Why

 

is

 

my

 

heat

 

pump

 

not

 

heating?

 

on

 

start

up

 

the

 

device

 

remains

 

on

 

“pause”

 

for

 

3

 

minutes

 

before

 

actually

 

starting

 

up:

 

check

 

that

 

this

 

period

 

has

 

passed

 

once

 

the

 

pool

 

has

 

reached

 

the

 

set

point

 

temperature,

 

the

 

heat

 

pump

 

switches

 

off:

 

check

 

that

 

the

 

water

 

temperature

 

is

 

lower

 

than

 

the

 

requested

 

temperature

 

(see

 

§3.2)

 

if

 

the

 

water

 

flow

rate

 

is

 

zero

 

or

 

inadequate,

 

the

 

heat

 

pump

 

will

 

stop:

 

check

 

that

 

water

 

is

 

flowing

 

correctly

 

through

 

the

 

heat

 

pump,

 

and

 

check

 

the

 

hydraulic

 

connections

 

when

 

the

 

outdoor

 

air

 

temperature

 

drops

 

below

 ‐

12

 

°C,

 

the

 

heat

 

pump

 

will

 

stop:

 

check

 

the

 

outdoor

 

temperature

 

the

 

heat

 

pump

 

may

 

have

 

detected

 

a

 

malfunction:

 

check

 

if

 

an

 

error

 

code

 

is

 

displayed

 

on

 

the

 

screen,

 

if

 

so

 

refer

 

to

 

§5.1

  

If

 

the

 

problem

 

persists

 

after

 

you

 

have

 

checked

 

all

 

of

 

the

 

above

 

points:

 

contact

 

your

 

installer

 

Where

 

should

 

my

 

water

 

treatment

 

system

 

be

 

positioned

 

with

 

respect

 

to

 

the

 

heating

 

system?

 

The

 

water

 

treatment

 

system

 

(chlorinator,

 

salt

 

chlorinator,

 

etc.)

 

must

 

be

 

installed

 

preferably

 

downstream

 

from

 

the

 

heat

 

pump

 

(see

 

installation

 

§2.4),

 

and

 

must

 

be

 

compatible

 

with

 

the

 

latter

 

(check

 

with

 

the

 

manufacturer)

 

The

 

heat

 

pump

 

is

 

giving

 

off

 

water:

 

is

 

this

 

normal?

 

Your

 

heat

 

pump

 

will

 

give

 

off

 

water

 

in

 

the

 

form

 

of

 

condensation.

 

This

 

water

 

is

 

the

 

humidity

 

contained

 

in

 

the

 

air,

 

which

 

condenses

 

on

 

contact

 

with

 

certain

 

cold

 

components

 

inside

 

the

 

heat

 

pump.

  

Warning:

 

your

 

device

 

can

 

produce

 

several

 

litres

 

of

 

water

 

per

 

day.

 

 

6.

 

Product

 

registration

 

 

Register

 

your

 

product

 

using

 

our

 

website:

  

you

 

will

 

be

 

among

 

the

 

first

 

to

 

be

 

informed

 

of

 

new

 

Zodiac

 

products

 

and

 

special

 

offers,

 

You

 

can

 

help

 

us

 

to

 

constantly

 

improve

 

our

 

product

 

quality.

 

 

Australia

 

 

New

 

Zealand

 

www.zodiac.com.au

 

South

 

Africa

 

www.zodiac.co.za

 

Europe

 

and

 

rest

 

of

 

the

 

world

 

www.zodiac

poolcare.com

 

 

7.

 

Conformity

 

certificate

 

 

Z.P.C.E.

 

declares

 

that

 

the

 

following

 

products

 

or

 

ranges:

 

 

Swimming

 

pool

 

heat

 

pumps:

 

Power

 

Force

 

25

35

 

 

are

 

in

 

compliance

 

with

 

the

 

provisions

 

of:

 

 

the

 

ELECTROMAGNETIC

 

COMPATIBILITY

 

directive

 

2004/108/EC

 

 

the

 

LOW

 

VOLTAGE

 

directive

 

2006/95/EC

 

Содержание Power Force

Страница 1: ...EN Instructions for installation and use English H03619 00 D 2012 03...

Страница 2: ...ersonnel physically and mentally who are familiar with the operating instructions by reading the user guide Persons who do not satisfy these requirements must not handle the device so as to avoid expo...

Страница 3: ...ol panel messages 9 5 2 Malfunctions of the device 11 5 3 FAQ 11 6 Product registration 12 7 Conformity certificate 12 Available in appendix at the end of the manual wiring diagrams dimensions descrip...

Страница 4: ...cting an installation site The device must be installed outdoors and there must be adequate open space surrounding it see 2 4 the heat pump must be installed at a minimum distance from the end of the...

Страница 5: ...mp must pass via a protection and disconnection device not supplied complying with the standards and regulations in force in the country additional protection may be required during installation to gu...

Страница 6: ...s section of 2x1 5 mm or larger of type RO2V or equivalent in countries outside of the European Community with an outer diameter of between 8 and 13 mm Use the stuffing boxes supplied to run the cable...

Страница 7: ...o the instructions for the remote control unit for connections 3 Use 3 1 The control panel Symbol Designation steady flashing water flow water flow rate ok water flow too weak high or absent ambient a...

Страница 8: ...bled If valves 4 and 5 are not fitted open valve 1 completely and half close valve 3 power up the heat pump if the heat pump is on stand by press on for 3 seconds will appear for 2 seconds and for 3...

Страница 9: ...use a high pressure water hose ensure no foreign bodies obstruct the fan grid clean the evaporator with a soft brush and a fresh water jet disconnect the power cable do not twist or bend the metal bl...

Страница 10: ...installation technical file model code serial number maximum and minimum OT OP year of manufacture EC label manufacturer s address refrigerant and weight electrical parameters thermo dynamic and acou...

Страница 11: ...efect ST4 Sensor out of order or disconnected connector J8 on plate A1 Replace or reconnect the sensor Switch the power supply off or automatic reset if the defect disappears Defrost sensor defect ST3...

Страница 12: ...e is incorrectly installed The device must be installed outdoors Check that there is no obstacle less than 4 metres from where the blower is facing and 0 50 metres behind the heat pump The fan is turn...

Страница 13: ...tem The water treatment system chlorinator salt chlorinator etc must be installed preferably downstream from the heat pump see installation 2 4 and must be compatible with the latter check with the ma...

Страница 14: ...H03619 00 D1 EN 2012 03 1 Wiring diagram Power Force 25 35...

Страница 15: ...protection fuse F2 Internal compressor safety device F3 Electronic board protection fuse for regulation A1 F4 Electronic board protection fuse for ventilation A3 J1 Flow rate switch KA1 Pump relay KM...

Страница 16: ...and description Grid Display Pool water inlet 63 Pool water outlet 63 Evaporator Stuffing box Supply terminal board Electronic board Fuse F1 Condenser Compressor 4 way valve Dehydrator Liquid bottle...

Страница 17: ...H03619 00 D1 EN 2012 03 4 Power Force Weight Kg 25 35 205...

Страница 18: ...ler ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac pool Care Europe BP 90023 49180 St Barth l my d Anj...

Отзывы: