![Zte ZXR10 2900E Series Скачать руководство пользователя страница 551](http://html1.mh-extra.com/html/zte/zxr10-2900e-series/zxr10-2900e-series_command-reference-manual_941699551.webp)
Chapter 4 Service Configuration
Default
The link monitoring function is disabled.
Example
The following example enables the link monitoring function on port 1:
zte(cfg)#set ethernet-oam port 1 link-monitor enable
4.30.8 set ethernet-oam port link-monitor symbol-period
Purpose
This command sets the symbol period event of link monitoring.
Command Mode
Global configuration mode
Syntax
set ethernet-oam port
<
portlist
>
link-monitor symbol-period threshold
<
1-65535
>
wind
ow
<
1-65535
>
Parameter Description
Parameter
Description
<
portlist
>
Port list.
threshold
<
1-65535
>
Number of incorrect symbols collected in a unit period.
window
<
1-65535
>
Period of symbol amounts. The unit is millions. For example, 30
means that a period is every 30 millions symbols are collected.
Guidelines
The symbol period is determined by the number of symbols collected by the switch within
a specified time period. That is, when a certain number of symbols is collected, a period
is finished. A link alarm event occurs if the number of the collected incorrect symbols
exceeds the threshold value ruled by the period.
Default
The number of incorrect symbols collected in a unit period is 1.
The period of symbol numbers is 1.
The period of symbol numbers
The following example sets the number of the incorrect symbols collected in a unit time to
1 and the symbol period to 30:
4-491
SJ-20130731155059-003|2013-11-27 (R1.0)
ZTE Proprietary and Confidential