Display

 

Designation

 

Cause

 

Solution

 

Reset

 

 

Communications'

 

defect

 

with

 

ventilation

 

card

 

A3

 

1.

 

Incorrect

 

connection

  

2.

 

Supply

 

defect

 

3.

 

incorrect

 

configuration

 

4.

 

card

 

out

of

order

 

1

 

and

 

2.

 

Check

 

connections

 

3.

 

check

 

the

 

position

 

of

 

switches

 

SW1

 

and

 

SW2,

 

and

 

the

 

JPC

 

bridge

 

1,

 

2,

 

3

 

and

 

4.

 

if

 

the

 

defect

 

persists,

 

contact

 

an

 

approved

 

technician

 

Switch

 

the

 

power

 

supply

 

off

 

or

 

automatic

 

reset

 

if

 

the

 

defect

 

disappears

 

 

5.2

 

Malfunctions

 

of

 

the

 

device

 

 

Dysfunction

 

Causes

 

Verification

 

/

 

solution

 

The

 

device

 

is

 

not

 

operational

 

No

 

display

 

Check

 

the

 

supply

 

voltage

 

and

 

the

 

fuse

 

F1

  

The

 

pool

 

temperature

 

is

 

above

 

the

 

set

point

 

temperature

 

Increase

 

the

 

set

point

 

temperature

 

A

 

message

 

is

 

displayed

 

on

 

the

 

screen

 

Check

 

the

 

meaning

 

of

 

message

 

§5.1

 

Absent

 

or

 

inadequate

 

water

 

flow

rate

 

Check

 

the

 

water

 

flow

rate

 

(by

pass,

 

filtration)

 

The

 

device

 

is

 

operational,

 

but

 

water

 

temperature

 

fails

 

to

 

rise

 

Inadequate

 

filtering

 

time

 

Set

 

the

 

filtering

 

system

 

to

 

manual

 

24

‐ 

hour

 

operation

 

for

 

temperature

 

control

 

Non

compliant

 

period

 

of

 

use

 

Check

 

that

 

outdoor

 

temperature

 

is

 

within

 

the

 

operating

 

range

 

(see

 

§1.3)

 

The

 

heat

 

pump

 

is

 

under

dimensioned

 

Check

 

the

 

characteristics

 

of

 

the

 

heat

 

pump

 

according

 

to

 

the

 

pool

 

The

 

automatic

 

pool

 

water

 

filler

 

is

 

blocked

 

in

 

the

 

open

 

position

 

Check

 

the

 

correct

 

operation

 

of

 

the

 

automatic

 

filler

 

The

 

heat

 

insulating

 

cover

 

is

 

not

 

used

 

Fit

 

the

 

heat

 

insulating

 

cover

 

The

 

evaporator

 

is

 

clogged

 

Clean

 

the

 

evaporator

 

(see

 

§4.1)

 

The

 

device

 

is

 

incorrectly

 

installed

 

The

 

device

 

must

 

be

 

installed

 

outdoors.

 

Check

 

that

 

there

 

is

 

no

 

obstacle

 

less

 

than

 

4

 

metres

 

from

 

where

 

the

 

blower

 

is

 

facing,

 

and

 

0.50

 

metres

 

behind

 

the

 

heat

 

pump.

 

The

 

fan

 

is

 

turning,

 

but

 

the

 

compressor

 

stops

 

from

 

time

 

to

 

time

 

without

 

an

 

error

 

message

 

appearing

 

The

 

heat

 

pump

 

does

 

defrost

 

cycles

 

from

 

time

 

to

 

time

 

This

 

is

 

normal

 

if

 

the

 

outdoor

 

temperature

 

is

 

below

 

10

 

°C

 

The

 

evaporator

 

is

 

clogged

 

Clean

 

the

 

evaporator

 

(see

 

§4.1)

 

The

 

heat

 

pump

 

breaker

 

opens

 

The

 

circuit

 

breaker

 

rating

 

is

 

too

 

low

 

or

 

inappropriate

 

Check

 

the

 

circuit

 

breaker

 

(see

 

§

 

2.5.3).

 

The

 

cable

 

cross

section

 

is

 

too

 

small

 

Check

 

the

 

cable

 

cross

section

 

(see

 

§

 

2.5.3)

 

The

 

supply

 

voltage

 

is

 

too

 

low

 

Call

 

your

 

electricity

 

provider

 

 

5.3

 

FAQ

 

 

Is

 

it

 

possible

 

to

 

improve

 

temperature

 

performance?

 

In

 

order

 

to

 

improve

 

the

 

efficiency

 

of

 

your

 

heat

 

pump

 

it

 

is

 

recommended

 

that

 

you:

 

protect

 

the

 

pool

 

with

 

a

 

cover

 

(floating

 

cover,

 

roller

 

cover,

 

etc.),

 

to

 

avoid

 

heat

 

loss

 

choose

 

periods

 

when

 

the

 

outside

 

temperature

 

is

 

warm

 

(on

 

average

 

>

 

10°

 

C)

 

in

 

order

 

to

 

facilitate

 

the

 

temperature

 

increase

 

(this

 

may

 

take

 

several

 

days.

 

The

 

actual

 

time

 

will

 

vary

 

according

 

to

 

weather

 

conditions

 

and

 

the

 

power

 

of

 

the

 

heat

 

pump)

 

the

 

higher

 

the

 

ambient

 

air

 

temperature,

 

the

 

more

 

efficient

 

the

 

heat

 

pump

 

will

 

be

 

keep

 

the

 

evaporator

 

clean

 

Check

 

that

 

filtration

 

time

 

is

 

sufficient

  

during

 

the

 

heating

 

phase,

 

water

 

flow

 

must

 

be

 

continuous

 

(24/24)

 

to

 

maintain

 

the

 

temperature

 

throughout

 

the

 

season,

 

allow

 

for

 

“automatic”

 

flow

 

of

 

at

 

least

 

12

 

hours/day

 

(the

 

longer

 

automatic

 

flow

 

is

 

used,

 

the

 

more

 

time

 

the

 

heat

 

pump

 

will

 

have

 

to

 

function

 

and

 

to

 

heat

 

the

 

water)

 

Setting

 

the

 

set

point

 

to

 

maximum

 

will

 

not

 

heat

 

the

 

water

 

any

 

faster

 

 

Содержание Power Force

Страница 1: ...EN Instructions for installation and use English H03619 00 D 2012 03...

Страница 2: ...ersonnel physically and mentally who are familiar with the operating instructions by reading the user guide Persons who do not satisfy these requirements must not handle the device so as to avoid expo...

Страница 3: ...ol panel messages 9 5 2 Malfunctions of the device 11 5 3 FAQ 11 6 Product registration 12 7 Conformity certificate 12 Available in appendix at the end of the manual wiring diagrams dimensions descrip...

Страница 4: ...cting an installation site The device must be installed outdoors and there must be adequate open space surrounding it see 2 4 the heat pump must be installed at a minimum distance from the end of the...

Страница 5: ...mp must pass via a protection and disconnection device not supplied complying with the standards and regulations in force in the country additional protection may be required during installation to gu...

Страница 6: ...s section of 2x1 5 mm or larger of type RO2V or equivalent in countries outside of the European Community with an outer diameter of between 8 and 13 mm Use the stuffing boxes supplied to run the cable...

Страница 7: ...o the instructions for the remote control unit for connections 3 Use 3 1 The control panel Symbol Designation steady flashing water flow water flow rate ok water flow too weak high or absent ambient a...

Страница 8: ...bled If valves 4 and 5 are not fitted open valve 1 completely and half close valve 3 power up the heat pump if the heat pump is on stand by press on for 3 seconds will appear for 2 seconds and for 3...

Страница 9: ...use a high pressure water hose ensure no foreign bodies obstruct the fan grid clean the evaporator with a soft brush and a fresh water jet disconnect the power cable do not twist or bend the metal bl...

Страница 10: ...installation technical file model code serial number maximum and minimum OT OP year of manufacture EC label manufacturer s address refrigerant and weight electrical parameters thermo dynamic and acou...

Страница 11: ...efect ST4 Sensor out of order or disconnected connector J8 on plate A1 Replace or reconnect the sensor Switch the power supply off or automatic reset if the defect disappears Defrost sensor defect ST3...

Страница 12: ...e is incorrectly installed The device must be installed outdoors Check that there is no obstacle less than 4 metres from where the blower is facing and 0 50 metres behind the heat pump The fan is turn...

Страница 13: ...tem The water treatment system chlorinator salt chlorinator etc must be installed preferably downstream from the heat pump see installation 2 4 and must be compatible with the latter check with the ma...

Страница 14: ...H03619 00 D1 EN 2012 03 1 Wiring diagram Power Force 25 35...

Страница 15: ...protection fuse F2 Internal compressor safety device F3 Electronic board protection fuse for regulation A1 F4 Electronic board protection fuse for ventilation A3 J1 Flow rate switch KA1 Pump relay KM...

Страница 16: ...and description Grid Display Pool water inlet 63 Pool water outlet 63 Evaporator Stuffing box Supply terminal board Electronic board Fuse F1 Condenser Compressor 4 way valve Dehydrator Liquid bottle...

Страница 17: ...H03619 00 D1 EN 2012 03 4 Power Force Weight Kg 25 35 205...

Страница 18: ...ler ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac pool Care Europe BP 90023 49180 St Barth l my d Anj...

Отзывы: