background image

2

© Copyright 2020 Zoeller

®

 Co. All rights reserved.

The Zoeller Engineered Products warrants its X71 Series of submersible 

pumps to the original owner to be free from defects in workmanship and 

materials under the following conditions and limitations by the owner 

paying the applicable percentage of the list price of the following parts 

in effect at time of replacement in the specified *installations.  

Conditions

1. Approval of installation and start up of the equipment by the Zoeller 

Authorized Factory Representative.

2.  Removal, reinstallation and transportation charges shall be borne by 

the buyer.

3.  Labor charges for warranty repair shall not be assumed by the company 

for repairs made after one year from date of installation. Returns must 

have prior  authorization from the company.

4. Hazardous Location Series pumps must be returned to Zoeller.

5. Controls and accessories warranty (See specific warranty below).

Standard warranty shall be 18 months from date of manufacture, 12 

months from date of installation or 12 months from the date of start 

up with a start up report on file with Zoeller. 

Each Zoeller X71 Series Pump installation is required to have a completed Zoeller Engineered Products Start-up Report (ZM1074). The report is to be completed 

by an approved Start-up Technician in the presence of the installing contractor. A copy of this report will be on file at the Zoeller Engineered Products offices in 

Louisville, KY.  

Failure to comply with the requirement will void the following warranty agreement.

 Refer to page 7 for pumps that are kept in short term storage.

Limited Warranty 

*MUNICIPAL SEWAGE PERMANENT INSTALLATION

Five Year (10,000 hr) Months After Shipment - Limited Warranty

MONTHS            0-18            19-30            30-45            46-60

HOURS             0-3,000      3,000-5,000     5,000-7,500     7,500-10,000
Rotor & Stator     0%              30%              50%               80%

Mechanical Seal    

0%              30%              50%              

75%

Impeller           0%              30%              50%               80%

Cutter Assy.         0%              30%              50%              80% 

Ball Bearings      0%              50%              80%              100%

Pump Housing       

0%              30%              50%             

100%
Controls and accessories included for 18 months.

Recommended Limits of a Grinder Pump Application

These recommended application limits are for pump stations pumping to a gravity main. For applications where a lift station would handle more 

than 60 homes, a solids handling type pump should be considered.

*Zoeller Company does not recommend a simplex station on anything over two homes in order to maintain continuous service during unusual conditions.

 

Simplex Station 

Duplex Station

 

Model 

HP  Homes GPD  Homes  GPD

 

X7110 High Head 

2* 

800 

20 

8,000

 

X7111 High Head 

2* 

800 

25 

10,000

 

X7112 High Head 

7.5 

2* 

800 

30 

12,000

 

X7110 Reversing 

2* 

800 

30 

18,000

 

X7111 Reversing 

2* 

800 

38 

15,000

 

X7112 Reversing 

7.5 

2* 

800 

45 

18,000

 

X7110 High Flow 

2* 

800 

40 

16,000

 

X7111 High Flow 

2* 

800 

50 

20,000

 

X7112 High Flow 

7.5 

2* 

800 

60 

24,000

Limitations

but not limited to hydrocarbons, hydrocarbon derivatives (oil, gasoline, 

solvents, etc.) or other abrasive or corrosive substances, is in lieu of all 

other warranties expressed or implied.

Contact authorized service station to obtain any needed repair 

replacement parts.  For additional information pertaining to our 

warranty or if service cannot be obtained locally, contact Zoeller 

Engineered Products, 3649 Cane Run Road, Louisville, Kentucky 40211-

1961,  Attn:  Customer Service.

ZOELLER ENGINEERED PRODUCTS EXPRESSLY DISCLAIMS LIABILITY FOR 

SPECIAL, CONSEQUENTIAL, OR INCIDENTAL DAMAGES OR BREACH OR 

EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY OF 

FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY SHALL 

BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.

Some states do not allow limitation on the duration of an implied 

warranty, so the above limitation may not apply to you.  Some states 

do not allow the exclusion or limitation of incidental or consequential 

damages, so the above limitation or exclusion may not apply to you.

This warranty gives you specific legal rights, and you may also have 

other rights which vary from state to state.
Zoeller Engineered Products neither assumes nor authorizes any 

person or company to assume for it any other obligation in connection 

with  the  sale  of  its  equipment.    Any  enlargement  or  modification  of 

this warranty by any other party is their sole responsibility.  No other 

warranties expressed or implied, including implied warranties of 

merchantability and fitness for a particular purpose will apply.

Zoeller Engineered Products’ sole obligation under all the above 

warranties shall be to make repairs and to replace parts when 

necessary on products that have been returned to Zoeller Engineered 

Products or an authorized service facility and found to be defective 

by the company.  Part(s) that fail and that inspection determines to 

be defective in material or workmanship, will be repaired, replaced, 

or remanufactured at Zoeller Engineered Product’s option provided, 

however, that by so doing we shall not be obligated to replace an 

entire assembly, the entire mechanism, or the complete unit.  Major 

components and controls not manufactured by the company are 

covered by the original manufacturer warranty in lieu of this warranty.  

This warranty shall not apply to any product or part of a product, 

including pumps, controls, lifting devices, basins, and power cables 

which are damaged or subject to misuse, accident, neglect, operated 

outside the limits of the pump curves, used in a manner contrary to 

the printed instruction, or damaged due to a defective power supply, 

improper electrical protection, or faulty installation or repair.
The company will not be responsible for travel expenses, rented 

equipment, outside contractor fees, or unauthorized repair shop 

expenses.  No allowance will be made for shipping charges, damages, 

labor or other charges that may occur due to product failure, repair, or 

replacement.
This warranty does not apply to any material that has been 

disassembled without prior approval of Zoeller Engineered Products, 

subjected to misuse, misapplication, neglect, alternation, accident 

or act of God; that has not been installed in accordance with Zoeller 

Engineered Products installation instructions; that has been exposed to 

In instances where property damages are incurred as a result of an alleged product failure, the property 

owner must retain possession of the product for investigation purpose.  

Содержание X71 Series

Страница 1: ...1 Limited Warranty 2 Preinstallation Information 3 Electrical Data 3 Typical Sewage Installation 4 Pump Wiring Instructions 5 6 Operation 7 Maintenance 7 Service Checklist 8 Safety Instructions TO AVOID SERIOUS OR FATAL PERSONAL INJURY OR MAJOR PROPERTY DAMAGE READ AND FOLLOW ALL SAFETY INSTRUCTIONS IN THIS MANUAL AND ON THE PUMP THIS MANUAL IS INTENDED TO ASSIST IN THE INSTALLATION AND OPERATION ...

Страница 2: ...ment parts For additional information pertaining to our warranty or if service cannot be obtained locally contact Zoeller Engineered Products 3649 Cane Run Road Louisville Kentucky 40211 1961 Attn Customer Service ZOELLER ENGINEERED PRODUCTS EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OR EXPRESSED OR IMPLIED WARRANTY AND ANY IMPLIED WARRANTY OF FITNESS F...

Страница 3: ...in in detail the requirements for the installation and wiring of electrical equipment in hazardous locations 1 Not for use in acidic atmospheres 2 Do not lift carry or hang pump by the electrical cables Damage to the electrical cables can cause shock burns or death 3 Make sure there is a properly grounded connection available All pumps are furnished with provisions for proper grounding to help pro...

Страница 4: ...ble electrical and plumbing codes including but not limitedto NationalElectricalCode local regional and or state plumbing codes etc ZEPA0560 1 Electrical wiring and protection must be in accordance with the National Electrical Code per NEC articles 500 through 503 for installation in Class I Division 1 Group C D Class I Zone 1 Groups IIA IIB locations and any other applicable state and local elect...

Страница 5: ...rcuit in the seal cavity where 2 seal leak probes are housed An indicator light will activate whenever water is present in the cavity Whenever the seal leak light is activated indicating that the lower seal has failed the pump should be removed and serviced in order to avoid damage to the motor 3 The green wire shall be connected to a ground lug in the panel CONTROL PANELS These pumps require a co...

Страница 6: ...a control panel with level control is required Follow the instructions provided with the panel to wire the system Before installing a pump check the pump rotation to insure that wiring has been connected properly to power source and that the green lead of power cord See wiring diagram is connected to a valid ground Momentarily energize the pump observing the directions of kick back due to starting...

Страница 7: ...sired location of each float function Valves Dischargevalvesshouldbeplacedinthefullyopenposition Systems shouldnotbeoperatedforextendedperiodsoftimewiththedischarge valves partially closed due to damaging the valve SHUTDOWN PROCEDURES If a system is shutdown for more than six months the following is recommended Pumps If pit is to remain dry then the pump can remain in the pit With the pumpinthepit...

Страница 8: ...in head and or capacity after a period or use Increase Pipe Friction Clogged line or check valve Abrasive material chemical deteriorated impeller and pump housing If the above check list does not uncover the problem consult the factory Do not attempt to service or otherwise disassemble pump Service Checklist Trouble Shooting Steps Check Voltage At If No Voltage If Voltage No 1 Line terminals in pu...