CARBON MONOXIDE DETECTORS
Whether you have a Aquanot
®
Backup Pump System, or a competitive brand, all use batteries that give off gaseous by-products when charging. Some of
these by-products can produce a rotten egg odor. Also, some of these by-products can cause a CO detector to falsely activate. In order to help prevent false
activation, Zoeller Company recommends moving the battery as far apart from the CO detector as possible or, if necessary, vent the battery to the exterior.
Zoeller Company provides the previous statements only as guidelines to help prevent false activation of the CO detector. In no way are they meant to supersede
the instructions that accompany the detector nor do they supersede advice from the CO detector manufacturer.
If the audible alarm associated with your CO detector is activated, we recommend the following actions:
1) Take immediate action for personal safety as recommended in the CO detector literature.
2) Contact the appropriate agency to determine if the CO is being produced by your furnace, water heater, or any other device which uses natural gas.
3) If you are certain that no CO is being produced, then a charging battery may be producing gaseous by-products which are causing the CO detector to
activate. Contact the manufacturer and ask for recommendations as to what can be done to prevent the alarm activation.
MAIL TO:
P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO:
3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624
Your Peace of Mind is Our Top Priority
®
®
visit our web site:
www.zoeller.com
There are millions of batteries manufactured each year, so it is impossible to guarantee consistent quality. A defective battery will never become fully
charged and may damage the charging circuits of the Control. It is for this reason that Zoeller offers its own line of batteries. We offer both a Water/Acid
Deep-Cycle Battery and maintenance-free AGM battery which can run the pump continuously for over 7½ hours. These times are based on continuous
pumping at 8' (2.4 mm) of static head. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battery.
Follow these recommendations:
• Use a B.C.I. size 27 deep-cycle battery, 175 minute reserve capacity, or larger
• Do NOT use a “maintenance-free” battery unless it is an AGM battery
• Replace your battery every 3 years
• Do not let corrosion build up on the battery terminals
• To check specific gravity, follow the instructions on a hydrometer (wet cell batteries only)
• Use of included plastic battery box is recommended to keep battery safe and clean.
PROTECT YOUR WARRANTY:
• Water level in batteries must be checked once a month (wet cell batteries only)
THE AQUANOT
®
BATTERY
© Copyright 2016 Zoeller
®
Co. All rights reserved.
DECLARATION OF CONFORMITY
Zoeller Pump Company declares under our sole responsibility that the Aquanot Model 508 to which this declaration relates, is in conformity with the Council Directives
on the approximation of the laws of the EC Member States relating to:
•
Electrical equipment designated for use with certain voltage limits (Directive 2006/95/EC), standards used: EN 60335-1:2004+A1+A11+A12+A2+A13+A14
+A15 and EN 60335-2-29:2004+A2
•
Electromagnetic Compatibility (Directive 2004/108/EC), standards used: EN 55014-1:2006+A2:2011, EN 55014-2:2015, EN 61000-3-2:2014, EN 61000-3-3:2013
•
Restrictive and Hazardous Substances RoHS (Directive 2011/65/EU), standards used: EN 50581-2012
•
Waste Electrical and Electronic Equipment WEEE (Directive 2012/19/EU)