2. Tools
3. Safety Cautions
S.N.
Name
Purpose
Picture
1
Cable stripping knife
For stripping the electrical insulation of cable
2
Wire stripper
For stripping the electrical insulation of wire
3
Power drill
(with 10-11 mm drill bit)
For drilling mounting holes on the ground
4
PH2 cross-head screwdriver For disassembling the bottom cover of the cabinet
5
Hex socket set
(with ratchet handle)
For connecting the power cable of the product
6
Level staff
For measuring the levelness of the equipment
7
Insulating mat
For placing parts during installation of the
equipment
8
2B pencil
For marking hole locations
9
Multimeter
For check before and upon electrification
10
Ladder
For installing a hanger at height to fix the energy
storage equipment
11
Tape measure
For measuring the height of the mounting plate and
the base from the ground upon wall mounting
12
Wire crimper
For crimping the input terminal
13
Copper lug crimper
For crimping the power inlet wire
14
Ethernet cable crimper
For crimping communication cable
Note: It is recommended that for on-site installation, a full set of No. 4-5 screwdriver sockets be provided.
(1) It is required to observe safety management regulations of the construction site upon entry.
(2) To enter the construction site, one shall wear a sturdy safety helmet properly (with the strap well fastened), and
avoid loose clothes and slippers. Working under influence of alcohol or smoking on construction site are not permitted.
(3) When operating at height: safety helmet shall be well fastened, safety belt shall be used properly, working tools shall
be firmly attached, and wear non-slip shoes.
(4) It is required to wear mask in case of heavy dust or painting operation.
(5) entering of hoisting areas or other dangerous areas is prohibited. Do not get under any vertical operations.
(6) Keep a safe distance from mechanical equipments and electrical lines to avoid mechanical and electrical injury.
(7) Workers using mobile electric tools are required to master use of the tools and observe precautions, wear insulting
shoes and gloves, and have metal housing well grounded or connected to the neutral for protection.
(8) For temporary access to electricity on site, the electrical box shall be kept in good conditions, and damaged electrical
components must be timely replaced.
(9) Rubber cable shall be used for temporary access to power on site. It is prohibited to use plastic twisted pair and to
insert the wire directly into a socket.
(10) Live-line work shall be avoided wherever possible.
(11) For operation in a foundation pit, on a roof, at any edge or in a hole, the operator shall be concentrated and be
cautious of possible falling objects.
(12) It is required to carefully observe environmental conditions and get aware of any present iron nails, steel bars on
the ground, so as to avoid puncture, collision, catching, falling or other injuries.
(13) Protective facilities, safety signs and warning plates on the construction site may not be removed without
permission.
(14) Construction equipment on site must be maintained and serviced to remain in sound conditions. Operation of faulty
equipment or excessive load is prohibited.
2
3