supply works well Off The system power supply is faulty LINK ACT Flash Packets are being transmitted or received on the interface On A link is established on the interface Off There is no connection between this interface and others SPEED On The port speed is 100Mbps 100M port the port speed is 2 5Gbps Gigabit port Off The port speed is 10Mbps 100M port the port speed is 1Gbps ...

Страница 25: ...ash link ACT Yellow flash link ACT Double color Indicator on Electrical Interface POE Mode No con nection or disable Green power supply Yellow Non PD Check fails Green 1G con nection Yellow 2 5G con nection Rate Mode No con nection Green flash link ACT Yellow flash link ACT Green full duplex Yellow half duplex Duplex Mode No con nection Green flash link ACT Yellow flash link ACT Double color Indic...

Страница 26: ...Flash board works well 1HZ Perma nently on when AC works well AC PWR None Flash Power alarm DC RPS None Perma nently on when DC works well Mas ter Slave M S Slave Green Master Line Interface Card FGEI There are two Gigabit Ethernet uplink electrical interfaces in SF 2800 2GE 2RJ45 mode on FGEI sub card as shown in Figure 25 FIGURE 25 SF 2800 2GE 2RJ45 SUB CARDFGEI 20 Confidential and Proprietary I...

Страница 27: ...the link works well the indicator is on When data are sent or received the indicator flashes FGFE There are one Gigabit Ethernet uplink optical interfaces and one Gi gabit Ethernet uplink electrical interface in SF 2800 2GE SFPRJ45 mode on FGFE sub card as shown in Figure 27 FIGURE 27 SF 2800 2GE SFPRJ45 SUB CARDFGFE There are three indicators on FGFE panel The gigabit optical in terface contains ...

Страница 28: ...on FBFE sub card as shown in Figure 28 FIGURE 28 RS 2800 2FE 2SFP SUB CARD There are two indicators on FBFE panel ACT1 and ACT2 They correspond to two 100Mbps electrical interfaces When the link works well the indicator is on When data are sent and received the indicator flashes 22 Confidential and Proprietary Information of ZTE CORPORATION ...

Страница 29: ...lly ZXR10 3252A ZXR10 3928A FI and ZXR10 3952A also support 12V standby DC power supply input Active Power Supply ZXR10 3900A 3200A series products provide built in active power supply They adopt independent power supply The power supply input interfaces are located on back plane supporting 48V DC and 220V AC The AC power supply board on ZXR10 3900A 3200A is shown in Figure 29 FIGURE 29 ZXR10 3900...

Страница 30: ...tted Voltage Range 57V 40V Input Current 1 5A Max Power Consumption 37W 2 AC ZXR10 3900A 3200A supports the same AC power supply ex cept for ZXR10 3228A The parameters are described as fol lows Input Voltage single phase 90VAC 264VAC Input Current 1 5A Frequency 47Hz 63Hz Max Power Consumption 100W Line Voltage Waveform Deviation Factor WDF 5 The AC power supply parameters of ZXR10 3228A are de sc...

Страница 31: ...100W 3228A EI Monitoring Interface There are two RJ45 interfaces on ZXR10 3228A EI The right inter face serves for 1 pair backbone node output and 3 pair backbone node input The left interface serves for 4 pair backbone node output as shown in Figure 32 FIGURE 32 ZXR10 3228A EI MONITORING INTERFACE 550w Power Supply Unit for ZXR10 3928A PS The active power supply on ZXR10 3928A PS is swappable 550...

Страница 32: ... AC power parameters on 3928A PS are described as follows 1 Input Voltage single phase 100VAC 240VAC 90 264Vac 2 Input Current Max 7 2A 3 Frequency 43Hz 67Hz 4 Max Power Consumption 647W 5 Line Voltage Waveform Deviation Factor WDF 5 26 Confidential and Proprietary Information of ZTE CORPORATION ...

Страница 33: ...s cabinet is to be used you need refer to the 19 Inch Stan dard Cabinet Installation Manual for cabinet installation Desktop Installation Install four plastic bottom blocks plastic bottom blocks are strews are provided together with device on the bottom plate of switch to form an air passage for which heat generated by power module can be dissipated efficiently For the installation method refer to...

Страница 34: ...ccessories as shown in Figure 35 FIGURE 35 INSTALLING THE FLANGES 1 Case 2 Flange 3 Screw Install two symmetrical brackets at the two sides of the 19 inch cabinet to support the switch as shown in Figure 36 FIGURE 36 INSTALLING THE BRACKETS 1 Bracket 2 Rack 3 Screw After the installation push in the switch along the bracket and fix the flanges to the cabinet as shown in Figure 37 28 Confidential a...

Страница 35: ...ables based on the power modules 1 AC power cable installation The AC power cable adopts the standard printer power cable as shown in Figure 38 FIGURE 38 AC POWER CABLE One end of the AC power cable is connected to the AC power socket of ZXR10 3900A 3200A AC power module and the other end is connected to the 220 VAC power socket 2 DC power cable installation i DC 48V power cable C PWR 084 is shown...

Страница 36: ... socket Connect two terminals on end B according to labels pasted on each con ductor The B1 is connected to 48VGND of DC power sup ply and B2 is connected to 48V The conductor labels on end B are described in Table 8 TABLE 8 LABEL End B1 End B2 48VGND 48V ii DC standby power C PWR 072 is shown in Figure 40 FIGURE 40 DC STANDBY POWER C PWR 072 The correspondence between two ends of DC cables are sh...

Страница 37: ... cables are basic cables in ZXR10 3900A 3200A configuration which are used to configure and maintain ZXR10 3900A 3200A Serial console cables are delivered together with ZXR10 3900A 3200A with one end to be DB9 console port connected to serial port of PC and the other end to be RJ45 port connected to Console port on MP Board of ZXR10 3900A 3200A Serial console cables is shown in Figure 41 FIGURE 41...

Страница 38: ...und cable FIGURE 42 NETWORK CABLE STRUCTURE DIAGRAM Cables can be classified into the following two types according to different cable crimping order in the plug Straight through network cable RJ45 the cable connection re lationship is in the one to one correspondence at both ends The specific connection relationship is shown in Table 11 TABLE 11 STRAIGHT THROUGH NETWORK CABLE RJ45 CABLE SEQUENCE ...

Страница 39: ... TX RX on the panel Do not mix them There are two kinds of fibers single mode fiber and multi mode fibers Users can use them according to practical conditions Six fibers are shown in Table 13 TABLE 13 FIBER TYPES Mode Switch Connector End Connector Type FC PC SC PC Single Mode SC PC square adapter ST PC FC PC SC PC Multi mode SC PC square adapter ST P As for fiber out of the cabinet make sure to p...

Страница 40: ...of temperature and humidity refer to those measured at 2 m above the floor and 0 4 m in front of the device the measurement is done with no protective board in the front or at the back of the cabinet 2 The short term working condition means a continuous running period of not more than 48 hours and accumulated running periods a year of no more than 15 days 2 Check whether the power cables and the c...

Страница 41: ...200A series products The height and width of the standby power supply box are 1U and 19 inch respectively Thus it can be configured on the 19 inch rack together with ZXR10 3900A 3200A switches to provide them with needed standby 12V power input Functions ZXR10 RPS180 can be configured on the 19 inch rack together with ZXR10 3900A 3200A switches to provide them with needed standby 12V power input 1...

Страница 42: ...r supply 100V 240V50Hz 60Hz DC power supply 57V 40V Power consumption Full Configuration Consumption 220W Reliability MTBF 1000000h Lightning protection 4KV Environment temperature Operating ambient temperature 0 45 Storage temperature 40 70 Environment humidity Relative humidity 10 to 90 non condensing Structure and Principle Working Principles ZXR10 RPS180 is a multi purpose 12V output redundanc...

Страница 43: ...RE 43 ZXR10 RPS180 AC MODEL SYSTEM DIAGRAM ZXR10 RPS180 DC model system diagram is shown in Figure 44 FIGURE 44 ZXR10 RPS180 DC MODEL SYSTEM DIAGRAM Hardware Structure The chassis height of ZXR10 RPS180 is 1U 1U 44 45mm It adopts standard 19 inch box which can be installed outside sep arately or within the standard cabinet It contains two cards power supply card and power distribu tion card It pro...

Страница 44: ...C power CAPU CAPU is used to convert inputted AC power to the needed 12V DC power 1 Standard three core input socket is used 2 The wide voltage range supports 100V 240V input voltage en vironment 3 It has high power factor and PFC modulation to reduce interface to electric network CDPU CDPU is used to convert inputted 48V to the needed 12V DC power 1 Standard three core DC input socket is used 2 T...

Страница 45: ... is to be used you need refer to the 19 Inch Stan dard Cabinet Installation Manual for cabinet installation Desktop Installation Install four plastic bottom blocks plastic bottom blocks are strews are provided together with device on the bottom plate of switch to form an air passage for which heat generated by power module can be dissipated efficiently Cabinet Installation To install the ZXR10 RPS...

Страница 46: ...48V power cable C PWR 084 is shown in Figure 48 FIGURE 48 DC CABLE C PWR 084 The correspondence between two ends of DC cables are shown in Table 16 TABLE 16 DC CABLES TWO ENDS CORRESPONDENCE End A End B Power Signal 1 B1 48VGND 2 B2 48V The end A is connected to 48V input socket Connect two terminals on end B according to labels pasted on each con ductor The B1 is connected to 48VGND of DC power s...

Страница 47: ...eeve to anode of external 12V power source Power on Procedure Check the equipment room environment and hardware installation before powering on ZXR10 RPS180 1 Check whether the equipment room temperature humidity and voltage meet the installation requirements as shown in Table 19 TABLE 19 TEMPERATURE AND HUMIDITY Temperature RH Item Long Term Working Condition Note 1 Short Term Working Condition N...

Страница 48: ... of no more than 15 days 2 Check whether the power cables and the cables are connected correctly and reliably or not 3 Check other hardware 4 Power on ZXR10 RPS180 in the following steps i Turn on the external power supply ii Turn on the power switch on the back plane of switch 5 Power off procedure is shown as follows i Turn off the power switch on the back plane of switch ii Turn off the externa...

Страница 49: ...Plane DC 14 Figure 17 ZXR10 3928A FI FRONT PANEL 14 Figure 18 ZXR10 3928A FI Back Plane AC 14 Figure 19 ZXR10 3928A FI Back Plane DC 14 Figure 20 ZXR10 3952A FRONT PANEL 15 Figure 21 ZXR10 3952A Back Plane AC 15 Figure 22 ZXR10 3952A Back Plane DC 15 Figure 23 ZXR10 3928A PS FRONT PANEL 15 Figure 24 ZXR10 3928A PS Back Plane 15 Figure 25 SF 2800 2GE 2RJ45 Sub cardFGEI 20 Figure 26 SF 2800 2GE 2SFP...

Страница 50: ...Power C PWR 072 30 Figure 41 ZXR10 3900A 3200A Serial Console Cable Structure Diagram 31 Figure 42 Network Cable Structure Diagram 32 Figure 43 ZXR10 RPS180 AC Model System Diagram 37 Figure 44 ZXR10 RPS180 DC Model System Diagram 37 Figure 45 ZXR10 RPS180 Front Panel 38 Figure 46 ZXR10 RPS180 Backplane 38 Figure 47 AC POWER CABLE 40 Figure 48 DC cable C PWR 084 40 Figure 49 DC Standby Power Suppl...

Страница 51: ...respondence 30 Table 8 Label 30 Table 9 Two Ends Correspondence of DC Cables 31 Table 10 Serial Console Cable Sequence 31 Table 11 Straight through Network Cable RJ45 Cable Sequence 32 Table 12 Crossover network cable RJ45J Cable Sequence 33 Table 13 Fiber Types 33 Table 14 TEMPERATURE AND HUMIDITY 34 Table 15 ZXR10 RPS180 TECHNICAL FEATURES AND PARAMETERS 36 Table 16 DC cables Two Ends Correspond...

Отзывы: