H0360700.D - EN - 2016-02
14
5.3 I Replacing the electrical box fuse (depending on the models)
•
CAUTION! Disconnect power to the appliance!
•
Remove the cover,
•
Disconnect the regulator,
•
Remove the regulator cover,
•
Remove the protecti ve fuse (T3,15AH250V).
5.4 I Wiring diagrams
CA
power cable: 2L+E 10/16A 3G1
TH
Regulati on thermostat with digital display
M1
Circulati ng pump motor
F1
3.15 A-T protecti on fuse
CD
Flow controller
So
Pool water regulati on sensor (PTC)
GN
Black duct
L1
"On/off " LED
L2
"Reg" LED fl ashing when ti med or fi xed heati ng in progress
S1
"On/off " switch
19-20
Dry command contact "normally open"
V-J
Green-yellow
Bl
blue
M
brown
B
White
N
black
Earth