background image

© Copyright 2012 Zoeller Co. All rights reserved.

  STEP 2 

Final Assembly

 

NOTE: External plumbing con

-

figuration will vary depending 

on the location of basin, location 

of main stack and available 

space.

  Place the basin assembly in its final 

position and complete plumbing. 

Secure all connections shown in 

Figure 2.

Illustrated Parts Breakdown

*When ordering this item, order the hardware pack item #6.

MODEL 132

Rev. A

Rev. B

ITEM DESCRIPTION

QTY

08/02

thru

12/10

01/11

thru

Current

Drain Pump

1

132-0001 132-0001

2

M72 (See FM1722)

1

72-0001

72-0001

Basin - Tank

1

013017

013017

4

Discharge Tube

1

013732

150861

Basin - Lid

1

013018

013018

6

Hardware Pack

1

013731

013731

Basin Seal

1

N/A*

N/A*

Unicheck

1

30-0181

019768

¼ - 20X1" lg. RHM Screw S.S.  

8

N/A*

N/A*

10 

¼ - Flat Washer S.S.      

16

N/A*

N/A*

11 

¼ - 20 Hex. Hd. Nut - S.S.

8

N/A*

N/A*

12

Pipe Cap w/o-ring 

1

N/A*

N/A*

13

O-Ring

1

N/A*

N/A*

SK2832

REV. "A"

REV. "B"

1

9

10

11

2

6

3

5

7

8

4

12

13

Figure 2

Drain Pump 132

SK2833

  STEP 3 

Initial Testing of Drain Basin System

1.  Plug the cord into a properly grounded GFCI receptacle.

2.  Fill the basin with 2-3 gallons of water and let sit for 3-4 

minutes to enable the environmentally safe peanuts to begin 

dissolving.

3.  Slowly fill the basin with water.

4.  Check all plumbing for leaks as the basin fills.

5.  Verify that the pump starts and stops.

6.  Check the discharge line for leaks as the pump empties 

the basin.

7.  Repeat steps 2 through 6 as necessary to ensure proper 

operation.

8.  If problems persist, refer to the troubleshooting guide 

located on page 2 of this manual.

Содержание 132

Страница 1: ... fault circuit interrupter GFCI in accordance with national electrical code and local codes 6 Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician 7 Risk of electric shock These pumps have not been investigated for use in swimming pool areas 8 According to the state of California Prop 65 this product contains chemicals known to ...

Страница 2: ... every new product to be free from defects in material and workmanship under normal use and service when properly used and maintained for a period of one year from date of purchase by the end user or 18 months from date of original manufacture of the product whichever comes first Parts that fail within the warranty period one year from date of purchase by the end user or 18 months from the date of...

Страница 3: ...llation of the drain system The actual configuration will vary depending on your cabinet and sink configuration Figure 1 STANDARD INSTALLATION 1 DO read all installation material included with the pump 2 DO inspect unit for any visible damage caused by shipping Contact dealer if unit appears to be damaged 3 DO always disconnect pump from power source before handling DO always connect to a separate...

Страница 4: ...n Seal 1 N A N A 8 Unicheck 1 30 0181 019768 9 20X1 lg RHM Screw S S 8 N A N A 10 Flat Washer S S 16 N A N A 11 20 Hex Hd Nut S S 8 N A N A 12 Pipe Cap w o ring 1 N A N A 13 O Ring 1 N A N A SK2832 REV A REV B 1 9 10 11 2 6 3 5 7 8 4 12 13 Figure 2 Drain Pump 132 SK2833 STEP 3 Initial Testing of Drain Basin System 1 Plug the cord into a properly grounded GFCI receptacle 2 Fill the basin with 2 3 g...