background image

3

© Copyright 2014 Zoeller Co. All rights reserved.

SERVICE PARTS

QWIK JON

®

 ULTIMa 202

202-a 

No plug

STaNDaRD

202-a 

g-plug

STaNDaRD

202-a 

g-plug (white)

STaNDaRD

202-a 

 E/f plug

STaNDaRD

202-a 

 E/f plug

pREMIUM

202-a 

 E/f plug

STaNDaRD

202-a 

g-plug 

STaNDaRD

12 /10 

to

Current

3/12 

to

Current

1 /11 

to

Current

9 /11 

to

Current

3/12 

to

Current

3/12 

to

Current

7/12 

to

Current

Item

Description

part No.

1

Qwik Jon® Ultima Sewage Removal System

202-1001

202-1005

202-1002

202-1003

202-1010

202-1006

202-1012

2

Replacement pump with discharge pipe

150872

151965

151965

151895

152167

151966

152296

3

Tank cover with discharge fittings

017373

017373

017373

017373

017373

017373

017373

4

Tank

018500

018500

018500

018500

018500

018500

018500

5

Seal

017350

017350

017350

017350

017350

017350

017350

6

Rubber coupling with hose clamps

151563

151563

151563

151563

151563

151563

151563

7

Extension kit for behind the wall install. (optional)

10-3050

10-3050

10-3050

10-3050

10-3050

10-3050

10-3050

3

1

2

4

6

5

7

SK2838

Содержание QWIK JON ULTIMA 202

Страница 1: ...1 28 or 1 6 gallons per flush 5 All fixtures connecting to the system must be on the same floor level 1 To reduce the risk of electrical shock a properly grounded receptacle or control box must be in...

Страница 2: ...ABILITY SHALLBELIMITEDTOTHEDURATIONOFTHEEXPRESSEDWARRANTY Some jurisdictions do not allow limitations on the duration of an implied warranty so the above limitation may not apply to you Some jurisdict...

Страница 3: ...on Ultima Sewage Removal System 202 1001 202 1005 202 1002 202 1003 202 1010 202 1006 202 1012 2 Replacement pump with discharge pipe 150872 151965 151965 151895 152167 151966 152296 3 Tank cover with...

Страница 4: ...ow or incorrect voltage Have a qualified electrician check house wiring Damaged Impeller Contact a Zoeller Service Station Incorrect float adjustment Contact Product Support Department Pump is air loc...

Страница 5: ...er sharp objects do not puncture the pump unit Level the pump unit to within 3 mm 1 8 using hydraulic cement or similar material SK2589 STEP 3 ROUGH IN 1 Position the pump unit a minimum of 3 mm 1 8 f...

Страница 6: ...out using a 44 mm 1 hole saw This is to ensure there is no leakage problems from inlets not in use When utilizing side inlets install a check valve on the incoming line SK2591 DRILL POINT 1 1 2 SLIP I...

Страница 7: ...m 220 DN25 1 pipe max 149 m 489 DN20 pipe max 119 m 390 DN25 1 pipe max 218 m 715 DN20 pipe max 171 m 561 2 m 6 5 4 m 13 50 Hz 60 Hz 1 5 m 5 3 m 10 4 m 13 5 m 15 1 DN25 1 PIPE MAX 146m 479 DN20 3 4 P...

Страница 8: ...Member States relating to Pump Conforms to Machinery Directive 2006 42 EC Standards used EN 809 1998 Electromagnetic Compatibility 2004 108 EC Standards used EN 61000 3 2 EN 61000 3 3 and EN 55014 1...