ZXG10 OB06 ZTE Integrated Outdoor GSM Base Station Technical Manual
70
Confidential and Proprietary Information of ZTE CORPORATION
The alarm reporting process is shown in Figure 61.
F
I G U R E
6 1
A
L A R M
R
E P O R T I N G
P
R O C E S S
BSC
AEM/PA alarm
Backbone
node alarm
CMM software
FUC software
CHP software
CIP software
The CIP software collects the alarms of itself and the fan/AEM/PA alarms,
and then reports them to the FUC software. while the CHP software
collects the alarms of itself and reports them to the FUC software. The FUC
software reports the collected alarms and its own alarms to the CMM
software. The alarms of the backbone nodes are collected by the CMM
software, which reports all alarms of this site to BSC through LapD, and
implements some relevant alarm processing, such as power amplification
shut-down.
Online Software Loading
It supports the OB06 software online loading by the BSC.
The software loading process is shown in Figure 62.
F
I G U R E
6 2
S
O F T W A R E
L
O A D I N G
P
R O C E S S
CMM software
FUC software
CHP software
CIP software