background image

1

© Copyright 2020 Zoeller Co. All rights reserved.

 INSTALLATION INSTRUCTIONS 

912/915 24 x 24 Preassembled Sewage Systems

PREINSTALLATION CHECKLIST - ALL INSTALLATIONS

 

FM3291

1220

Supersedes

New

Notice to installer:  instructions must remain with installation.

1.    Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact  your dealer before using.  DO NOT remove the test 

plugs from the pump.

2.  Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained 

for future 

reference.

 

SEE BELOW FOR 

LIST OF WARNINGS

CAUTION

SEE BELOW FOR 

LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO

:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO

:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL

: (502) 778-2731 • 1 (800) 928-PUMP • 

FAX

: (502) 774-3624

Visit our website:

zoellerpumps.com

 1.  To reduce the risk of electrical shock, a properly grounded receptacle or 

control box must be installed in accordance with the governing codes.  Never 
remove ground pin from plug. 

  2.  Make certain that the ground fault interrupter protected receptacle or control 

box is within the reach  of the pump’s power supply cord.  DO NOT USE AN 
EXTENSION CORD. Extension cords that are too long or too light do not deliver 

sufficient voltage to the pump motor, and they could present a safety hazard if 

the insulation were to become damaged or the connection end were to fall into 
a damp or wet area.

  3.   Make sure the pump's electrical supply circuit is equipped with fuses or circuit 

breakers of proper capacity.  A separate branch circuit is recommended, sized 
according to the local  electrical codes for the current shown on the pump name 
plate.

  4.  

Testing for ground.

 As a safety measure, each electrical outlet should be 

checked for ground using a circuit analyzer which will indicate if the power, 
neutral and ground wires are correctly connected to your outlet.  If they are 

not, call a qualified, licensed electrician.

 5.  FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS POWER 

SOURCE BEFORE HANDLING.  If pump is wired direct, de-energize the circuit 
at the control box. Wear insulated protective shoes and do not stand in water.  
Pumps equipped with a 3-prong ground plug are designed to help protect 
against electrical shock. DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE 
THE GROUND PIN.    

  6.  Installation and servicing of the pump's electrical circuits and hardware should 

only be performed by a qualified, licensed electrician.

 7. 

Risk of electrical shock.

  Do not remove power supply cord and strain relief or 

connect conduit directly to the pump.  

  8.  Pump contains oil which becomes pressurized and hot when operating.  Allow 

2-1/2 hours after disconnecting before attempting service.

  9.  Pump is not intended for potable water due to possible contamination by oil 

contained in the pump.

 10. 

Risk of electric shock.

 These pumps have not been investigated for use in 

swimming pools and marine areas.

 11.  Prop65 Warning for California residents: 
 

: Cancer and  Reproductive Harm- 

        www.P65Warning.ca.gov.

  1.  This unit is not designed to handle any material other than human waste and 

toilet paper.  The list of items that should not be used with this system includes, 

but is not limited to, feminine sanitary products, condoms, cotton balls and 

swabs, baby wipes, paper towels, etc. 

 2.  Check to be sure your power source is capable of handling the voltage 

requirements of the motor, as indicated on the pump name plate.

  3.  The installation of variable level float switches is the responsibility of the 

installing party, and care should be taken that the tethered float  switch will 

not hang up on the pump apparatus or pit peculiarities and is secured so that 

the pump will shut off.  It is recommended to use rigid pipe and fittings and 

the pit be 18" or larger in diameter.

  4.  Vent hole.  It is necessary that all submersible sump, effluent, and sewage 

pumps capable of handling various sizes of solid waste be of the bottom intake 

design to reduce clogging and seal failures.  If a check valve is incorporated in 

the installation, a 3/16" vent hole must be drilled in the discharge pipe below the 

check valve and pit cover to purge the unit of trapped air.   Vent hole should be 

checked periodically for clogging.    The vent hole on a High Head application 

may cause too much turbulence. If you choose not to drill a vent hole, be sure 

the pump case and impeller is covered with liquid before connecting the pipe 

to the check valve. NOTE: THE HOLE MUST BE BELOW THE BASIN COVER 

AND CLEANED PERIODICALLY. Water stream will be visible when pump is 

operating.

  5.  Pump should be checked frequently for debris and/or buildup which may 

interfere with the float “on” or “off” position. Repair and service should be 

performed by Zoeller Pump Company Authorized Service and Warranty Center.

  6.  Maximum operating temperature for standard model pumps must not exceed 

130 °F. 

  7.  Do not operate a pump in an application where the Total Dynamic Head is 

less than the minimum Total Dynamic Head listed on the Pump Performance 

Curves.

   8.   For health reasons, do not unplug, turn off, or disable pump and use pump tank 

system as a way to fill up a sink or laundry tray, etc. 

9.  Pumps must be installed in accordance with the National Electrical Code 

and all applicable local codes and ordinances.  Pumps are not to be installed 

in locations classified as hazardous in accordance with National Electric Code, 

ANSI, NFPA 70.

NOTE: 

Pumps with the "UL" mark and pumps with the "US" mark are tested to UL 

standard UL778.  CSA certified pumps are certified to CSA standard C22.2 No. 108.

DATE INSTALLED:

MODEL NUMBER:

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

P/N 157026

Содержание 915

Страница 1: ...pressurized and hot when operating Allow 2 1 2 hours after disconnecting before attempting service 9 Pump is not intended for potable water due to possible contamination by oil contained in the pump...

Страница 2: ...derivatives oil gasoline solvents etc or other abrasive or corrosive substances wash towels or feminine sanitary products etc in all pumping applications The warranty set out in the paragraph above i...

Страница 3: ...loat mechanism s 6 Use a discharge pipe equivalent in diameter to the pump s discharge 7 Basin must be in accordance with governing codes and specifications 8 Pump must be level and float mechanism s...

Страница 4: ...MATERIAL REQUIREMENTS MINIMUM 4 COMPACTED SUB BASE NO HUB STYLE CONNECTOR 4 INLET PIPE INSTALLED BY CONTRACTOR MINIMUM 4 BACKFILL MATERIAL SEE REQUIREMENTS BELOW ROTOMOLDED BASIN AS PER ENGINEER S SPE...

Страница 5: ...electrical shock DO NOT UNDER ANY CIRCUMSTANCES REMOVE THE GROUND PIN The 3 prong plug must be inserted into a mating 3 prong grounded receptacle If the installation does not have such a receptacle i...

Страница 6: ...___________________________________________________________ __________________________________________________________________ __________________________________________________________________ ______...

Страница 7: ...___________________________________________________________ __________________________________________________________________ __________________________________________________________________ ______...

Страница 8: ...020 Zoeller Co All rights reserved MAIL TO P O BOX 16347 Louisville KY 40256 0347 SHIP TO 3649 Cane Run Road Louisville KY 40211 1961 502 778 2731 1 800 928 PUMP FAX 502 774 3624 Visit our website zoe...

Отзывы: