10
2.3 I Operating
•
Check that there are no tools or other foreign objects in the machine.
•
The panel that provides access to the technical section must be put in place.
•
Set the valves as follows: valve B wide open, valves A, C, D and E closed
: water entry valve
: by-pass valve
: water exit valve
: water entry adjustment valve (optional)
: water exit adjustment valve (optional)
• An incorrect by-pass setting may cause the heat pump to malfunction.
•
Check that the hydraulic corrections are correctly tightened and that there are no leaks.
•
Check that the device is fully stable.
•
Set the water circulation running.
•
Close valve B gradually so that the filter pressure is increased by 150g (0.150 bars).
•
Open valves A, C and D fully then valve E by half (the air which has built up in the heat pump condenser and the
filtration circuit will bleed out). If valves D and E are not present, open valve A wide and close valve C by half.
•
Connect the power supply to the heat pump.
•
If the heat pump is on standby, press
, for 3 seconds ,
appears for 2
seconds then
(different software No. depending on the devices) for 3 seconds , and the water
and setpoint temperatures are displayed
, a 2 minute timer will start.
•
Set the temperature you want ("setpoint" temperature).
After the start-up steps for your heat pump:
•
Shut down the water circulation temporarily (by stopping the filtration or closing valve B or C) to check that you
device stops after a few seconds (via the activation of the flow rate controller).
•
Switch off the heat pump by pressing and holding for 3 seconds and check that it stops
.
2.4 I Additional user functions
2.4.1 Adjusting the temperature setpoint
• Press
to increase the temperature by 0.5 °C,
• Press
to reduce the temperature by 0.5 °C.
The heat pump stops automatically when the pool reaches the required temperature.
2.4.2 Locking/unlocking the keyboard
Press and hold
and
for 3 seconds:
or
.