3.

Use the screws removed in step 1 to fasten the SIB-01. 

The SIB-01 works only in the MRS-1044 if the system is Version
1.2 and later. If your MRS-1044 is Version 1.0, you must update
your system as described on the next page. 

NOTE

Correct

Incorrect

Installing

the

SIB-01

Updating the MRS-1044 to Version 1.2

In order to use the SIB-01, the MRS-1044 system must be updated to
Version 1.2. Perform this update using the "Version Update" CD-ROM
supplied with the SIB-01. 

• To perform the update, a SCSI compatible CD-R/CD-RW drive or CD-

ROM drive is required. If you do not have a suitable drive, please
consult your dealer or contact ZOOM Corporation. 

• The SIB-01 comes with two CD-ROMs: a "Version Update Disc"

(green label) for updating the system and a "Recovery Disc" (red label)
for restoring the hard disk of the MRS-1044 to the factory default
condition. Be careful not to mix up these discs. 

If you use the "Recovery Disc" and perform the steps described
below, all user projects will be deleted. 

1.

Connect the SCSI connector on the MRS-1044 (with SIB-01
installed) to the SCSI connector of the CD-R/CD-RW (CD-
ROM) drive, using a SCSI cable. 

Before performing this step, make sure that power to both components
is turned off. For details regarding the SCSI connection, refer to page
8. 

2.

Turn power to the CD-R/CD-RW (CD-ROM) drive on, insert the
"Version Update Disc" (green label), and then turn power to
the MRS-1044 on. 

Green label

Red label

Version Update Disc

Only updates the 
system.

Projects created by 
user are retained. 

Recovery Disc

Caution 

!

Restores hard disk to factory default 
condition. System will be Version 1.2.

All projects created by 
user will be deleted. 

NOTE

5

ZOOM SIB-01

4

ZOOM SIB-01

Содержание SIB-01

Страница 1: ...y Precautions 2 Installing the SIB 01 3 Updating the MRS 1044 to Version 1 2 5 MRS 1044 Version 1 2 Features 7 Connection of External SCSI Devices 8 Compatible drives 8 Connection of SCSI Devices 8 Cr...

Страница 2: ...rranty Never attempt to modify this product in any way Any damage or malfunction arising from modification attempts is not covered by the warranty Malfunction If there is any malfunction or other sign...

Страница 3: ...ating the system and a Recovery Disc red label for restoring the hard disk of the MRS 1044 to the factory default condition Be careful not to mix up these discs If you use the Recovery Disc and perfor...

Страница 4: ...o mix up these discs NOTE Ver Up Done Ver Up Sure NOTE Ver Up to 1 20 Updating the MRS 1044 to Version 1 2 MRS 1044 Version 1 2 Features This section describes additional features of the MRS 1044 whic...

Страница 5: ...es Hard disk No Yes No Backup restore Create audio CD Backup restore over multiple media volumes Connection of External SCSI Devices Connection of External SCSI Devices drive using a SCSI cable The SC...

Страница 6: ...ry CD player After it has been finalized no more data can be added to a CD R CD RW disc The waveform data of V takes 10 of tracks 9 10 are recorded as is on the audio CD Note that fader EQ effects and...

Страница 7: ...ear the MRS 1044 has not properly recognized the CD R CD RW drive Check the power on off condition of the drive and the SCSI connection 5 Use the cursor E R keys to make the display indicate CD R RW B...

Страница 8: ...inserted 2 In the main screen press the PROJECT UTILITY key 3 Use the cursor E R keys to make the display indicate UTILITY CD R RW and then press the ENTER key If the above menu does not appear the MR...

Страница 9: ...ne of the cursor W Q keys is pressed only the indication STOP PLAYER is shown and the key press is ignored 8 To return to the main screen press the EXIT key several times NOTE NOTE Creating an Audio C...

Страница 10: ...key several times CdrwErs NORMAL Creating an Audio CD 5 Press the ENTER key The display now shows the indication FINALIZ SURE 6 To carry out the finalizing process press the ENTER key once more The fi...

Страница 11: ...VE FireZone NOTE ZOOM SIB 01 Storing a Project on External Media Project Backup You can store any project on an external SCSI device for backup The following types of SCSI devices can be used CD R CD...

Страница 12: ...xt CD R CD RW disc appears 10 When the above message appears insert a new CD R CD RW disc and press the ENTER key CHANGE DISC002 DISC001 wait Disc number NOTE Storing a Project on External Media Proje...

Страница 13: ...Storing a Project on External Media Project Backup The backup operation resumes The new disc number and the indication wait appear on the display To cancel the operation press the EXIT key to bring u...

Страница 14: ...LOAD FireZone Project name Project number Reading a Stored Project from External Media Project Restore You can read any project that was stored on an external SCSI device back into the hard disk of th...

Страница 15: ...fferent correct restore will not be possible To change the restore source disc press the EXIT key and repeat the procedure from step 4 NOTE 25 LOAD FireZone LOAD ExtDRV LOAD InsDisk1 NOTE Reading a St...

Страница 16: ...ndication changes to LOAD COMPLETE 7 To return to the main screen press the EXIT key several times 25 LOAD FireZone NOTE Reading a Stored Project from External Media Project Restore 6 Turn the dial to...

Страница 17: ...ected to the MRS 1044 2 When using a MO drive or ZIP drive make sure that the correct disc is inserted 3 In the main screen press the PROJECT UTILITY key 4 Use the cursor E R keys to make the display...

Страница 18: ...xternal Storage Device The MRS 1044 can format a connected hard disk or media in a connected ZIP or MO drive This is required before using ZIP or MO media or a hard disk for the first time When format...

Страница 19: ...k the entire V take is shifted to the front 10 To return to the main screen press the EXIT key several times NOTE New start point New end point Selected V take Changing the Length of a V take Trimming...

Страница 20: ...ice operation check the following points first MRS 1044 does not recognize SCSI device Check whether SIB 01 is correctly installed Check whether MRS 1044 system has been upgraded to version 1 2 Check...

Страница 21: ...ZOOM CORPORATION NOAH Bldg 2 10 2 Miyanishi cho Fuchu shi Tokyo 183 0022 Japan PHONE 81 42 369 7116 FAX 81 42 369 7115 Web Site http www zoom co jp Printed in Japan SIB 01 5000 1...

Отзывы: