QWIK JON

®

 ULTIMA 202 SYSTEM

INSTALLATION INSTRUCTIONS

PREINSTALLATION CHECKLIST

NOTICE TO INSTALLER:  Instructions must remain with installation.

SECTION:  W2.50.025

FM2369_Ec

0214

Supersedes

1213

  1.  Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using. 

DO NOT

 remove the 

test plugs from the pump.

  2.  Carefully read all the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for 

future reference.

SEE BELOW FOR LIST OF NOTES

NOTES

REfER TO WaRRaNTy ON pagE 2.

SEE BELOW FOR LIST OF WARNINGS

CAUTION

SEE BELOW FOR LIST OF CAUTIONS

Patent No. 7,203,976
Other Patents Pending

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347 USA

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961 USA

+1 (502) 778-2731 • FAX +1 (502) 774-3624

®

Your Peace of Mind is Our Top Priority

 

®

visit our web site:

www.zoeller.com

50/60Hz

  1.  The Qwik Jon

®

 Ultima is fitted with a specially-designed grinder pump 

and is capable of pumping fecal matter, toilet paper and sanitary articles 

which may be  accidentally dropped into the toilet.  It is not recommended 

to flush such foreign objects as they might clog the sanitary sewer.

  2.  Check to be sure your power source is adequate to handle the amperage 

requirements of the motor as indicated on the pump or unit I.D. tag. 

  3.  All plumbing (discharge and vent lines) must be installed to meet governing 

codes. 

Unit must be vented. Do not use an automatic plumbing 

vent device.

  4.  Maximum operating temperature must not exceed 54°C (130°F). 
  5.  Do not use cleaning products containing bleach in the toilet tank, toilet or 

attached fixtures as they will degrade the pump seals.

  1.  Repair and service should be performed by an Authorized Service Station 

only (consult factory).

 2. Recommended for installations with total dynamic head up to 6 m (20') for 

60 Hz or  5 m (15') for 50 Hz. Consult factory if 50 Hz installation is above 

5 m (15') vertical height in DN25 (1") pipe or if 60 Hz installation is above 

4 m (13') vertical height. Mini-Grinder Pump is designed for use in Qwik 

Jon

®

 Ultima units only. It is not designed for use in any other application.

  3.  Pumps with the “UL” mark and/or the “US” mark are tested to UL Standard 

UL778. CSA Certified pumps are certified to CSA Standard C22.2 No. 

108. Qwik Jon

®

 Ultima units only. It is not designed for use in any other 

application.

  4.  Model 202 toilet utilizes 4.8 or 6.1 liters (1.28 or 1.6 gallons) per flush.
  5.  All fixtures connecting to the system must be on the same floor level.

 1. 

To reduce the risk of electrical shock, a properly grounded receptacle or 

control box must be installed in accordance with the governing codes.  Never 

remove ground pin from plug.

 

 2.  Make certain that the ground fault interrupter protected receptacle or control 

box is within the reach  of the pump’s power supply cord.  DO NOT USE AN 

EXTENSION CORD. Extension cords that are too long or too light do not 

deliver sufficient voltage to the pump motor, and they could present a safety 

hazard if the insulation were to become damaged or the connection end were 

to fall into a damp or wet area.

 3.  Make sure the pump's electrical supply circuit is equipped with fuses or circuit 

breakers of proper capacity.  A separate branch circuit is recommended, sized 

according to the governing electrical codes for the current shown on the pump 

name plate.

 4.  

Testing for ground.

   As a safety measure, each electrical outlet should be 

checked for ground using an Underwriters Laboratory Listed circuit analyzer 

which will indicate if the power, neutral and ground wires are correctly connected 

to your outlet.  If they are not, call a qualified licensed electrician.

 5.  FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS 

POWER SOURCE BEFORE HANDLING.  If pump is wired direct, de-energize 

the circuit at the control box.  DO NOT, UNDER ANY CIRCUMSTANCES, 

REMOVE THE GROUND PIN.  Wear insulated protective shoes and do not 

stand in water.  Certain plug types may include a 3-prong ground plug to help 

protect against electrical shock.  A properly grounded 3-prong receptacle or 

control box must be installed in accordance with governing codes.  

  6.  Installation and servicing of the pump's electrical circuits and hardware should 

only be performed by a qualified licensed electrician.

 7.  Installation and maintenance of this appliance is not intended for persons 

(including children) with reduced physical, sensory or mental capabilities, or 

lack of experience or knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for their 

safety.

 8. 

Risk of electrical shock.

  Do not remove power supply cord and strain relief 

or connect conduit directly to the pump.  If the supply cable is damaged, it 

must be replaced by an authorized Zoeller Representative.

 9.  Pump contains oil which becomes pressurized and hot when operating.  Allow 

2½ hours after disconnecting before attempting service.

 10. Pump is not intended for potable water due to possible contamination by oil 

contained in the pump.

 11. 

Risk of electric shock.

  These pumps have not been investigated for use in 

swimming pools and marine areas.

DaTE INSTaLLED:

MODEL NUMBER:

© Copyright 2014 Zoeller Co. All rights reserved.

Содержание QWIK JON ULTIMA 202

Страница 1: ...1 28 or 1 6 gallons per flush 5 All fixtures connecting to the system must be on the same floor level 1 To reduce the risk of electrical shock a properly grounded receptacle or control box must be in...

Страница 2: ...ABILITY SHALLBELIMITEDTOTHEDURATIONOFTHEEXPRESSEDWARRANTY Some jurisdictions do not allow limitations on the duration of an implied warranty so the above limitation may not apply to you Some jurisdict...

Страница 3: ...on Ultima Sewage Removal System 202 1001 202 1005 202 1002 202 1003 202 1010 202 1006 202 1012 2 Replacement pump with discharge pipe 150872 151965 151965 151895 152167 151966 152296 3 Tank cover with...

Страница 4: ...ow or incorrect voltage Have a qualified electrician check house wiring Damaged Impeller Contact a Zoeller Service Station Incorrect float adjustment Contact Product Support Department Pump is air loc...

Страница 5: ...er sharp objects do not puncture the pump unit Level the pump unit to within 3 mm 1 8 using hydraulic cement or similar material SK2589 STEP 3 ROUGH IN 1 Position the pump unit a minimum of 3 mm 1 8 f...

Страница 6: ...out using a 44 mm 1 hole saw This is to ensure there is no leakage problems from inlets not in use When utilizing side inlets install a check valve on the incoming line SK2591 DRILL POINT 1 1 2 SLIP I...

Страница 7: ...m 220 DN25 1 pipe max 149 m 489 DN20 pipe max 119 m 390 DN25 1 pipe max 218 m 715 DN20 pipe max 171 m 561 2 m 6 5 4 m 13 50 Hz 60 Hz 1 5 m 5 3 m 10 4 m 13 5 m 15 1 DN25 1 PIPE MAX 146m 479 DN20 3 4 P...

Страница 8: ...Member States relating to Pump Conforms to Machinery Directive 2006 42 EC Standards used EN 809 1998 Electromagnetic Compatibility 2004 108 EC Standards used EN 61000 3 2 EN 61000 3 3 and EN 55014 1...

Отзывы: