Configuration 

Configuration of the ZSI-320 is done using Meyertech’s Windows based configuration tool Mpower 

Config Version 

This entry screen shows information relating to the firmware installed in the ZSI-320 
 

 

 

Config structure 

The version number of the configuration data format within the attached ZSI-320. – see Mpower manual for 
more details. 

(stored) 

The version number of the configuration data format stored on the PC. – see Mpower manual for more 
details.

 

Software 

The version number of the ZSI-320’s firmware 

Status 

Z

S

I

-

3

2

0

The status of the communications – see Mpower manual for more details

 

 
 
 

 

MEYERTECH LIMITED

 

 

Содержание ZSI-320

Страница 1: ...ZSI 320 User Manual Issue 03 Page 1 of 20 USER MANUAL ZSI 320 ZSI 320 CCTV ISDN Controller Issue 03 ZSI 320 MEYERTECH LIMITED...

Страница 2: ...on 3 What is a ZSI 320 3 Operation 4 Configuration 8 Config Version 8 PC1 Port 9 PC2 MMT Port 10 PC3 Clear Port 11 ZVM Port 12 Telephone 12 Site 14 Operation 15 Diagnostics 16 Support 17 Maintenance 1...

Страница 3: ...ch s Site Controller family a unit can under alarm conditions automatically contact a remote control room or can be part of a seamless dial on demand service The features described in this manual refe...

Страница 4: ...ZSI 320 User Manual Issue 03 Page 4 of 20 Operation ZSI 3 20 MEYERTECH LIMITED...

Страница 5: ...ZSI 320 User Manual Issue 03 Page 5 of 20 ZSI 320 MEYERTECH LIMITED...

Страница 6: ...ZSI 320 User Manual Issue 03 Page 6 of 20 MEYERTECH LIMITED ZSI 320...

Страница 7: ...ZSI 320 User Manual Issue 03 Page 7 of 20 Installation See ZSI 320 Installation Guide available from Meyertech Technical Support MEYERTECH LIMITED ZSI 320...

Страница 8: ...e installed in the ZSI 320 Config structure The version number of the configuration data format within the attached ZSI 320 see Mpower manual for more details stored The version number of the configur...

Страница 9: ...ZSI 320 User Manual Issue 03 Page 9 of 20 PC1 Port Key Internal use only MUST NOT BE MODIFIED Baud Rate Internal use only MUST NOT BE MODIFIED MEYERTECH LIMITED ZSI 320...

Страница 10: ...this to take effect Default MMTAUDIOECHOON The following options may be used Audio MMTAUDIOLINEINVOLn Sets line input volume to n MMTAUDIOLINEOUTVOLn Sets line output volume to n MMTAUDIOECHOON Switch...

Страница 11: ...SI 320 User Manual Issue 03 Page 11 of 20 PC3 Clear Port site The site number associated with the ZSI 320s location Default 1 Baud Rate Internal use only MUST NOT BE MODIFIED MEYERTECH LIMITED ZSI 320...

Страница 12: ...indicate that the unit should expect to be polled If On the unit will wait for a poll before transmitting any information on this port Default On Controller ZSI 320 To indicate that the unit is to ma...

Страница 13: ...site number of the remote dialup site Default 0 Tel Number 1 The first ISDN number for the site Default blank Tel Number 2 The second ISDN number for the site This number is optional and a single chan...

Страница 14: ...automatically relinquished if a remote operator does not move it This timeout is only applied to control from remote sites Default 60 seconds Max Redial Time When an outgoing call is un answered the u...

Страница 15: ...the box is ticked all messages are forwarded on to the site controller to handle If set to Off the unit will resolve all switching and telemetry issues itself It will use the matrix output number def...

Страница 16: ...mms settings 5 InitialisePC3Port Re initialise PC3 port Required after changes to comms settings or AC video phone mode 6 InitialiseZvmPort Re initialise Zvm port Required after changes to comms setti...

Страница 17: ...res no Planned Preventive Maintenance periods PPM s as it is mainly solid state in design The ZSI 320 contains no serviceable parts and should be returned to our Service Centre in Scunthorpe for repai...

Страница 18: ...ge or we can dispose of the product free of charge Meyertech Service Centre Unit 4E Queensway Business Centre Dunlop Way Scunthorpe DN16 3RN Tel 01724 278833 Fax 01724 289099 Disposal There are no add...

Страница 19: ...ch defects arise in parts materials or equipment which have not been manufactured or designed by the Seller but have been purchased at the Buyer s request by the Seller from the Buyer s designer and m...

Страница 20: ...rect by patch or new release at its option that part of the software which does not so comply provided that such non compliance has not been caused by any modification variation or addition to the sof...

Отзывы: