CARBON MONOXIDE DETECTORS

Whether you have a Aquanot

®

 Backup Pump System, or a competitive brand, all use batteries that give off gaseous by-products when charging. Some of 

these by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely activate. In order to help prevent false 

activation, Zoeller Company recommends moving the battery as far apart from the CO detector as possible or, if necessary, vent the battery to the exterior. 

Zoeller Company provides the previous statements only as guidelines to help prevent false activation of the CO detector. In no way are they meant to supersede 

the instructions that accompany the detector nor do they supersede advice from the CO detector manufacturer.

If the audible alarm associated with your CO detector is activated, we recommend the following actions:

1)  Take immediate action for personal safety as recommended in the CO detector literature.

2)  Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses natural gas.

3)  If you are certain that no CO is being produced, then a charging battery may be producing gaseous by-products which are causing the CO detector to 

activate. Contact the manufacturer and ask for recommendations as to what can be done to prevent the alarm activation.

MAIL TO:

  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:

  3649 Cane Run Road • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

Your Peace of Mind is Our Top Priority

 

®

®

visit our web site:

www.zoeller.com

There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality.  A defective battery will never become fully 

charged and may damage the charging circuits of the  Control. It is for this reason that Zoeller offers its own line of batteries.  We offer both a Water/Acid 

Deep-Cycle Battery and maintenance-free AGM battery which can run the pump continuously for over 7½ hours.  These times are based on continuous 

pumping at 8' (2.4 mm) of static head. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battery.

Follow these recommendations:

•  Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger

•  Do NOT use a “maintenance-free” battery unless it is an AGM battery

•  Replace your battery every 3 years

•  Do not let corrosion build up on the battery terminals

•  To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only)

•  Use of included plastic battery box is recommended to keep battery safe and clean. 

PROTECT YOUR WARRANTY:  

•  Water level in batteries must be checked once a month (wet cell batteries only)

THE AQUANOT

®

 

BATTERY

© Copyright 2016 Zoeller

®

 Co. All rights reserved.

DECLARATION OF CONFORMITY

Zoeller Pump Company declares under our sole responsibility that the Aquanot Model 508 to which this declaration relates, is in conformity with the Council Directives 

on the approximation of the laws of the EC Member States relating to:
• 

Electrical equipment designated for use with certain voltage limits (Directive 2006/95/EC), standards used: EN 60335-1:2004+A1+A11+A12+A2+A13+A14

+A15 and EN 60335-2-29:2004+A2

• 

Electromagnetic Compatibility (Directive 2004/108/EC), standards used: EN 55014-1:2006+A2:2011, EN 55014-2:2015, EN 61000-3-2:2014, EN 61000-3-3:2013

• 

Restrictive and Hazardous Substances RoHS (Directive 2011/65/EU), standards used: EN 50581-2012

• 

Waste Electrical and Electronic Equipment WEEE (Directive 2012/19/EU)

Содержание AquaNot 508 Series

Страница 1: ...ontrol system plugs directly into the 115V 230V outlet DO NOT USE AN EXTENSION CORD 2 Make sure the 115V 230V electrical supply circuit is equipped with fuses or circuit breakers of proper capacity 3 DC emergency pumps are designed for handling clear water Do not use in septic tanks to pump effluent or sewage pits to pump sewage 4 Repair and service of your DC backup system should be performed by ...

Страница 2: ... and lower the water to the normal operating level and shut off b The yellow charging light should be on The charger is replacing the energy consumed during the test The green light will come on after the charger has replaced the energy consumed during the test 3 Adddistilledwatertobatterywhennecessaryperbatterymanufacturer s instructions CAUTION Battery acid is dangerous Take proper safety precau...

Страница 3: ...er precaution must be taken when handling Battery box will accomodate a maximum battery size of 13 342 mm Length x 7 178 mm Width x 9 241 mm Height BATTERY SELECTION The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure The DC pump electronic controls and all the parts required for installation are included except the batter...

Страница 4: ...rimary sump pump and the control box should be on separate circuits 17 Reconnect power to primary sump pump 18 Optional A dongle may be used to input a name and number into the charger for service information to the end user 19 Optional On the bottom of the charger there is a pair of dry contacts to signal an auxiliary device of a low battery high water and reverse polarity alarm condition This si...

Страница 5: ...VEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP FIG 1 DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX DC CHARGER OUTLET CHARGER R R BATTERY BOX OUTLET PRIMARY PUMP DC PUMP INSTALLED IN LINE WITH COLUMN PUMP IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP 1 MIN OUTLET CHARGER DC CHARGER R R SK2959 SK2960 25 4 MM 25 4 MM ...

Страница 6: ...RGE TEE REDUCER FITTING CLAMP CHECK VALVE ASSEMBLY CLAMP BATTERY BOX 12 VOLT MARINE BATTERY SUPPLIED BY USER FIG 3 CLAMP WHITE LEAD TO POSITIVE BLACK LEAD TO DC PUMP WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE TO FLOAT WHITE LEAD 30 AMP FUSE DC CONTROL BOX BLACK LEAD TO NEGATIVE TO FLOAT SWITCH GREEN LEAD SPLICER FLOAT SWITCH DC PUMP ...

Страница 7: ...screen shows current alarms The cycle counter screen shows how many times the DC float has been activated The AC power loss counter screen shows how many times the AC power has been removed from the charger Optional a screen may also show the name and number of a service provider The 6 LED lights also display information about the charger at a glance The red AC power light will be on if AC power i...

Страница 8: ...arantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of the Control It is for this reason that Zoeller offers its own line of batteries We offer both a Water Acid Deep Cycle Battery and maintenance free AGM battery which can run the pump continuously for over 7 hours These times are based on continuous pumping at 8 2 4 mm of static hea...

Отзывы: