12 VOLT DC BATTERY BACKUP PUMP

INSTALLATION INSTRUCTIONS

PREINSTALLATION CHECKLIST 

1.  Inspect your pump. Occasionally, products are damaged during shipment. If the unit or any of the parts are damaged, contact your dealer before using.
2.  Read all the installation instructions regarding installing and start up. Retain for future reference.

SEE BELOW FOR 

LIST OF WARNINGS

1.  Testing for Ground. As a safety measure each electrical outlet should 

be checked for ground using an Underwriters Laboratory listed circuit 

analyzer, which will indicate if the power, neutral and ground wires are 

correctly connected to your outlet. If they are not, call a qualified, licensed 

electrician.

2.  For your protection always disconnect the power supply from its power 

source before handling the components of your DC backup pump or the 

primary pump.

3.  Installation and checking of electrical circuits and hardware should be 

performed by a qualified, licensed electrician. 

4.  All electrical and safety codes must be followed in addition to the National 

Electrical Code and all applicable local codes. 

5.  

It is the owner’s responsibility to check the battery and battery 

connection at least once a month. Batteries contain acid and 

caution must be taken when handling.

6.  Risk of electric shock - These pumps have not been investigated for use 

in swimming pool areas.

7.  According to the state of California (Prop 65), this product contains 

chemicals known to the state of California to cause cancer and birth 

defects or other reproductive harm.

1.  Make sure there is a properly grounded 115V/230V receptacle available. 

Do not use primary pump circuit. The location must be within 6' of the 

control box and battery. The power supply for your DC control system 

plugs directly into the 115V/230V outlet. DO NOT USE AN EXTENSION 

CORD.

2.  Make sure the 115V/230V electrical supply circuit is equipped with 

fuses or circuit breakers of proper capacity.

3.  DC emergency pumps are designed for handling clear water. Do not use 

in septic tanks to pump effluent or sewage pits to pump sewage.

4.  Repair and service of your DC backup system should be performed by 

an authorized service station.

5.  The installation of DC automatic backup pumps requires the use of a 

variable level float switch for operation. It is the responsibility of the 

installing party, to ensure that the float switch will not hang up on the 

pump apparatus or pit peculiarities and is secured so the pump will turn 

“on” and “off”. It is recommended that the pit be 18" (457 mm) in diameter 

or larger to accommodate both a primary and a DC backup pump.

6.  For indoor use only.
7.  Installation and maintenance of this appliance is not intended for 

persons (including children) with reduced physical, sensory or mental 

capabilities, or lack of experience or knowledge, unless they have been 

given supervision or instruction concerning use of the appliance by a 

person responsible for their safety.

CAUTION

SEE BELOW FOR 

LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

CAUTION

  Turbulence caused by high velocity incoming water 

can cause sump pumps to airlock. If this condition exists, the incoming 

water must be baffled to avoid excessive turbulence.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:

  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:

  3649 Cane Run Road  • Louisville, KY  40211-1961

(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:

www.zoeller.com

®

Your Peace of Mind is Our Top Priority

 

®

ANY

 CHANGES MADE 

TO 

THIS DOCUMENT

 ALSO MA

Y

 AFFECT

 

FM131

1f & FM131

1s, HF1312, FM1

139 & FW0477 FOR F&W

.

© Copyright 2016 Zoeller

®

 Co. All rights reserved.

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

Patent No. D740329

Содержание AquaNot 508 Series

Страница 1: ...ontrol system plugs directly into the 115V 230V outlet DO NOT USE AN EXTENSION CORD 2 Make sure the 115V 230V electrical supply circuit is equipped with fuses or circuit breakers of proper capacity 3 DC emergency pumps are designed for handling clear water Do not use in septic tanks to pump effluent or sewage pits to pump sewage 4 Repair and service of your DC backup system should be performed by ...

Страница 2: ... and lower the water to the normal operating level and shut off b The yellow charging light should be on The charger is replacing the energy consumed during the test The green light will come on after the charger has replaced the energy consumed during the test 3 Adddistilledwatertobatterywhennecessaryperbatterymanufacturer s instructions CAUTION Battery acid is dangerous Take proper safety precau...

Страница 3: ...er precaution must be taken when handling Battery box will accomodate a maximum battery size of 13 342 mm Length x 7 178 mm Width x 9 241 mm Height BATTERY SELECTION The DC emergency pump is designed as a backup to your primary sump pump during unexpected power outages or primary pump failure The DC pump electronic controls and all the parts required for installation are included except the batter...

Страница 4: ...rimary sump pump and the control box should be on separate circuits 17 Reconnect power to primary sump pump 18 Optional A dongle may be used to input a name and number into the charger for service information to the end user 19 Optional On the bottom of the charger there is a pair of dry contacts to signal an auxiliary device of a low battery high water and reverse polarity alarm condition This si...

Страница 5: ...VEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP FIG 1 DC PUMP INSTALLED IN LINE WITH SUBMERSIBLE PUMP BATTERY BOX DC CHARGER OUTLET CHARGER R R BATTERY BOX OUTLET PRIMARY PUMP DC PUMP INSTALLED IN LINE WITH COLUMN PUMP IMPORTANT OFF LEVEL OF FLOAT ASSEMBLY MUST BE HIGHER THAN DC BACKUP PUMP 1 MIN OUTLET CHARGER DC CHARGER R R SK2959 SK2960 25 4 MM 25 4 MM ...

Страница 6: ...RGE TEE REDUCER FITTING CLAMP CHECK VALVE ASSEMBLY CLAMP BATTERY BOX 12 VOLT MARINE BATTERY SUPPLIED BY USER FIG 3 CLAMP WHITE LEAD TO POSITIVE BLACK LEAD TO DC PUMP WHITE LEAD TO POSITIVE BLACK LEAD TO NEGATIVE TO FLOAT WHITE LEAD 30 AMP FUSE DC CONTROL BOX BLACK LEAD TO NEGATIVE TO FLOAT SWITCH GREEN LEAD SPLICER FLOAT SWITCH DC PUMP ...

Страница 7: ...screen shows current alarms The cycle counter screen shows how many times the DC float has been activated The AC power loss counter screen shows how many times the AC power has been removed from the charger Optional a screen may also show the name and number of a service provider The 6 LED lights also display information about the charger at a glance The red AC power light will be on if AC power i...

Страница 8: ...arantee consistent quality A defective battery will never become fully charged and may damage the charging circuits of the Control It is for this reason that Zoeller offers its own line of batteries We offer both a Water Acid Deep Cycle Battery and maintenance free AGM battery which can run the pump continuously for over 7 hours These times are based on continuous pumping at 8 2 4 mm of static hea...

Отзывы: