H0361900.E - EN - 2015-02

1

•  

Read this notice carefully before installing, maintaining or repairing this appliance!

•  

The symbol 

 indicates important information that you must take into account to avoid the risk 

of damage to persons or the appliance.

•  

The symbol 

 indicates useful information as an indication.

  

 

 Warning

•  

As part of a continuous improvement process our products may be modified without prior notice. 

•  

Exclusive use: the heating of pool water (must not be used for any other purpose), 

•  

The appliance must be installed by a qualified technician, in compliance with the manufacturer’s 

instructions and in compliance with current local standards. The installer is responsible for the 

installation of the appliance and compliance with local regulations in matters of installation. Under 

no circumstances can the manufacturer be held liable in the event that local installation standards 

are not respected. 

•  

It is important that this appliance be handled by skilled and apt persons (physically and mentally) 

having received the instructions for use beforehand (by reading these instructions). All persons not 

meeting these criteria must not approach the appliance in order to avoid exposure to dangerous 

elements. 

•  

If the appliance suffers a malfunction: do not try to repair the appliance yourself, contact your 

reseller, 

•  

Before any intervention on the appliance, make sure it has been powered off and locked out, and 

that heating priority has been deactivated. 

•  

Before reconnecting any component, check that the voltage indicated on the device corresponds 

to the mains voltage.

•  

Eliminating or shunting any safety devices automatically voids the warranty, as does the replacement 

of parts using parts not originating from our warehouses.

•  

Do not release R410A coolant liquid into the atmosphere. This is a fluoride greenhouse effect gas 

covered by the Kyoto agreement with a global warming potential (GWP) = 1975 - (see the European 

Community regulations on fluoride greenhouse effect gases Directive EC 842/2006).

•  

Incorrect installation may cause damage to property or serious injuries (possibly causing death).

•  

Keep the appliance out of the reach of children.

•  

This heat pump is compatible with all types of water treatment.

Additional recommendations 

relative to pressurised appliances (PED-97/23/EC)

Installation and maintenance

•  It is prohibited to install the appliance close to combustible materials or close to the air intake on an adjacent 

building. 

•  For some appliances it is imperative to use the protection grate accessory if the installation is located in an 

unregulated access area.

•  During installation, repair, or maintenance operations it is prohibited to use piping as a step ladder: under 

stress the piping could rupture and the coolant could cause serious burns. 

•  During maintenance of the appliance the composition and condition of the heat transporting fluid will be 

checked as will the absence of traces of coolant. 

•  During the annual appliance seal inspection in compliance with applicable regulations, check that the high and 

low pressure switches are correctly connected to the refrigeration circuit and that they cut the electric circuit 

when triggered. 

•  During the maintenance phase make sure there are no traces of corrosion or oil stains around the refrigerating 

components. 

•  Before any operations on the refrigerating circuit it is imperative to shut down the appliance and to wait a few 

minutes before fitting temperature or pressure sensors. Some equipment such as the compressor and piping 

can reach temperatures in excess of 100°C and high pressures which can cause serious burns. 

Repairs

•  All welding operations are to be carried out by qualified welders 

•  Piping can only be replaced using copper tube in compliance with NF EN 12735-1 standard. 

•  Leak detection, pressure test:

 - never use oxygen or dry air, there is a risk of fire and explosion, 

 - use dehydrated nitrogen or a mixture of nitrogen and the coolant indicated on the identification plate, 

 - the test pressure on the low and high pressure sides must not exceed 42 bar.

•  For the high pressure circuit piping using copper pipes of a diameter = or > than 1’’5/8, a §2.1 certificate under 

standard NF EN 10204 is to be requested from the supplier and kept with the installation technical documents.

•  The technical information relative to the safety requirements for the different applicable directives is indicated 

on the identification plate. All this information must be recorded on the appliance installation manual which 

must be part of the installation technical file: model, code, serial number, maximum and minimum service 

voltage and service pressure, year of manufacture, CE marking, manufacturer’s address, coolant type and 

weight, electric parameters, thermodynamic and acoustic performances.

Содержание POWER FORCE Series

Страница 1: ...H0361900 E 2015 02 Instructions for installation and use English More documents on www zodiac poolcare com EN...

Страница 2: ...Installation and maintenance It is prohibited to install the appliance close to combustible materials or close to the air intake on an adjacent building For some appliances it is imperative to use the...

Страница 3: ...ectrical connections 4 3 Use 5 3 1 Presentation of the regulation 5 3 2 Starting up the appliance 6 3 3 Checks to perform after start up 7 3 4 Wintering 7 4 Maintenance 7 4 1 Maintenance instructions...

Страница 4: ...temperature setting of 32 C to protect the pool lining The heat pump can de ice by forced ventilation or a reverse cycle Fan speed will vary depending on ambient conditions 2 Installation Do not take...

Страница 5: ...l power grid with TT and TN S grounding systems Electrical protection circuit breaker curve D see 2 4 3 for ratings and with a 30 mA dedicated differential trip switch circuit breaker or switch Electr...

Страница 6: ...emperature Thanks to a dry contact without max I polarity 8 A Between terminals 1 2 Alarm Function connect a relay to the alarm terminal Thanks to a dry contact without max I polarity 2 A Between term...

Страница 7: ...On off button button to set and confirm parameters value setting buttons 3 1 1 Reading and changing parameters 3 1 2 Locking and releasing the key pad Press and for 3 seconds or 3 2 Starting up the a...

Страница 8: ...by pressing and holding the button for 3 seconds 3 4 Wintering Wintering is imperative failure to do so exposes the condenser to a risk of freezing this situation is not covered by the warranty To avo...

Страница 9: ...terminal board without power to the device Contact your electricity provider to find out if modifications have been made to your equipment Switch the power supply off or press Refrigerant circuit low...

Страница 10: ...l temperature is above the set point temperature A message is displayed on the screen Absent or inadequate water flow rate The parameter on off ctrl is on yes The air temperature is too low Check the...

Страница 11: ...rature see 3 2 If the water flow rate is zero or inadequate the heat pump will stop check that water is flowing correctly through the heat pump and check the hydraulic connections When the outside tem...

Страница 12: ...H0361900 E EN 2015 02 1 Electric diagram...

Страница 13: ...protection fuse F2 Internal compressor safety device F3 Electronic board protection fuse for regulation A1 F4 Electronic board protection fuse for ventilation A3 J1 Flow rate switch KA1 Pump relay KM2...

Страница 14: ...25 35 205 1 Grid 10 Condenser 2 Display 11 Compressor 3 Pool water inlet 63 12 4 way valve 4 Pool water outlet 63 13 Dehydrator 5 Evaporator 14 Liquid bottle 6 Stuffing box 15 HP switch 7 Supply term...

Страница 15: ...Notes...

Страница 16: ...ase contact your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac Pool Care Europe BP 90023 491...

Отзывы: