1.2 I Hydraulic connecti ons
•
The device will be connected with a Ø50 PVC pipe, using the half union connectors supplied (see § “5.1 I Descripti on”),
to the pool's fi ltrati on circuit, aft er the fi lter and before the water treatment.
•
Respect the directi on of hydraulic connecti on.
•
A by-pass must be installed to make it easier to work on the device.
: water entry valve
: by-pass valve
: water exit valve
: water entry adjustment valve
(opti onal)
: water exit adjustment valve
(opti onal)
: water treatment
* minimum distance
•
To evacuate the condensati on, fi t a Ø18 pipe on the grooved elbow mounted under the device base.
•
The elbow may be oriented to the rear or the side of the device.
Condensati on drainage orientati on
Tip: condensati on drainage
Cauti on, several litres of water must be drained from your device each day. We strongly recommend
connecti ng the drainage to the sewers