ZXG10 OB06 ZTE Integrated Outdoor GSM Base Station Technical Manual
18
Confidential and Proprietary Information of ZTE CORPORATION
Power subrack
Batteries (4): 75 kg
Bearing capacity of a single concrete platform: >800 kg
Power Supply
Power Supply Range of Power Supply
System
Input voltage: 88 VAC~300 VAC, optional.
Power Consumption Indexes
The maximal power consumption of each module is as follows:
TRM (×6): 200 W per TRM
CMM (2 pieces): 15 W per CMM;
AEM (×6): 15 W per AEM
Internal mixed-flow fan (×3): 40 W per fan
Internal axial flow fan (×3): 20 W per fan
Fan for HEX: 60 W
Transmission: 100 W
Battery charging: 1500 W
Heater: 2500 W
Maintenance socket: 500 W
When fully configured, the power consumption of the whole system is <
6511W.
Ambient Conditions
Requirements for Grounding and Lightning
Protection
OB06 outdoor BTS features a lightning-protection capability of B+C level.
Содержание ZXG10 OB06
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 10: ......
Страница 88: ...74 Confidential and Proprietary Information of ZTE CORPORATION ...
Страница 104: ...90 Confidential and Proprietary Information of ZTE CORPORATION This page is intentionally blank ...
Страница 108: ...94 Confidential and Proprietary Information of ZTE CORPORATION This page is intentionally blank ...