background image

H03619

00.D1.EN

 

 

2012/03

 

 

3

 

1.3

 

Operating

 

conditions

  

 

Operating

 

range:

 

 

air

 

temperature

 

of

 

between

 ‐

12

 

°C

 

and

 

38

 

°C,

 

 

water

 

temperature

 

of

 

between

 

10

 

°C

 

and

 

32

 

°C

 

,

  

 

 

Maximum

 

temperature

 

of

 

32°C

 

to

 

protect

 

the

 

pool

 

liner.

  

The

 

heat

 

pump

 

can

 

de

ice

 

by

 

forced

 

ventilation

 

or

 

a

 

reverse

 

cycle.

 

Fan

 

speed

 

will

 

vary

 

depending

 

on

 

ambient

 

conditions.

 

 

1.4

 

Technical

 

specifications

  

 

Power

 

Force

 

Voltage

 

Power

 

input*

    

Power

 

output*

 

Nominal

 

current

 

input*

 

COP*

kW

 

kW

 

A

 

25

 

400V

50Hz

 

5.7

 

25.5

 

10.6

 

4.5

 

35

 

400V

50Hz

 

7.9

 

35

 

12.9

 

4.5

 

 

*

 

with

 

ambient

 

air

 

at

 

+15

 

°C,

 

pool

 

water

 

at

 

26

 

°C,

 

and

 

relative

 

humidity

 

of

 

70%

 

(

 

according

 

to

 

French

 

standard

 

NF

414)

 

 

protection

 

class:

 

IP

 

24

 

 

refrigerant

 

gas:

 

R410A

  

 

refrigerant

 

charge:

 

see

 

product

 

information

 

plate

 

 

2.

 

Installation

 

 

 

Do

 

not

 

pick

 

up

 

the

 

device

 

using

 

the

 

outer

 

casing,

 

use

 

the

 

base.

 

 

2.1

 

Access

 

to

 

the

 

technical

 

compartment

 

 

   

 

 

 

 

 

 

2.2

 

Selecting

 

an

 

installation

 

site

 

 

 

The

 

device

 

must

 

be

 

installed

 

outdoors

 

and

 

there

 

must

 

be

 

adequate

 

open

 

space

 

surrounding

 

it

 

(see

 

§2.4).

 

 

 

the

 

heat

 

pump

 

must

 

be

 

installed

 

at

 

a

 

minimum

 

distance

 

from

 

the

 

end

 

of

 

the

 

pool

 

so

 

as

 

to

 

avoid

 

exposure

 

to

 

water

 

splashes.

 

The

 

appropriate

 

distance

 

should

 

be

 

defined

 

with

 

reference

 

to

 

the

 

national

 

electrical

 

standards

 

that

 

apply

 

in

 

the

 

country

 

of

 

installation.

 

 

the

 

heat

 

pump

 

must

 

not

 

be

 

installed:

  

near

 

a

 

source

 

of

 

heat

 

or

 

inflammable

 

gas,

  

near

 

a

 

road

 

with

 

the

 

risk

 

of

 

water

 

and

 

mud

 

splashes,

  

facing

 

a

 

strong

 

wind,

  

with

 

the

 

vent

 

facing

 

toward

 

a

 

permanent

 

or

 

temporary

 

obstacle

 

(window,

 

wall,

 

hedge,

 

etc…),

 

it

 

must

 

be

 

at

 

least

 

4meters

 

from

 

such.

  

 

2.3

 

Installing

 

the

 

device

 

 

 

install

 

the

 

4

 

stabilizing

 

brick

 

(supplied,

 

see

 

§1.2)

 

under

 

the

 

4

 

bases,

  

 

place

 

on

 

a

 

stable,

 

solid

 

(concrete

 

slab

 

type)

 

and

 

level

 

surface,

   

 

protect

 

from

 

risks

 

of

 

flooding

 

due

 

to

 

condensation

 

produced

 

by

 

the

 

device

 

during

 

operation

 

(see

 

§2.4)

 

 

 

The

 

heat

 

pump

 

can

 

be

 

fixed

 

to

 

the

 

ground

 

using

 

the

 

brackets

 

at

 

the

 

base

 

of

 

the

 

unit

 

(attachments

 

not

 

included).

 

 

Содержание Power Force

Страница 1: ...EN Instructions for installation and use English H03619 00 D 2012 03...

Страница 2: ...ersonnel physically and mentally who are familiar with the operating instructions by reading the user guide Persons who do not satisfy these requirements must not handle the device so as to avoid expo...

Страница 3: ...ol panel messages 9 5 2 Malfunctions of the device 11 5 3 FAQ 11 6 Product registration 12 7 Conformity certificate 12 Available in appendix at the end of the manual wiring diagrams dimensions descrip...

Страница 4: ...cting an installation site The device must be installed outdoors and there must be adequate open space surrounding it see 2 4 the heat pump must be installed at a minimum distance from the end of the...

Страница 5: ...mp must pass via a protection and disconnection device not supplied complying with the standards and regulations in force in the country additional protection may be required during installation to gu...

Страница 6: ...s section of 2x1 5 mm or larger of type RO2V or equivalent in countries outside of the European Community with an outer diameter of between 8 and 13 mm Use the stuffing boxes supplied to run the cable...

Страница 7: ...o the instructions for the remote control unit for connections 3 Use 3 1 The control panel Symbol Designation steady flashing water flow water flow rate ok water flow too weak high or absent ambient a...

Страница 8: ...bled If valves 4 and 5 are not fitted open valve 1 completely and half close valve 3 power up the heat pump if the heat pump is on stand by press on for 3 seconds will appear for 2 seconds and for 3...

Страница 9: ...use a high pressure water hose ensure no foreign bodies obstruct the fan grid clean the evaporator with a soft brush and a fresh water jet disconnect the power cable do not twist or bend the metal bl...

Страница 10: ...installation technical file model code serial number maximum and minimum OT OP year of manufacture EC label manufacturer s address refrigerant and weight electrical parameters thermo dynamic and acou...

Страница 11: ...efect ST4 Sensor out of order or disconnected connector J8 on plate A1 Replace or reconnect the sensor Switch the power supply off or automatic reset if the defect disappears Defrost sensor defect ST3...

Страница 12: ...e is incorrectly installed The device must be installed outdoors Check that there is no obstacle less than 4 metres from where the blower is facing and 0 50 metres behind the heat pump The fan is turn...

Страница 13: ...tem The water treatment system chlorinator salt chlorinator etc must be installed preferably downstream from the heat pump see installation 2 4 and must be compatible with the latter check with the ma...

Страница 14: ...H03619 00 D1 EN 2012 03 1 Wiring diagram Power Force 25 35...

Страница 15: ...protection fuse F2 Internal compressor safety device F3 Electronic board protection fuse for regulation A1 F4 Electronic board protection fuse for ventilation A3 J1 Flow rate switch KA1 Pump relay KM...

Страница 16: ...and description Grid Display Pool water inlet 63 Pool water outlet 63 Evaporator Stuffing box Supply terminal board Electronic board Fuse F1 Condenser Compressor 4 way valve Dehydrator Liquid bottle...

Страница 17: ...H03619 00 D1 EN 2012 03 4 Power Force Weight Kg 25 35 205...

Страница 18: ...ler ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac pool Care Europe BP 90023 49180 St Barth l my d Anj...

Отзывы: