background image

Pour plus de renseignements, merci de contacter votre revendeur.

For further information, please contact your retailer.

ZODIAC® is a registered trademark of Zodiac International, S.A.S.U., used under license.

Votre revendeur / your retailer

www.zodiac-poolcare.com

Zodiac P

ool Car

e Eur

ope - BP 90023 - 49180 St Barthélém

y d’

Anjou cede

x - S.

A.S.

U. au c

apit

al de 1 267 140 € / SIREN 395 068 679 / R

CS P

ARIS

Содержание POWER FORCE Series

Страница 1: ...H0361900 E 2015 02 Instructions for installation and use English More documents on www zodiac poolcare com EN...

Страница 2: ...Installation and maintenance It is prohibited to install the appliance close to combustible materials or close to the air intake on an adjacent building For some appliances it is imperative to use the...

Страница 3: ...ectrical connections 4 3 Use 5 3 1 Presentation of the regulation 5 3 2 Starting up the appliance 6 3 3 Checks to perform after start up 7 3 4 Wintering 7 4 Maintenance 7 4 1 Maintenance instructions...

Страница 4: ...temperature setting of 32 C to protect the pool lining The heat pump can de ice by forced ventilation or a reverse cycle Fan speed will vary depending on ambient conditions 2 Installation Do not take...

Страница 5: ...l power grid with TT and TN S grounding systems Electrical protection circuit breaker curve D see 2 4 3 for ratings and with a 30 mA dedicated differential trip switch circuit breaker or switch Electr...

Страница 6: ...emperature Thanks to a dry contact without max I polarity 8 A Between terminals 1 2 Alarm Function connect a relay to the alarm terminal Thanks to a dry contact without max I polarity 2 A Between term...

Страница 7: ...On off button button to set and confirm parameters value setting buttons 3 1 1 Reading and changing parameters 3 1 2 Locking and releasing the key pad Press and for 3 seconds or 3 2 Starting up the a...

Страница 8: ...by pressing and holding the button for 3 seconds 3 4 Wintering Wintering is imperative failure to do so exposes the condenser to a risk of freezing this situation is not covered by the warranty To avo...

Страница 9: ...terminal board without power to the device Contact your electricity provider to find out if modifications have been made to your equipment Switch the power supply off or press Refrigerant circuit low...

Страница 10: ...l temperature is above the set point temperature A message is displayed on the screen Absent or inadequate water flow rate The parameter on off ctrl is on yes The air temperature is too low Check the...

Страница 11: ...rature see 3 2 If the water flow rate is zero or inadequate the heat pump will stop check that water is flowing correctly through the heat pump and check the hydraulic connections When the outside tem...

Страница 12: ...H0361900 E EN 2015 02 1 Electric diagram...

Страница 13: ...protection fuse F2 Internal compressor safety device F3 Electronic board protection fuse for regulation A1 F4 Electronic board protection fuse for ventilation A3 J1 Flow rate switch KA1 Pump relay KM2...

Страница 14: ...25 35 205 1 Grid 10 Condenser 2 Display 11 Compressor 3 Pool water inlet 63 12 4 way valve 4 Pool water outlet 63 13 Dehydrator 5 Evaporator 14 Liquid bottle 6 Stuffing box 15 HP switch 7 Supply term...

Страница 15: ...Notes...

Страница 16: ...ase contact your retailer ZODIAC is a registered trademark of Zodiac International S A S U used under license Votre revendeur your retailer www zodiac poolcare com Zodiac Pool Care Europe BP 90023 491...

Отзывы: