background image

Symbols

9650-0308-01 Rev. A

ZOLL AED Plus Service Manual

v

Symbols

Symbols used in this manual or on the equipment include the following:

Class II equipment

Defibrillation-protected Type BF patient connection

ATTENTION:

 Refer to the operator’s guide for more information

WARNING:

 Dangerous voltage

New battery cells

Not new battery cells

Push button

Do not push button

   VARTA

Recommended manufacturer

Do not use this manufacturer

Unit equipped to treat adult and pediatric patients

Conformité Européenne

 Complies with medical device directive 93/42/EEC.

Содержание Aed Plus

Страница 1: ...Service Manual 9650 0308 01 Rev A March 2005...

Страница 2: ...l product information updates are available ZOLL and stat padz are registered trademarks and AED Plus AED Pro CPR D padz pedi padz pro padz PowerCharger Preconnect RescueNet Smart Alarms and v pak are...

Страница 3: ...g a Unit for Service vii Chapter 1 Maintenance Tests Preparations for Testing 1 2 Test Equipment 1 2 1 0 Physical Inspection 1 3 2 0 Preventive Maintenance Test 1 4 3 0 Manual Self Test 1 9 Chapter 2...

Страница 4: ...TABLE OF CONTENTS ii www zoll com 9650 0308 01 Rev A...

Страница 5: ...ew this section thoroughly before servicing an AED Plus unit Chapter 1 Maintenance Tests Provides the recommended procedures for evaluating the condition and performance of the AED Plus unit Chapter 2...

Страница 6: ...or Operator s Guide 9651 0800 01 Describes the AED Plus simulator which you can use to test the AED Plus unit s response to various simulated cardiac rhythms Conventions This manual uses uppercase ita...

Страница 7: ...tected Type BF patient connection ATTENTION Refer to the operator s guide for more information WARNING Dangerous voltage New battery cells Not new battery cells Push button Do not push button VARTA Re...

Страница 8: ...ed by ZOLL Discard used batteries properly Do not recharge disassemble or dispose of batteries in fire Batteries might explode if mistreated This device is protected against interference from radio fr...

Страница 9: ...t to the ZOLL Technical Service Department for repair obtain a service request SR number from the service representative Remove all batteries from the unit Pack the unit in its original container or e...

Страница 10: ...PREFACE viii www zoll com 9650 0308 01 Rev A...

Страница 11: ...h of which requires a pass fail rating For each step perform the specified action and then verify that the expected results occur If all expected results occur assign a Pass rating to the step otherwi...

Страница 12: ...tional ZOLL AED Plus Simulator When connected to an AED Plus unit the simulator can send it various simulated cardiac rhythms ventricular fibrillation normal sinus rhythm or asystole and optional simu...

Страница 13: ...ne Test Procedure Observe the following Pass Fail 1 1 Is the unit clean 1 2 Are all signs of wear reasonable and not excessive 1 3 Are the top panel and housing undamaged and free of cracks 1 4 Are in...

Страница 14: ...on the analyzer and set its function to VF ventricular fibrillation Variations in Messages When verifying messages in the test results please be aware of the following issues The wording of some messa...

Страница 15: ...D DON T TOUCH PATIENT PRESS TREATMENT BUTTON or PRESS SHOCK BUTTON 2 2 Press the Treatment button first shock Analyzer indicates a defibrillator discharge at the configured first shock energy level 12...

Страница 16: ...TMENT ADVISED or SHOCK ADVISED DON T TOUCH PATIENT PRESS TREATMENT BUTTON or PRESS SHOCK BUTTON 2 4 Press the Treatment button third shock Analyzer indicates a defibrillator discharge at the configure...

Страница 17: ...ghtly no more than 1 inch or 2 cm and continue to do so If the unit has a display prevent the bar on the chest compression gauge from extending into the area between the lower two lines Unit emits spa...

Страница 18: ...L FOR HELP These three prompts are optional OPEN AIRWAY CHECK BREATHING GIVE TWO BREATHS CHECK CIRCULATION or CHECK PULSE PLUG IN CABLE 2 9 Check the expiration date on the previously connected defibr...

Страница 19: ...and compression depth sensor are functional when CPR D padz are attached Audio output circuitry is functional Display screen if present is functional Tools Needed None Test Setup Turn off the AED Plus...

Страница 20: ...CHAPTER 1 MAINTENANCE TESTS 1 10 www zoll com 9650 0308 01 Rev A...

Страница 21: ...unit This chapter also lists critical AED Plus error log messages that indicate the unit requires technical service This chapter contains the following sections Troubleshooting the AED Plus Unit on p...

Страница 22: ...ned off Verify that the electrode cable is properly plugged into the patient cable connector Turn the unit off and then press and hold the ON OFF button for at least 5 seconds to perform a self test V...

Страница 23: ...ELEASE TREATMENT BUTTON Release the Treatment button Do not press the button until the charge ready tone sounds and the button begins flashing If the message persists remove the unit from service and...

Страница 24: ...age COMMUNICATIONS ESTABLISHED refer to the ZAS help for instructions on saving the unit s history file and viewing the included error log Table 2 2 AED Plus Error Log Messages Error No Error Message...

Страница 25: ...curred when calling a Nucleus operation 21 An unexpected error has occurred when calling a Rhapsody operation 22 An unexpected coding error has occurred 23 No Language installed corrupt language 24 Th...

Страница 26: ...CHAPTER 2 TROUBLESHOOTING 2 6 www zoll com 9650 0308 01 Rev A...

Страница 27: ...appendix provides a sample maintenance checklist for the AED Plus unit To ensure that the equipment is functioning properly and ready for emergency use complete the checklist periodically according t...

Страница 28: ...structions To maintain records for maintenance testing photocopy the checklist shown on the following pages The checklist includes an entry for each test described in this manual Use these copies to r...

Страница 29: ...e tests and keep it for your records For a description of each numbered test refer to Chapter 1 Maintenance Tests in the AED Plus Service Manual Serial No Location Date Tester Signature Result of Chec...

Страница 30: ...A 4 www zoll com 9650 0308 01 Rev A...

Страница 31: ...analyzer 1 2 1 4 Documentation iv E Error log 2 4 H History file device 2 4 I Impulse 4000 analyzer 1 2 1 4 Inspection physical 1 3 IrDA port 1 2 L Log error 2 4 M Maintenance tests 1 1 checklists A...

Страница 32: ...ations vi Self test manual 1 9 Service technical vii Simulator iv 1 2 Software ZOLL Administration 1 2 2 4 T Technical Service vii Tests maintenance 1 1 checklist A 1 prerequisites 1 2 Troubleshooting...

Отзывы: