4.2.4 LOGOUT 

Click the “Logout”  bottom and pop-up “Confirmation” 
dialog;  select  “Yes”  or  “No”,  choose  “Yes”  to  exit  the 
current page and “No” to return to the user login interface 
again. 

 

 
 

 

 

 

Содержание 90 -980 Series

Страница 1: ...HD PTZ Video Camera User Manual PTZ HDMI SDI Camera PTZ NDI HX Camera Printed in China ...

Страница 2: ...formance 5 2 3 2 Network Performance 5 2 4 FAST INSTALLTION 5 2 4 1 Bracket Mount 5 2 4 2 Video Output 7 2 5 INTERFACE INSTRUCTION 7 2 5 1 External Interface 7 2 5 2 Bottom Dial Switch 7 2 5 3 RS 232 Interface 7 2 5 4 Power on Initial Configuration 8 3 APPLICATION INSTRUCTION 9 3 1 REMOTE CONTROLLER 9 3 2 MENU SETTING 11 3 2 1 MAIN MENU 11 3 2 2 SETUP Setting 11 3 2 3 CAMERA Setting 11 3 2 4 P T Z...

Страница 3: ...rom the AC outlet 2 Please clean the camera cover by soft cloth or tissue to avoid scratches 3 Do not clean the camera lens by strong or corrosive cleanser to avoid scratches and impact on image effects 1 3 CERITIFICATION This equipment has been tested and found to comply with the limits of the European Council Directive on the approximation of the member states relating to electromagnetic compati...

Страница 4: ...and network interfaces LAN or NDI Model NO 90XYZ 980 X Color Y Network Interface 8 LAN 9 NDI Z Optical Zoom 1 12x 2 20x 3 30x Please refer to corresponding features in this manual 2 2 2 Dimension Figure 2 1 2 Camera dimension 2 2 3 Camera Interface Explanation Figure 2 2 3 Interface of PTZ Series 1 Camera Lens 2 Camera Base 3 Remote Controller Receiver Light 4 Bottom Dial Switch 5 Tripod Screw Hol...

Страница 5: ... quiet and moves smoothly and very quickly to designated position 6 Multi Format Video Outputs support HDMI 3G SDI and LAN interfaces The 3G SDI is available for 100m transmission at 1080p60 format 7 Leading Auto Focus Technology Leading auto focus algorithm makes lens a fast accurate and stable auto focusing 8 Low power Sleep Function Support low power sleep wake up the consumption is lower than ...

Страница 6: ...6 2 Upside down mounting ...

Страница 7: ...ection refers to No 10 in Figure 2 2 3 b Connect the camera and the monitor by 3G SDI video cable video output is available after camera self check 2 5 INTERFACE INSTRUCTION 2 5 1 External Interface External interface of this device VISCA interface RS485 Input 3G SDI Output HDMI Output Network Output Interface DC 12V Power Supply and Audio Input Interface Figure 2 5 1 PTZ model external interface ...

Страница 8: ...tom left it returns to the HOME position both horizontal and vertical are in the middle position Then lens zooms in and out self check is finished IR led will also stop flashing If the preset 0 is set camera will rotate to the preset 0 position after self check Note If you set preset 0 when Power on self check is completed the camera automatically moves to the preset 0 position NO Port Definition ...

Страница 9: ...eck again and back to HOME position Note If power on mode is turned on and Preset 0 is set it will automatically point to the specified preset position when there is no operation within 12s 2 Camera Address Selection Select the camera address to control 3 Number Key Set or run 0 9 presets Press a number key 0 9 directly to run a relative preset Note Action in vain if a relative preset position is ...

Страница 10: ...nning stops as soon as the key is released 9 BLC Control Key Back Light ON OFF Turn on or off the back light 10 Menu Setting Enter exit the OSD menu or return to the previous menu 11 Camera IR Remote Control Address Setting F1 Camera Address No 1 F2 Camera Address No 2 F3 Camera Address No 3 F4 Camera Address No 4 12 Key Combination Functions 1 Clear all presets 2 6 Restore factory defaults 3 9 Fl...

Страница 11: ...1 Baudrate 2400 4800 9600 115200 3 2 3 CAMERA Setting Move the cursor to the Camera in the Main Menu click the HOME key to enter into the Camera setting page as shown Exposure Enter into exposure setting Color Enter into color setting Image Enter into image setting Focus Enter into focus setting Noise Reduction Enter into noise reduction setting Style Remain Default 1 EXPOSURE Setting Move the cur...

Страница 12: ...ss 0 15 Flip H ON OFF Flip V ON OFF B W Mode color black white Gamma default 0 47 0 50 0 52 0 55 DZoom digital zoom options ON OFF DCI Dynamic Contrast OFF 1 8 4 FOCUS Setting Move the cursor to the Focus in the Menu click the HOME key to enter into the Focus setting page as shown Focus Mode Auto manual AF Zone Up middle down AF Sensitivity High middle low 5 NOISE REDUCTION Move the cursor to the ...

Страница 13: ... version information Camera Version Display camera version information AF Version Display the focus version information Note Picture above is for reference only different models of cameras have different versions 3 2 7 RESTORE DEFAULT Setting Move the cursor to the Restore Default in the Main Menu click the HOME and enter into the Restore Default setting page as shown Restore default YES and NO op...

Страница 14: ...e window of Ethernet Properties then Double click the Internet Protocol Version 4 TCP IPv4 as picture below to enter into Properties window of Internet Protocol Version 4 TCP IPv4 2 Secondly select options as picture below Type in the IP address subnet mask and Default gateway found in the DOS command window Use default gateway as Preferred DNS server address and 8 8 8 8 as Alternate DNS server 3 ...

Страница 15: ...position run delete and other operations 1 Login as administrator Both Username and Password are admin PTZ control can be carried out zoom focus video capture sound zoom full screen and set the preset position run and delete you can preview set configuration and logout 2 Login as normal user Both Username and Password are user1 or user2 PTZ control can be carried out zoom focus video capture sound...

Страница 16: ... control set rate control mode save and reboot to take it effect Main Sub stream default CBR VBR optional Image Quality Set the image quality image quality can be changed only when rate control is variable bit rate Main stream default best Sub stream default better best better good bad worse worst optional Bit Rate Kb s Set the video bit rate Main stream 4096 default 64 12288 optional Sub stream d...

Страница 17: ...re or brightness priority default 4 0 15 optional DRC Set the dynamic range default 4 OFF 8 optional c Color WB Mode RG Turning BG Turning Sat uration Hue and AWB Sensitivity can be set WB Mode Set the white balance mode default Auto Manual OnePush and VAR optional RG Turning Set the red gain default 0 10 to 10 optional BG Turning Set the Blue gain default 0 10 to 10 optional Saturation Set the sa...

Страница 18: ...20P60 720P50 720P30 720P25 1080P59 94 1080I59 94 720P59 94 720I59 94 1080P29 97 and 720P29 97 optional Note Click the Save button to display the Save the parameters successful message then settings take effect 3 Network Configuration 1 Network Port Port Data Set the data port the device will restart automatically after changed default 3000 0 65535 optional Port Web Set Web port the device will res...

Страница 19: ...0000001 Register Name IPC Register Password 12345678 Equipment Belong Users can add their own Administrative Regions Users can add their own Alarm Areas Users can add their own Device Address Users can add their own Local SIP Port 5060 Range 0 65535 Server IP IP address of the computer Server SIP Port 5060 Range 0 65535 Server ID 34020000002000000001 Note Click on the Save button it will be valid ...

Страница 20: ... Set a password Select User Administrator default admin select a common user1 default user1 to select a common user 2 default user2 user can modify their own Confirm Password Confirm the input passwords are the same or not Note Click the Save button to display the Save the parameters successfully message then settings take effect Note Please note the case sensitivity of the username and password I...

Страница 21: ...21 4 2 4 LOGOUT Click the Logout bottom and pop up Confirmation dialog select Yes or No choose Yes to exit the current page and No to return to the user login interface again ...

Страница 22: ... Run and then type cmd in the computer Click OK then turn on DOS command window to enter ping 192 168 5 163 Press the Enter key to appear message as follows Description network connection is normal 7 Instruction for using NDI a Network interface for normal device is LAN port and for NDI model is NDI port b There is no other difference between PTZ model and NDI model except for the network interfac...

Страница 23: ... Post More Live Video after then select Use Stream Key and paste them into RTMP S address setting section of encoder 13 Push stream through RTSP VLC a First choose NETWORK for VLC media source After login into the camera s web interface go to Configuration Stream Publish And then choose RTSP for Protocol Type and use Host Address and Stream Name to create a unique network URL for VLC Last and clic...