35
T8/T8-2 settings
BACK
00012V40-GB-W
AR
TUNG FREIARM-FLACHBETTMASCHINEN_-_2022-09-27 - DC
Manual main shaft positioning
The starting point for this operation is the
Test machine attachment
(f head)
menu, which is still active.
• Unlock the main shaft brake by pressing the
Jog
key once.
Ö
The main shaft can now be freely rotated.
• Manually rotate the main shaft with the handwheel or supplied lever wrench to a more
exact position within the stated tolerance.
Ö
The current main shaft position is directly displayed on the
Main shaft position
button.
• Once the desired main shaft position is reached, press the
Jog
button again to apply the
main shaft brake.
• Adjust the height of the borer.
Once the borer height has been set, pressing [R8]
Stop testing
returns
the main shaft to its original position. The machine also performs a
needle change to the needle that was active beforehand.