26
2.5 Parameter Setting
2.5.1 Specific Operations on Setting Parameters
4
)
By using
&
, user can change the
corresponding value of the parameter
5
)
By pressing
, user can make the parameters return to the initial value.
6
)
By pressing
, user can save the changed content and turn off the Sewing LED. After
that, the machine returns to parameter number selection status.
7
)
Pressing
will end the parameter setting mode and let system return to ordinary status.
2.5.2 Example for Setting Parameters
1
.
Setting of Max Sewing Speed
Emp.: Set the upper limitation of sewing speed to 1800rpm
1
)
When Sewing LED is off, user can press
to set the parameters.
(
After user presses
, the displayed
1.30 means that the Max speed of the
No.1 parameter is 3000rpm
。)
2
)
User can use
&
to change the
number of parameter.
3
)
By pressing
, user can adjust the wanted
parameter number and turn on the Sewing LED
1
)
When the Sewing LED is off, user can press
to display the content of Parameter No.1.
Parameter No.1 displays the Max speed of
sewing machine.
2
)
When the No.1 parameter is displayed; user can
press
to turn on the Sewing LED.
Then the content of No.1 parameter is displayed
in the screen.