❶ Installati on
1.1 I Selecti ng the locati on
• The device must be installed at a minimum distance from the pool's surrounding edge.
This distance is determined by the electrical standards which apply in the installati on country.
• Do not lift the appliance using the casing, handle it from the base.
•
For outdoor installati on, provide free space around it (see § “1.2 I Hydraulic connecti ons”).
•
For indoor installati on, the device must be equipped with the plant room kit.
•
Install the 5 anti -vibrati on studs under the base and place the device on a stable, solid and level surface.
•
This surface must be able to bear the weight of the device (in parti cular in the case of installati on on a roof, a balcony
or any other support).
•
The device may be secured to the ground using the holes in the base of the device or with rails (not supplied). A
drilling scale is available on the back of the packaging carton.
: front
: rear
: connectors
: Anti -vibrati on studs
: Att achment holes
Bott om view of the appliance base for att achment to the ground and locati on of the
anti -vibrati on studs
The device must not be installed:
•
In a locati on subject to high winds,
•
With the blowing towards a permanent or temporary obstacle (window, wall, hedge, awning, etc.) less than 4 metres
away,
•
Within range of water or mud jets, sprays or run-off (take the eff ect of the wind into account),
•
Near a heat source or fl ammable gas,
• Near high frequency equipment,
•
In a locati on where it would be subject to snow build-up,
•
In a locati on where it might be fl ooded by the condensati on produced by the device when operati ng.
Tip: reduce any noise annoyance from your heat pump
• Do not install it under or towards a window.
•
Do not ti lt it towards your neighbours.
•
Install it in a clear space (the sound waves are refl ected on surfaces).
•
Install an acousti c screen around the heat pump, respecti ng the distances.
•
Install the anti -vibrati on studs under the heat pump and replace them regularly.
•
Install 50cm of fl exible PVC pipe at the heat pump water input and output (stops vibrati ons).