Chapter 4 Service Configuration
Parameter Description
Parameter
Description
<
1-16
>
MD index.
<
1-32
>
MA index.
<
1-8191
>
MEP ID, unique within an MA.
Example
The following example stops an ongoing one-LM detection:
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 1 one-lm send-packet stop
4.42.10 cfm two-dm send-packet
Purpose
This command starts bidirectional DM detection.
Command Mode
Global configuration mode
Syntax
cfm md-session
<
1-16
>
ma-session
<
1-32
>
mep-id
<
1-8191
>
two-dm send-packet
[
contin
ue-time
<
60-600
>
interval
<
1-60
>]
Parameter Description
Parameter
Description
<
1-16
>
MD index.
<
1-32
>
MA index.
<
1-8191
>
MEP ID, unique within an MA.
<
60-600
>
Duration of bidirectional DM detection. The default value is 60
seconds.
<
1-60
>
Packet sending interval of bidirectional DM detection. The default
value is 1 second.
Example
The following example starts bidirectional DM detection at the default detection intervals:
zte(cfg)#cfm md-session 1 ma-session 1 mep-id 1 two-dm send-packet
4-571
SJ-20130731155059-003|2013-11-27 (R1.0)
ZTE Proprietary and Confidential