H0360700.D - EN - 2016-02
8
❸ Use
•
Never run the circulati ng pump (depending on the model) without water. The circulati ng
pump is very quiet when it starts up; you may not hear it running.
3.1 I Operati ng principle
Your heat pump uses the calories (heat) from your home's heati ng to heat up your pool's water.
The heat is exchanged through a series of pipes; the home's heati ng water circulates through the exchanger's body and
the pool water circulates through the pipes.
Tips: improve your pool's temperature rise and maintenance
•
Cover the basin with a sheet (bubble canopy, canvas, etc.) to prevent heat loss. The closer the heat source
is to the exchanger, and the exchanger is to the pool, the less heat will be lost.
•
Anti cipate the commissioning of your pool far enough in advance before you use it.
•
For the temperature rise, set the fi ltrati on pump to conti nuous operati on (24/24).
•
To maintain the temperature throughout the season, run "automati c" circulati on for at least 12 hours/
day (the longer this ti me the longer the appliance will have enough operati ng range to heat up)
3.2 User interface presentati on (depending on the models)
Display screen (default: water temperature measured)
"On/off " butt on
Value setti ng butt ons
Fixed
Flashing
Off
"On/off " light Appliance powered up
/
No electrical supply
Heati ng light
Heati ng in progress
•
Timed before operati on
•
No water circulati on in the secondary
circuit (less than 1.1m³/h)
No need for heati ng
Tips: using the user interface
•
The temperature is regulated by degrees.
•
Hold down the butt ons to scroll through the values quickly.
•
The setpoint adjustment range is between 2° and 40°C.
•
This maximum temperature may be lowered to protect the pool liner (see § “3.2.1 Modifying the
maximum setpoint”).
3.2.1 Modifying the maximum setpoint
•
Switch off the regulator (the "on" light goes off and the pool water temperature is displayed),
•
Press
and
simultaneously for 5 seconds: "PA" is displayed,
•
Press , then enter the value "80" with
or
(code to access the "parameters" menu),
•
Press to confi rm: "PA" is displayed,
•
Press
and
simultaneously for 5 seconds: "/1" is displayed,
•
Press
to scroll through each parameter unti l "r2" is displayed,
•
Press ; the current "r2" parameter value is displayed,
•
Press
or
to modify the maximum setpoint value, then press to validate this new value,
•
Press the
and
keys at the same ti me for 5 seconds to return to the pool water temperature display.