background image

© Copyright 2014 Zoeller

®

 Co. All rights reserved.

1

FM2101

1014

Supersedes

0314

1. Inspect all materials. Occasionally, products are damaged during shipment. If the unit is damaged, contact your dealer before using.

2. Carefully  read  all  the  literature  provided  to  familiarize  yourself  with  specific  details  regarding  installation  and  use  before  attempting  the 

installation. These materials should be retained for future reference.                               

INSTALLATION INSTRUCTIONS

330 Series Centrifugal, Lawn Sprinkler Pumps

PREINSTALLATION  CHECKLIST  -  ALL  INSTALLATIONS

1 .  

To help reduce the risk of electrical shock, a proper ground or 

control box of grounding type must be installed and protected by 

a ground fault circuit interrupter (GFCI) in accordance with the 

National Electrical Code and applicable local codes.

2. 

 DO NOT USE AN EXTENSION CORD. Extension cords that are 

too long or too light do not deliver sufficient voltage to the pump 

motor. But more important, they could present a safety hazard if 

the insulation were to become damaged or the connection end 

were to fall into a damp or wet area. 

                      

3.  Make sure the pump’s electrical supply circuit is equipped with fuses or circuit 

breakers of proper capacity. A separate branch circuit, sized according to the 

National Electrical Code for the current shown on the pump name plate is 

recommended.

4. 

 TESTING FOR GROUND. As a safety measure, electrical  supply 

should be checked for ground using an Underwriters Laboratory 

Listed circuit analyzer which will indicate if the power, neutral and 

ground wires are correctly connected . If they are not, call a quali-

fied licensed electrician.   

                      

5. 

 Installation and checking of electrical circuits and hardware should 

only be performed by a qualified licensed 

 

electrician.

6. 

 FOR YOUR PROTECTION ALWAYS DISCONNECT PUMP FROM 

ITS POWER SOURCE BEFORE HANDLING.  De-energize the 

circuit at the control box. If the power point is out-of-sight, lock it 

in the open position and tag it to prevent unexpected application 

of power. Failure to do so could result in fatal electrical shock. 

7. 

Unit must be securely and adequately electrically grounded. This 

can be accomplished by wiring the unit to a ground metal-clad 

raceway system or by using a separate ground wire connected to 

the bare metal of the motor frame or other suitable means.

8. 

 Do not put a valve in the discharge line without automatic shut-off 

capability. Failure to install an automatic shut-off (pressure switch 

and tank) can allow the pump to run at no flow causing the pumped 

liquid to overheat and cause steam burns.

9. 

 Risk of electric shock. This pump has not been investigated for 

use in swimming pool areas.

10.Prop65 Warning for Califorania residents: Cancer and Reproductive Harm- 

www.P65Warnings.ca.gov.

NOTE: Repair and service should be performed by an Authorized Service Station 

only (Consult factory).

                                            

NOTE: Pumps are designed to have a maximum static lift (suction head) of 25 

feet (vertical distance from water surface to center line of pump).

NOTE: Pumps with the CSA CUS mark are tested to UL standard UL 778 and 

certified to CSA standard C22.2 No. 108.

1.   Check to be sure your power source is adequate to handle the 

amperage requirements of the motor as indicated on the pump or 

unit I.D. tag.

2.  All plumbing (discharge and intake lines) must be installed to 

meet local codes.

3.  Be certain the pump is completely primed before starting. Otherwise 

damage may occur to the seal.

4. 

 Be careful when touching the exterior of an operating 

motor - it may be hot enough to be painful or cause injury.

020293

CAUTION

SEE BELOW FOR LIST OF CAUTIONS

NOTE: THIS DOCUMENT DOES NOT CONTAIN THE NECESSARY LINKS TO PRINT PROPERLY. ALL LINKS 

WILL BE SUPPLIED BY F & W AND A PDF DOCUMENT WILL BE SUPPLIED. THE PDF DOCUMENT MUST BE 

USED TO PRINT FROM FOR ZOELLER USE. ANY CHANGES MADE TO THIS DOCUMENT MUST ALSO BE 

SENT TO F & W FOR PDF OUTPUT FOR OUR PRINTING NEEDS.

Notice to Installer: Instructions must remain with installation.

SEE BELOW FOR LIST OF WARNINGS

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL: (502) 778-2731 • 1 (800) 928-PUMP • FAX: (502) 774-3624

Visit our web site:

zoellerpumps.com

Register your 

Zoeller Pump Company 

Product on our website:

http://reg.zoellerpumps.com/

Содержание 330 Series

Страница 1: ... to prevent unexpected application of power Failure to do so could result in fatal electrical shock 7 Unit must be securely and adequately electrically grounded This can be accomplished by wiring the unit to a ground metal clad raceway system or by using a separate ground wire connected to the bare metal of the motor frame or other suitable means 8 Do not put a valve in the discharge line without ...

Страница 2: ...e For removal of the pump for service close the gate valve and disconnect the union CAUTION Do not use a globe valve or other restricting type of valve at the discharge This will seriously restrict the capacity of the pump LIMITED WARRANTY Zoeller Pump Company warrants to the purchaser and subsequent owner during the warranty period every new Zoeller Pump Company product to be free from defects in...

Страница 3: ...r Amps Max Liquid Temp Max Suction Lift Single Phase 115V 230V 3 4 Single Ph 115 230 60 3450 115V 14 0 7 0 180 F 25 ft 1 230V 18 0 9 0 1 1 2 21 0 10 5 2 25 0 12 5 Suction lift varies depending upon elevation altitude and water temperatures TYPICAL INSTALLATIONS IL0176 To Sprinkler System 1 1 2 in Discharge Pipe Gate Valve Unions Discharge Tee Priming Plug Pump Well Well Seal Foot Valve with Screen...

Страница 4: ... 1 This unit is not water proof and is not intended to be used in showers saunas or other potentially wet locations The motor is designed to be used in a clean dry location with access to an adequate supply of cooling air Ambient temperature around the motor should not exceed 104F 40C For outdoor installations motor must be protected by a cover that does not block airflow to and around the motor T...

Страница 5: ... reassemble the remainder of the pump NOTE Because damage to the shaft seal is most likely to occur in disassembly a new seal is required MOTOR DATA Figure 8 HP Phase Volts Code Letter Max Amps Locked Rotor Amps 3 4 3 4 1 1 115 230 K K 14 00 7 00 52 0 26 0 1 1 1 1 115 230 L L 18 00 9 00 70 0 39 0 1 1 2 1 1 2 1 1 115 230 J J 21 00 10 50 98 0 49 0 2 2 1 1 115 230 H H 25 00 12 50 116 0 58 0 OPERATION...

Страница 6: ... Copyright 2014 Zoeller Co All rights reserved 6 ...

Страница 7: ... 4 4 Ring Square Cut 133261 1 1 1 1 5 Seal Rotary w Spring 131100 1 1 1 1 6 Impeller Plastic P Models 133646 135620 134794 6 Impeller Brass B Models 133255 7 Diffuser 136469 1 1 1 1 8 Hex Hd Cap Screws 1 4 x 1 2 2 2 2 9 Rubber Diffuser 133260 1 1 1 1 10 Pump Body 020291 1 1 1 1 11 Hex Hd Cap Screws 7 16 x 1 4 4 4 4 12 Base 134217 1 1 1 1 13 Hex Hd Cap Screws 3 8 x 1 2 2 2 2 2 Standard Hardware Ite...

Страница 8: ...e is closed and priming 4 Open air has nowhere to go 5 Suction line or valve is closed 5 Open 6 Pump is down 6 Replace worn parts 7 Foot valve is leaking 7 Replace foot valve 8 Suction screen clogged 8 Clean or replace Loss of suction 1 Air leak in suction line 1 Repair or replace 2 Suction lift too high 2 Lower suction lift install foot valve and prime 3 Insufficient inlet pressure or suction hea...