25. On a three valve bypass system, open the inlet and outlet valves and close the
bypass valve (see diagram).
26. Draw a two gallon bucket of water to be used in the brine tank.
27. Pour two gallon bucket of water into the brine tank.
28. Measure 1-1/2 oz of chlorine bleach and pour solution directly into the brine tank.
(Required on initial installations only.) Manually regenerate the softener by pressing
the extra cycle button for 8 seconds to run bleach through the softener.
29. Pour salt into compartment. Fill about 3/4 full initially. Do not pack full. This is also
where iron control salts will be put if you have rust stains.