5.3 FAQ

Is it possible to 

improve temperature 

performance?

In order to 

improve the 

efficiency of 

your heat 

pump it is 

recommended 

that you:

•  Protect the pool with a cover (floating cover, roller cover, etc.), to avoid 

heat loss

•  Choose periods when the outside temperature is warm (on average 

> 10°C the night) in order to facilitate the temperature increase (this 

may take several days. The actual time will vary according to weather 

conditions and the power of the heat pump)

•  Keep the evaporator clean

Check that 

filtration time 

is sufficient 

•  During the heating phase, water flow must be continuous (24/24)

•  To maintain the temperature throughout the season, allow for 

“automatic” flow of at least 12 hours/day (the longer automatic flow is 

used, the more time the heat pump will have to function and to heat the 

water)

Setting the set-point to maximum will not heat the water any faster.

Why is my heat pump 

not heating?

•  On start-up the device remains on «pause» for 3 minutes before actually starting up: check 

that this period has passed

•  Once the pool has reached the set-point temperature, the heat pump switches off: check 

that the water temperature is lower than the requested temperature (see §3.2)

•  If the water flow-rate is zero or inadequate, the heat pump will stop: check that water is 

flowing correctly through the heat pump, and check the hydraulic connections

•  When the outside temperature drops below -12 °C, the heat pump will stop: check the 

outdoor temperature

•  The heat pump may have detected a malfunction: check if an error code is displayed on 

the screen, if so refer to §5.1 

•  If the problem persists after you have checked all of the above points: contact your 

installer

Where should my 

water treatment 

system be positioned 

with respect to the 

heating system?

•  The water treatment system (chlorinator, salt chlorinator, etc.) must be installed preferably 

downstream from the heat pump (see installation §2.4), and must be compatible with the 

latter (check with the manufacturer)

The heat pump is 

giving off water: is this 

normal?

•  Your heat pump will give off water in the form of condensation. This water is the humidity 

contained in the air, which condenses on contact with certain cold components inside the 

heat pump. 

•  Note: your device can produce several litres of water per day.

6. Registering the product

Register your product on our website: 

 

-

be the first to be informed of new Zodiac® products and special offers, 

 

-

help us to constantly improve our product quality.

Europe & Rest of the World

www.zodiac-poolcare.com

America

www.zodiacpoolsystems.com

Australia – Pacific

www.zodiac.com.au

Содержание POWER FORCE Series

Страница 1: ...H0361900 E 2015 02 Instructions for installation and use English More documents on www zodiac poolcare com EN...

Страница 2: ...Installation and maintenance It is prohibited to install the appliance close to combustible materials or close to the air intake on an adjacent building For some appliances it is imperative to use the...

Страница 3: ...ectrical connections 4 3 Use 5 3 1 Presentation of the regulation 5 3 2 Starting up the appliance 6 3 3 Checks to perform after start up 7 3 4 Wintering 7 4 Maintenance 7 4 1 Maintenance instructions...

Страница 4: ...temperature setting of 32 C to protect the pool lining The heat pump can de ice by forced ventilation or a reverse cycle Fan speed will vary depending on ambient conditions 2 Installation Do not take...

Страница 5: ...l power grid with TT and TN S grounding systems Electrical protection circuit breaker curve D see 2 4 3 for ratings and with a 30 mA dedicated differential trip switch circuit breaker or switch Electr...

Страница 6: ...emperature Thanks to a dry contact without max I polarity 8 A Between terminals 1 2 Alarm Function connect a relay to the alarm terminal Thanks to a dry contact without max I polarity 2 A Between term...

Страница 7: ...On off button button to set and confirm parameters value setting buttons 3 1 1 Reading and changing parameters 3 1 2 Locking and releasing the key pad Press and for 3 seconds or 3 2 Starting up the a...

Страница 8: ...by pressing and holding the button for 3 seconds 3 4 Wintering Wintering is imperative failure to do so exposes the condenser to a risk of freezing this situation is not covered by the warranty To avo...

Страница 9: ...terminal board without power to the device Contact your electricity provider to find out if modifications have been made to your equipment Switch the power supply off or press Refrigerant circuit low...

Страница 10: ...l temperature is above the set point temperature A message is displayed on the screen Absent or inadequate water flow rate The parameter on off ctrl is on yes The air temperature is too low Check the...

Страница 11: ...rature see 3 2 If the water flow rate is zero or inadequate the heat pump will stop check that water is flowing correctly through the heat pump and check the hydraulic connections When the outside tem...

Страница 12: ...H0361900 E EN 2015 02 1 Electric diagram...

Страница 13: ...protection fuse F2 Internal compressor safety device F3 Electronic board protection fuse for regulation A1 F4 Electronic board protection fuse for ventilation A3 J1 Flow rate switch KA1 Pump relay KM2...

Страница 14: ...25 35 205 1 Grid 10 Condenser 2 Display 11 Compressor 3 Pool water inlet 63 12 4 way valve 4 Pool water outlet 63 13 Dehydrator 5 Evaporator 14 Liquid bottle 6 Stuffing box 15 HP switch 7 Supply term...

Страница 15: ...Notes...

Страница 16: ...ase contact your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac Pool Care Europe BP 90023 491...

Отзывы: