DRAIN PUMP SYSTEMS 

MODELS 104*, 105, 106, 110, 115, 120, 131

 INSTALLATION INSTRUCTIONS 

P/N 017583

FM2336

0520

Supersedes

1019

Notice to Installer:  Instructions must remain with installation.

MODEL: ______________________

DATE CODE:  __________________

DATE INSTALLED:   _____________

When making changes to this FM, be sure to also make changes to the Spanish and French version and also the FW0107 

if  the  104  pump  is  changed. Also,  if  the  changes  will  affect  the  model  1104,  FM2366  for  Dayton  will  also  be  affected.

1.    Inspect your unit. Occasionally, products are damaged during shipment. If the unit is damaged, contact  your dealer before using.  

DO NOT 

remove 

the test plugs from the pump. 

2.    Carefully read the literature provided to familiarize yourself with specific details regarding installation and use. These materials should be retained for future reference. 

1.  To reduce the risk of electrical shock, a properly grounded receptacle 

of grounding type must be installed and protected by a ground fault 

circuit interrupter (GFCI) and in accordance with National Electrical 

Code and local codes. 

(SEE WARNING BELOW)

 

2.  Make certain that the receptacle is within the reach of the pump’s 

power supply cord. DO NOT USE AN EXTENSION CORD.  Extension 

cords that are too long or too light do not deliver sufficient voltage 

to the pump motor. But more important, they could present a safety 

hazard if the insulation were to become damaged or the connection 

end were to fall into the sump.

3.  Testing for Ground. As a safety measure, each electrical outlet should 

be checked for ground using an Underwriters Laboratory Listed circuit 

analyzer which will indicate if the power, neutral and ground wires 

are correctly connected to your outlet. If they are not, call a qualified 

electrician.

4.  For Added Safety. Pump must be connected to a 3-prong grounded 

outlet interrupter device (ground fault circuit interrupter).

5.

 

FOR YOUR PROTECTION, ALWAYS DISCONNECT PUMP FROM ITS 

POWER SOURCE BEFORE HANDLING. 

 

Single phase pumps are supplied 

with a 3-prong grounded plug to help protect you against the possibility 

of electrical shock.

 

 

DO NOT, UNDER ANY CIRCUMSTANCES, REMOVE 

THE GROUND PIN.

  

To reduce the risk of electrical shock, a properly 

grounded receptacle of grounding type  must be installed and protected 

by a ground fault circuit interrupter (GFCI) in accordance with national 

electrical code and local codes.

6.  Installation and checking of electrical circuits and hardware should 

only be performed by a qualified licensed electrician. 

7.  Risk of electric shock - These pumps have not been investigated for 

use in swimming pool areas.

8. 

 

Prop65 Warning for California residents: 

 

: Cancer and  Reproductive Harm- 

        www.P65Warning.ca.gov.

1.  Check to be sure your power source is adequate for handling the 

voltage requirements of the motor, as indicated on the pump or basin 

plate. 

2.  Make sure the pump electrical supply circuit is equipped with fuses 

or circuit breakers of proper capacity. A separate branch circuit is 

recommended, sized according to the National Electrical Code for 

the current shown on the pump name plate. 

3.  All plumbing (discharge and vent lines) must be installed to meet local 

codes. Unit must be vented.

 

DO NOT USE AN AUTOMATIC PLUMBING 

VENT DEVICE SIMILAR TO A "PRO-VENT". 

Some states require this 

product to be installed by a licensed plumber.

4.  Repair and service should be performed by Zoeller Pump Company 

Authorized Service Station only.

5.  CHECK VALVE MUST BE USED TO REDUCE UNNECESSARY CYCLING 

OF PUMP.  Check valve must be purchased separately on model 104 

only. 

6.  Dewatering pumps are not designed or intended for handling raw 

sewage. 

7.  Maximum operating temperature for 105-131 Drain Pumps must not 

exceed 130 °F (54 °C). 104 Drain Pumps are not to exceed 110 °F (43 

°C).

8.  For health reasons, do not unplug, turn off, or disable pump and use 

pump tank system as a way to fill up a sink or laundry tray, etc.

9.  Unit is designed for above ground installation only.

SEE BELOW FOR LIST OF WARNINGS

CAUTION

SEE BELOW FOR LIST OF CAUTIONS

REFER TO WARRANTY ON PAGE 2.

    Pumps with the “UL” mark and pumps with the “US” mark are tested to 

UL Standard UL778. CSA Certified pumps are certified to CSA Standard 

C22.2 No. 108.

Product information presented 

here reflects conditions at time 

of  publication. Consult factory 

regarding discrepancies or 

inconsistencies.

MAIL TO

:  P.O. BOX 16347 • Louisville, KY  40256-0347

SHIP TO

:  3649 Cane Run Road  • Louisville, KY  40211-1961

TEL

: (502) 778-2731 • 1 (800) 928-PUMP • 

FAX

: (502) 774-3624

Visit our website:

zoellerpumps.com

MEETS UPC 

COMPLIES WITH ASME A112.3.4 

AND CSA B45.9.

P/N 018535-E

* MODEL 104 IS NOT

  UPC APPROVED.

Содержание 104 Series

Страница 1: ...er GFCI inaccordancewithnational electrical code and local codes 6 Installation and checking of electrical circuits and hardware should only be performed by a qualified licensed electrician 7 Risk of electric shock These pumps have not been investigated for use in swimming pool areas 8 Prop65 Warning for California residents Cancer and Reproductive Harm www P65Warning ca gov 1 Check to be sure you...

Страница 2: ...you specific legal rights and you may also have other rights which vary from state to state Limited Warranty ELECTRICAL PRECAUTIONS Before servicing a pump always shut off the main power breaker and then unplug the pump making sure you are not standing in water and wearing insulated protective sole shoes Under flooded conditions contact your local electric company or a qualified licensed electrici...

Страница 3: ...m the basin and pump 4 DO always disconnect pump from power source before handling DO always connect to a separately protected and properly grounded ground fault protected circuit DO NOT ever cut splice or damage power cord DO NOT carry or lift pump by its power cord DO NOT use an extension cord Do s And Don t s For Installing A Unit 5 DO NOT use a discharge pipe smaller than the pump discharge si...

Страница 4: ...de Standard IMPORTANT Check local and state codes before using the internal trap option 1 1 Figure 1 1A and 1 1B are typical configurations for installation of the drain systems The actual configuration will vary depending on your cabinet and sink configuration NOTE If installing the internal trap record the x dimension it will be required in Step 4 INTERNAL TRAP COMPONENTS SUPPLIED BY OTHERS Figu...

Страница 5: ...DIRECTED TOWARD THE FLOAT Water stream will be visible from this hole during pump run periods IMPORTANT DISCHARGE PIPE PUMP DISCHARGE WEEP HOLE SK2002 STEP 3 Installation of the Gasket 3 1 Install the gasket into the gasket seat at the top of the basin refer to Figure 3 1 for details Figure 3 1 SK2972 SEAL DETAIL BASIN SEAL ENSURE NOTCHES LINE UP ...

Страница 6: ...llation Only 4 1 Cut the tailpipe to the dimension determined in Figure 4 1 4 2 Install the sink drain components to the lid as shown in Figure 4 2 4 3 Orient the lid assembly as shown in Figure 4 3 and secure the trap components HAND TIGHTEN the assembly to the lid at this time Adjustment will be required in Step 5 Note To ensure a proper water seal the extension must be installed as shown in the...

Страница 7: ...on shown in Figure 5 1 5 2 Install the lid components as shown in Figure 5 2 NOTE Pull excess cordage through the opening and install the cord seal as shown in Figure 5 3A Insure o ring is in the cap before installation 5 3 Place the basin assembly in its final position and complete plumbing Secure all connections shown in 5 3A or 5 3B STEP 6 Initial Testing of Drain Basin System 6 1 Plug the cord...

Страница 8: ...8 115V 1 N A N A N A N A N A M98 007921 N A 1 N A N A N A N A N A M98 35 cord 150116 N A Replacement pump M72 115V 1 N A N A N A N A N A N A M72 72 0001 Replacement pump M63 115V 1 N A M63 63 0009 N A N A N A N A N A 2 Basin Tank 1 013017 013017 013017 013017 013017 013017 013017 3 Discharge Pipe 1 013732 013732 013732 013732 013732 014759 013732 4 Basin Cover 1 013018 013018 013018 013018 013018 ...

Отзывы: